CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module Instructions
CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module

Case

2×2 MIMO Case
Wiring Instruction

2TO1 2×2 MIMO Case
Wiring Instruction

4TO1 2×2 MIMO Case
Wiring Instruction
Wiring Instruction

Refer to the table below for Everon™ 6000 Parameters.

Symbol
Everon™ 6000 Parameters_Build 9_V1.

Release Version

SN Unit Version
1 RIU-TDD 23.4.1.11_Everon_6000_RIU_P2.V01.00.00.11
2 RIU-FDD 23.4.1.11_Everon_6000_RIU_P2.V02.00.00.05
3 DEU-25G 23.4.1.11_Everon_6000_DEU_P2.V01.00.03.87
4 DEU-10G 23.4.1.11_Everon_6000_DEU_P2.V02.00.03.
5 DCU 23.4.1.11_Everon_6000_DCU_P2.V01.00.03.83
6 dLRU-3.5 23.4.1.11_Everon_6000_dLRUH_P2.V01.00.04.92
7 dLRU-M 23.4.1.11_Everon_6000_dLRUM_P2.V02.00.04.06
8 dLRU-L 23.4.1.11_Everon_6000_dLRUL_P2.V02.00.04.03
9 dMRU-3.5 23.4.1.11_Everon_6000_dMRUH_P2.V01.00.03.51
10 dMRU-FDD 23.4.1.11_Everon_6000_dMRUF_P2.V02.00.00.46
11 dHRU-FDD 23.4.1.11_Everon_6000_dHRUF_P2.V01.00.01.68
12 System Version 23.4.1.11_Everon_6000_SYSTEM_P2.V01.04.03.38

LED Functionality and Color Definition

Optical LED definition

Green Amber
(SYNC) (LOS)
SFP Plug out SFP Plug out OFF OFF
Optic Link Fail 1. Optic cable disconnected OFF ON
2. SFP fail OFF ON
2.1 SFP fault OFF ON
2.2 SFP warning OFF ON
2.3 SFP alarm OFF ON
3. CPRI link down OFF ON
Optic Link OK 1. Optic cable connected ON ON
2. SFP OK ON ON
3. CPRI link down ON ON
CPRI Link OK 1. Optic cable connected ON OFF
2. SFP OK ON OFF
3. CPRI link up ON OFF

ALM/RUN/Power LED definition

LED Description Color
  ALM 1. Alarm Red
2. Device detect (Identify and is controlled from DCU) Red Flash (1Hz, 10s)
3. No alarm OFF
 RUN 1. The system is up and running Green Flash(1Hz)
2. Software or hardware failure OFF
 Power 1. Power on Green
2. Power off OFF

Caution message: The device is restricted use of unauthorized antennas, cables, and/or coupling devices which may cause device not conforming with ERP/EIRP limit and rf exposure requirement.
Warning : this device is license operation and not support home/personal use.

Warning! Each individual antenna used for this transmitter must be installed to provide a minimum separation distance as below or more from all persons and must not be co-located with any other antenna for meeting RF exposure requirements.
Warning! Antenna gain should not exceed as below.

Model No. distance antenna gain
dHRU-G2-6 5.7m 12.5dBi
dHRU-G2-7 7.7m 12.5dBi
dHRU-G2-85 5.3m 10dBi
dHRU-G2-19 5.4m 12.5dBi
dHRU-G2-17 6.6m 12.5dBi
dHRU-G2-23 3.8m 12.5dBi

WARNING ACCORDING TO PART 20
WARNING! This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use may result in significant forfeiture penalties, including  nalties in excess of $100,000 for each continuing violation.

Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC 28216 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2023 Corning Optical Communications. All rights reserved. LAN-3091-AEN / January 2023

CORNING Logo

Documents / Resources

CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module [pdf] Instructions
DHRU-G2-17, OJFDHRU-G2-17, OJFDHRUG217, DHRU-G2-17 HRU Digital High Power Amplifier Module, HRU Digital High Power Amplifier Module, Digital High Power Amplifier Module, High Power Amplifier Module, Power Amplifier Module, Amplifier Module, Module
CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module [pdf] User Guide
DHRU-G2-17, DHRU-G2-85, DHRU-G2-17 HRU Digital High Power Amplifier Module, HRU Digital High Power Amplifier Module, Digital High Power Amplifier Module, High Power Amplifier Module, Power Amplifier Module, Amplifier Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *