Danfoss 018F6857 Solenoid Coil
Installation
AN283140309710en-000601 | 1
Solenoid coil
Type BB, BG, BQ, BT, BU, BY and BN
SEPECIFICATION
Type of control | 1 | |||
Class of protection | Class I | |||
Ambient temperature | See Tambient on coil | |||
Voltage variation
Voltage tolerances |
For voltage variation, see the print on the coil
For voltage tolerances, see the datasheet when ordering the coil |
|||
Humidity | Only non-conductive pollution occurs, except that occasionally a temporary conductivity caused by
Condensation is to be expected. |
|||
Ball pressure test | 200 °C (392 °F) | |||
Impulse withstand voltage |
Terminal box Cable
Spade |
4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <4000 m (13123 ft) 4.0 kV at altitude <4000 m (13123 ft) |
||
Plug | 4.0 kV at altitude <2000 m (6561 ft) | |||
3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft) | ||||
Overvoltage category | III | |||
Degree of protection IPXX Pollution degree PDX |
Enclosure rating according to IEC standard 60529, Pollution degree according to EN60664-1 |
IP67 plug | PD4 | |
IP65 plug
IP20 protection cap IP00 spade |
PD3 |
|||
Installation |
Integrated control (picture A – D) Incorporated control (picture A – D)
Independently mounted control (IP65 and IP67) (picture B – D) |
|||
Suitable cable and
Conductor size for the terminal box |
ø6.6 – ø11 mm (ø0.26 – ø0.43 in)
0.75 – 1.5 mm² (21 – 15 AWG flexible cord) |
|||
Suitable cable for the cable plug | See the datasheet when ordering the coil | |||
Moulded cable size
Cable conductor size |
Ø6.6 mm (ø0.26 in )
3 x 0.75 mm² (3 x 0.001 in2) |
|||
Moulded cable | The supply cord of this control cannot be replaced if the cord is damaged. The control should be discarded-
ed |
|||
Plugs can be removed/mounted | 10 times | |||
Surface temperature | Independently mounted controls should be sealed of if the coil temperature exceed higher than 85⁰C |
- Only qualified personnel is allowed to install or maintain this product
- Disconnect the power when dismounting the coil
- Avoid direct exposure to alkaline conditions; use in neutral conditions is recommended
- If the coil is used as an independently mounted control, the end-user shall use a plastic cable gland with strain relief
- Technical specifications are according to EN60730-1
ASSAMBLLY INSTRUCTION
CONTACT
Visit www.products.danfoss.com for further technical data
© Danfoss | Climate Solutions | 2021.12
Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB
Documents / Resources
![]() |
Danfoss 018F6857 Solenoid Coil [pdf] Installation Guide 32U1774.10, 18F58, 018F6857 Solenoid Coil, 018F6857, Solenoid Coil, Coil |