Continal 39011-DTSRF Quantum Dial Thermostat-RF
Our unique Quantum dial thermostat-RF is the only dial thermostat that can be operated remotely via an easy-to-use app or through its simple interface. Users appreciate its silent switching and clear LED indicator, while its self-learning feature requires minimal intervention.
Overlay information
For reference only. The image on the left explains the correlation between the temperature scale and the pairing scale. To be used for the initial set-up or in case of lost link error. Please keep the sticker on until installation is complete.
LED indication
* Only in offline mode
Note: When the thermostat is calling for heat, the LED will be OFF. If you encounter the lost link error, repeat the pairing procedure.
Installation
Jumper Feature Default
- PI*/SPAN TPI (jumper ON) or Span
- 0.5°C (remove jumper)
- TPI ON
- NSB** Night Setback ON (jumper
- ON) or OFF (remove jumper) ON
- Setback
- value
- -2°C (jumper ON) or -4°C
- (remove jumper)
- -2°C for heating
TPI will determine the pattern of your heating periods and will adjust it so that the temperature point will be maintained longer.
NSB will only operate if there is a master thermostat set on the wiring center. If there is no master set, there’s no need to remove the jumper.
- Make sure that the thermostat dial is set in position.
- Insert the batteries.
- If the Quantum dial thermostat-RF flashes green, but you need to re-pair it, read the Reset section.
Linking
Refer to the linking quick guides for instructions on how to link the Quantum wiring centre-RF.
This can be found at www.continal.eu/quantum
Identify (offline)
Identify (offline)
Factory reset
If a factory reset is required, each Quantum thermostat will need to be factory reset separately to the Quantum wiring centre.
Quantum dial thermostat-RFXPress the reset button for 5 seconds, then the thermostat will completely reset and remove itself from the ZigBee network.
Product compliance and safety information
Product compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU.
2405MHz-2480MHz; <14dBm (ZigBee)
Safety information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect your device before cleaning it with a dry cloth.
Note: Always isolate the AC mains supply before installing or working on any components that require 230 VAC supply.