(083.098)SSTA24A System Service Transition For Goodman
“
Specifications:
- Constructed of ASTM-A653 CS Type B Galvanized Steel
- Custom fit to the Aspen line of slab coils
- 26GA body and door with 30GA flange for easy fit around coil
and furnace - Sized for A-through-D Furnaces to fit CH24A through CH60B Aspen
Slab Coils - Flange: 1/8 overhang on each side, 1 high
- Access Door: Flush to body, size varies depending on model
Product Usage Instructions:
Furnace Sizing:
Refer to the chart below to match the appropriate Cody Model #
with the corresponding GDI Furnace Size (W1) and Aspen Coil Size
(W2).
Submittal Approval:
Fill out the Job, Location, and Engineer fields. Obtain approval
for construction before proceeding with installation.
Outside Dimensions (Inches):
Cody Model # | GDI Furnace Size (W1) | Aspen Coil Size (W2) | L | H |
---|---|---|---|---|
(083/098)SSTA24A | A(14) X CH24A(16) | 21 X 8 |
Note: W1 correlates with furnace opening, W2 correlates with
Aspen slab coil opening.
No:_________________________ Representative:_________________
By:_______________________
Title:_____________________
Date:_______________
4200 I 45, P.O. Box 1320, Ennis, TX 75120
Tel. 972-875-5884 Fax 972-875-0308
www.codycompany.com
FAQ:
Q: Can this SST be used with any other furnace or coil
brands?
A: No, the SST is custom fit specifically for the Aspen line of
slab coils.
Q: How do I determine the correct model for my furnace and coil
combination?
A: Refer to the chart provided in the user manual matching the
Cody Model # with your GDI Furnace Size and Aspen Coil Size.
“`
#083-#098
System Service Transition For Goodman
Furnace To Aspen Slab Coil
Horizontal Attic Install
Gas Heater/Attic
Horizontal Coil/Attic
SST
Constructed of ASTM-A653 CS Type B Galvanized Steel Custom fit to the Aspen line of slab coils (See in chart below for model #’s and sizing)
26GA body a nd door with 30GA f la nge for ea sy fit a round coil a nd furna ce
Access door is insulated and sealed with handle and break-away locks Lined with R6 1.5″(#083) or R8- 2″(#098) ductboard insulation Used in horizontal applications
Sized for A-through-D Furnaces to fit CH24A through CH60B Aspen Slab Coils (See “DX
Treme CH Series Sla b Horizonta l Coils” spec sheet for specific sizing on sla b coils)
Flange: 1/8 ” overhang on each side. 1″ high.
L
W2
H
W1
Access Door: Flush to body, Size varies depending on model.
Furnace Sizing:
A=14″ B=17 ½” C=21″ D=24 ½”
Submittal Approval:
Job: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Location:____________________ Engineer:____________________
APPROVED for CONSTRUCTION:
Note: W1 correlates with furnace opening W2 correlates with Aspen slab coil opening
OUTSIDE DIMENSIONS (INCHES)
Cody Model #
GDI Furnace Size (W1) Aspen Coil Size (W2) L H
(083/098)SSTA24A
A(14″) X CH24A(16″) X 21 X 8
(083/098)SSTA24B36A
A(14″) X CH24B/CH36A(24″) X 21 X 8
(083/098)SSTB36B48A B(17.5″) X CH36B/CH48A(24″) X 21 X 8
(083/098)SSTB48B60A B(17.5″) X CH48B/CH60A(36″) X 21 X 8
(083/098)SSTC24B36A
C(21″) X CH24B/CH36A(24″) X 21 X 8
(083/098)SSTC48B60A
C(21″) X CH48B/CH60A(36″) X 21 X 8
(083/098)SSTD48B60A D(24.5″) X CH48B/CH60A(36″) X 21 X 8
(083/098)SSTD60B
D(24.5″) X CH60B(42″) X 21 X 8
PO No:_________________________ Job No:_________________________ Representative:_____________ _____
By:_______________________
Title:_____________________
Date:_______________
4200 I 45, P.O. Box 1320, Ennis, TX 75120 Tel. 972-875-5884 Fax 972-875-0308
www.codycompany.com
Sheet Metal- #083 #098 March 2025
Documents / Resources
![]() |
codycompany (083.098)SSTA24A System Service Transition For Goodman [pdf] Owner's Manual CH24A 16, CH24B-CH36A 24, CH36B-CH48A 24, CH48B-CH60A 36, CH60B 42, 083.098 SSTA24A System Service Transition For Goodman, 083.098 SSTA24A, System Service Transition For Goodman, Service Transition For Goodman, Transition For Goodman, Goodman |