Danfoss-LOGO

Danfoss 018F6857 Solenoid Coil

Danfoss-018F6857-Solenoid-Coil-PRODUCT

Installation

AN283140309710en-000601 | 1
Solenoid coil
Type BB, BG, BQ, BT, BU, BY and BN

Danfoss-018F6857-Solenoid-Coil-FIG-1

SEPECIFICATION

Type of control 1
Class of protection Class I
Ambient temperature See Tambient on coil
Voltage variation

Voltage tolerances

For voltage variation, see the print on the coil

For voltage tolerances, see the datasheet when ordering the coil

Humidity Only non-conductive pollution occurs, except that occasionally a temporary conductivity caused by

Condensation is to be expected.

Ball pressure test 200 °C (392 °F)
 

 

Impulse withstand voltage

Terminal box Cable

Spade

4.0 kV at altitude <4000 m (13123 ft)

4.0 kV at altitude <4000 m (13123 ft)

4.0 kV at altitude <4000 m (13123 ft)

Plug 4.0 kV at altitude <2000 m (6561 ft)
3.1 kV 2000 m<altitude<4000 m (6561<altitude<13123 ft)
Overvoltage category III
 

Degree of protection IPXX Pollution degree PDX

 

Enclosure rating according to IEC standard 60529, Pollution degree according to EN60664-1

IP67 plug PD4
IP65 plug

IP20 protection cap IP00 spade

 

PD3

 

Installation

Integrated control (picture A – D) Incorporated control (picture A – D)

Independently mounted control (IP65 and IP67) (picture B – D)

Suitable cable and

Conductor size for the terminal box

ø6.6 – ø11 mm (ø0.26 – ø0.43 in)

0.75 – 1.5 mm² (21 – 15 AWG flexible cord)

Suitable cable for the cable plug See the datasheet when ordering the coil
Moulded cable size

Cable conductor size

Ø6.6 mm (ø0.26 in )

3 x 0.75 mm² (3 x 0.001 in2)

Moulded cable The supply cord of this control cannot be replaced if the cord is damaged. The control should be discarded-

ed

Plugs can be removed/mounted 10 times
Surface temperature Independently mounted controls should be sealed of if the coil temperature exceed higher than 85⁰C
  • Only qualified personnel is allowed to install or maintain this product
  • Disconnect the power when dismounting the coil
  • Avoid direct exposure to alkaline conditions; use in neutral conditions is recommended
  • If the coil is used as an independently mounted control, the end-user shall use a plastic cable gland with strain relief
  • Technical specifications are according to EN60730-1

ASSAMBLLY INSTRUCTION

Danfoss-018F6857-Solenoid-Coil-FIG-2

CONTACT

Visit www.products.danfoss.com for further technical data

© Danfoss | Climate Solutions | 2021.12

Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB

Documents / Resources

Danfoss 018F6857 Solenoid Coil [pdf] Installation Guide
32U1774.10, 18F58, 018F6857 Solenoid Coil, 018F6857, Solenoid Coil, Coil