#083-#098

System Service Transition For Goodman

Furnace To Aspen Slab Coil
Horizontal ­ Attic Install

Gas Heater/Attic

Horizontal Coil/Attic

SST

 Constructed of ASTM-A653 CS Type B Galvanized Steel  Custom fit to the Aspen line of slab coils (See in chart below for model #'s and sizing)
 26GA body a nd door with 30GA f la nge for ea sy fit a round coil a nd furna ce
 Access door is insulated and sealed with handle and break-away locks  Lined with R6 ­ 1.5"(#083) or R8- 2"(#098) ductboard insulation  Used in horizontal applications
 Sized for A-through-D Furnaces to fit CH24A through CH60B Aspen Slab Coils (See "DX
­ Treme CH Series Sla b Horizonta l Coils" spec sheet for specific sizing on sla b coils)

Flange: 1/8 " overhang on each side. 1" high.
L

W2

H

W1
Access Door: Flush to body, Size varies depending on model.
Furnace Sizing:
A=14" B=17 ½" C=21" D=24 ½"
Submittal Approval:
Job: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Location:____________________ Engineer:____________________
APPROVED for CONSTRUCTION:

Note: W1 correlates with furnace opening W2 correlates with Aspen slab coil opening

OUTSIDE DIMENSIONS (INCHES)

Cody Model #

GDI Furnace Size (W1) Aspen Coil Size (W2) L H

(083/098)SSTA24A

A(14") X CH24A(16") X 21 X 8

(083/098)SSTA24B36A

A(14") X CH24B/CH36A(24") X 21 X 8

(083/098)SSTB36B48A B(17.5") X CH36B/CH48A(24") X 21 X 8

(083/098)SSTB48B60A B(17.5") X CH48B/CH60A(36") X 21 X 8

(083/098)SSTC24B36A

C(21") X CH24B/CH36A(24") X 21 X 8

(083/098)SSTC48B60A

C(21") X CH48B/CH60A(36") X 21 X 8

(083/098)SSTD48B60A D(24.5") X CH48B/CH60A(36") X 21 X 8

(083/098)SSTD60B

D(24.5") X CH60B(42") X 21 X 8

PO No:_________________________ Job No:_________________________ Representative:_____________ _____

By:_______________________

Title:_____________________

Date:_______________

4200 I 45, P.O. Box 1320, Ennis, TX 75120 Tel. (972) 875-5884 Fax (972) 875-0308

www.codycompany.com

Sheet Metal- #083 #098 ­ March 2025

