CD3002 Sharpy Plus Moving Head Fixture

Specifications

  • Product Name: Sharpy Plus Aqua CD3002
  • Manufacturer: Claypaky
  • IP Rating: IP65
  • Control Options: DMX, Art-Net, Wi-Fi
  • Light Source: Lamp inside the fixture

Product Usage Instructions

1. Safety Information

It is important to carefully read and follow the safety
information provided in the manual. Ensure to keep the safety
information readily available for reference.

2. Unpacking and Preparation

When unpacking the Sharpy Plus Aqua CD3002, ensure all contents
are present as listed in the manual. Check for the Omega bracket,
lamp inside the fixture, IP65 connector, and Wi-Fi receiver.

3. Installation and Start-up

3.1 Installing the Fixture

Install the fixture on the floor using rubber feet or on a
truss, ceiling, or wall. Remember to use a safety cable when not
placed on the floor.

3.2 Connecting to the Mains Supply

Connect the power cable to the designated power input on the
fixture as shown in Fig. 6 and Fig. 7.

3.3 Connecting the Signal Control Line: DMX / Art-Net

Utilize the DMX or Art-Net control options for signal control.
Follow the connections as indicated in Fig. 8.

3.4 Switching on the Fixture and Basic Setup

To switch on the fixture, plug in the power connector and allow
the projector to reset the effects. Follow any on-screen
instructions that appear on the display.

FAQ

Q: Where can I find the digital version of the safety
information for Sharpy Plus Aqua CD3002?

A: The digital version of the safety information can be accessed
at www.claypaky.com.

Q: What is the IP rating of Sharpy Plus Aqua CD3002?

A: The Sharpy Plus Aqua CD3002 has an IP65 rating, making it
suitable for outdoor use with protection against dust and
water.

“`

ENGLISH

SHARPY PLUS AQUA CD3002
INSTRUCTION MANUAL
https://muzcentre.ru/

Page
2
3
4 4 4 5 5
7 7 8 9 11 12
13

INDEX Contents
1. Safety information
2. Unpacking and preparation
3. Installation and start-up 3.1 Installing the fixture 3.2 Connecting to the mains supply 3.3 Connecting the signal control line: DMX / Art-Net 3.4 Switching on the fixture and basic setup
4. Maintenance 4.1 Opening the covers 4.2 Periodical cleaning 4.3 Effect module removal 4.4 Rotating gobos 4.5 Battery removal
5. Dimensions

Congratulations on choosing a Claypaky product! We thank you for your custom. Please note that this product, as all the others in the rich Claypaky range, has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements.

1

1. SAFETY INFORMATION

EN

SAFETY INFORMATION IMPORTANT: Claypaky recommend you to carefully read and keep the safety information on this product, also

available in digital format at the following link: www.claypaky.com

Ref: [FIS01Z – Safety Information Sharpy Plus Aqua]

IT

INFORMAZIONI DI SICUREZZA IMPORTANTE: Claypaky raccomanda di leggere accuratamente e conservare le informazioni di sicurezza relative

a questo prodotto, sempre reperibili in versione digitale al seguente link: www.claypaky.com

Rif: [FIS01Z – Safety Information Sharpy Plus Aqua]

DE

INFORMATIONEN ZUR SICHERHEIT WICHTIG: Claypaky empfiehlt, die Sicherheitsinformationen bezüglich dieses Produkts genau zu lesen und

aufzubewahren. Sie sind in Digitalversion immer unter folgendem Link auffindbar: www.claypaky.com

Ref: [FIS01Z – Safety Information Sharpy Plus Aqua]

ES

INFORMACIONES DE SEGURIDAD IMPORTANTE: Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este

producto. Además, está disponible una versión digital de la misma en el siguiente enlace: www.claypaky.com

Ref: [FIS01Z – Safety Information Sharpy Plus Aqua]

FR

CONSIGNES DE SÉCURITÉ IMPORTANT: Claypaky recommande de lire attentivement et de conserver les informations de sécurité relatives à

ce produit, disponibles en version digitale au lien suivant: www.claypaky.com/download

Réf. : [FIS01Z – Safety Information Sharpy Plus Aqua]

RU

: Claypaky

, : www.claypaky.com

: [FIS01Z – Safety Information Sharpy Plus Aqua]

SHARPY PLUS AQUA

2

2. UNPACKING AND PREPARATION

1

Omega bracket

Lamp inside the fixture

IP 65 connector

Wi-fi receiver

Packing contents – Fig. 1

2

3

LOCKED

UNLOCKED

90°

90°

LOCKED

UNLOCKED

45°

45°

45°

45°

45°

90°

90°

45°

PAN Mechanism Lock and Release (every 90°) – Fig. 2 TILT Mechanism Lock and Release (every 45°) – Fig. 3

SHARPY PLUS AQUA

3

3. INSTALLATION AND START-UP 3.1 Installing the fixture
4

Light collimation system This product contains internal light collimation system. Avoid intense light from any angle.
Installing the projector – Fig. 4 The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall. WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point of the base.
3.2 Connecting to the mains supply
5

LCD Display Functional buttons
Control panel – Fig. 5
6
2
1
Connecting and disconnecting power cable – Fig. 6
SHARPY PLUS AQUA

Wi-Fi

DMX in

DMX out Ethernet

Power in

1 2
3

4

7
Mains

Connecting to the mains supply – Fig. 7
3.3 Connecting the signal control line: DMX / Art-Net 8

DMX 512 5 PIN
51 42
3

SCREEN SIGNAL SIGNAL

Connecting to the control signal line (DMX) – Fig. 8 Use a cable compliant to the EIA RS-485 specifications: 2-pole twisted, shielded, 120Ohm characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cables or other cables with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the shield braid and to pin 1 of the connectors.
3.4 Switching on the fixture and basic setup
9

Dmx Address

1

Warning Message

Switching on the projector – Fig. 9 Plug the power connector. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

Model SHARPY PLUS AQUA

Firmware Version X.X.X Date – Hour

xxx (Fixture ID) Dmx Address xxx

System errors E: ……………………. W: …………………….

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit – Tilt 128 bit). The control panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address. During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
F It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the key will be cancelled.

SHARPY PLUS AQUA

5

Continue

10
28

28

Reversal of the display – Fig. 10
B C To activate this function, press UP and DOWN keys simultaneously while the display is in the rest mode. This status will be memorised and
maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again. Setting the projector starting address On each projector, the starting address must be set for the control signal (addresses from 1 to 512). The address can also be set with the projector switched off. If there is no DMX input signal, the display will show “No signal”. IMPORTANT: If there is no DMX input signal the address displayed blinks.
Functions of the buttons – Using the menu
F Confirms the displayed value, or activates the displayed function, or enters the successive menu.
C Decreases the value displayed (with auto-repetitions) or passes to the next item in the menu.
DOWN
B Increases the value displayed (with auto-repetitions) or passes to the previous item in a menu. UP
D Return to the top level LEFT
E Commute from units, tens, hundreds, in the “Address” and “Calibration” menù.
RIGHT
USING THE MENU:
D 1) Press LEFT once ­ “Main Menu” appears on the display. B C 2) Use the UP and DOWN keys to select the menu to be used:
· Setup (Setup Menu): To set the setting options. · Option (Option Menu): To set the operating options · Information (Information Menu): To read the counters, software version and other information. · Manual Control (Manual control Menu): To trigger the test and manual control functions. · Test (Test Menu): To check the proper functioning of effects · Advanced (Advanced Menu): Access to the “Advanced menu” is recommended for trained technical personnel.
F 3) Press to display the first item in the selected menu. B C 4) Use the UP and DOWN keys to select the MENU items.
Setting addresses and options with the projector disconnected The projector DMX address, as well as other possible operating options, can also be set when the appliance is disconnected from the electricity supply.
E All that is needed is to press RIGHT to momentarily activate the display and thus access the settings. Once the required operations have been
carried out, the display will switch off again after a wait time of 30 seconds.

SHARPY PLUS AQUA

6

4. MAINTENANCE 4.1 Opening the covers

11

12

2 1

2
3 4

WARNING – IP66 fixture – Failure to completely remove power from fixture prior to servicing can lead to serious injury or death. For additonal service information please contact service@claypaky.it
IMPORTANT The screws to be removed have rubber sleeve gaskets at the threaded end of the screw. DO NOT LOOSE these. They must be reinstalled when reassembly is done. If these rubber sleeve gaskets are damaged, they must be replaced with exact original equipment (OE) parts, we also suggest to replace the rubber sleeve gasket every 2 years.
To maintain IP66 rating each cover has rubber gasket on it. If any rubber gasket is lost or damaged, it must be replaced by an original equipment (OE) part. We also suggest to replace the rubber sleeve gasket every 2 years.

SHARPY PLUS AQUA

7

Continue

4.2 Periodical cleaning

13

Upper Side

1

2
Lower Side

Periodical cleaning – Fig. 13
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The
frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the
working environment (air humidity, presence of dust, salinity, etc.).
Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors, from the lenses and filters. It is recommended
that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations: · General cleaning of internal parts. · Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Claypaky. · General visual check of the internal components, cabling, mechanical parts, etc. · Electrical, photometric and functional checks; eventual repairs. NOTE: keep a careful cleaning of the ”CMY/colour filters assembly” to prevent rapid deterioration.

SHARPY PLUS AQUA

8

4.3 Effect module removal 14
Lower side
1
2

Extraction of the effect modules – Fig. 14. IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 13, 14 and 15 in reverse order.

NOTE: – Do not disconnect wiring harnesses when the fixture is switched on, to avoid to damage electronic boards. – Do not switch on the fixture with wiring harness disconnected.

SHARPY PLUS AQUA

9

Continue

14

1 2

3 4

6 5
7

9
ADJUST
8

9
ADJUST

Lamp change – Fig 14.
Take the new lamp out of its package and insert it in the fitting. WARNING: do not touch the lamp envelope with bare hands. Should this happen, clean the bulb with a cloth soaked in alcohol and dry it
with a clean, dry cloth.
Lamp adjustment
To adjust the lamp position move the 2 screw as shown in the picture. WARNING: The lamp must be adjusted with the projector switched off. After adjusting, close the effect covers, switch on the projector and check
that the adjustment has been correctly made. If necessary, switch off the projector, remove the effects covers and repeat lamp adjustment. REMARK: – Lifetime of the lamp will be influenced by the switching cycle. – After a successful starting, attempt to keep the lamp burning for at least 15 minutes in order to complete the chemical cycle of the
lamp to secure the lifetime. – After switching-off the lamp wait at least 2 minutes before switching it on again.

SHARPY PLUS AQUA

10

15
1

4.4 – Rotating gobos
2

Gobo holder replacement – Fig. 15
16 COATED GLASS GOBOS

Grey/Black side away from lamp

Reflective side towards the lamp
Gobo orientation – Fig. 16 The picture shows the correct gobos orientation.

17

ROTATING GOBO

GOD01G-001 1st (Half Circle)

8th GOD01G-008 (Small Dots)

GOD01G-002 (Ripple)

2nd

INDEX

7th

GOD01G-007 (Broken Circle)

ø15.9 ±0.2 ø12 ±0.2

GOD01G-003 3rd (Fat Line)

6th GOD01G-006 (Grid)

GOD01G-004

4th

(Smooth Breakup)

5th GOD01G-005 (Multiple Moons)

Replacing rotating gobos – Fig. 17 – Original gobos have a special coating designed specifically to resist to high temperatures; – IMPORTANT The rotating gobo wheel only uses dichroic glass gobos. Do not use metal gobos. – For any additional information please contact Claypaky service center.

SHARPY PLUS AQUA

11

3 1.1
Continue

4.5 Battery removal 18
1 2

4 3

Battery removal – Fig. 18 This product contains a rechargeable battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force.

SHARPY PLUS AQUA

12

650 (25.59″)
513 (20.20″)

5. DIMENSIONS
731 (28.78″)

619 (24.37″)

336 (13.23″)

456 (18.03″)
420 (16.53″)

Cause and solution of problems

THE PROJECTOR WILL NOT SWITCH ON ELECTRONICS NON-OPERATIONAL DEFECTIVE PROJECTION REDUCED LUMINOSITY
POSSIBLE CAUSES
No mains supply. Lamp exhausted or defective. Signal transmission cable faulty or disconnected. Incorrect addressing. Fault in the electronic circuits. Lenses or reflector broken Dust or grease deposited.

PROBLEMS
CHECKS AND REMEDIES
Check the power supply voltage. Replace the lamp. (See instructions). Replace the cables. Check addresses (see instructions). Call an authorized technician. Call an authorized technician. Clean (see instructions).

SHARPY PLUS AQUA

13

SHARPY PLUS AQUA

14

SHARPY PLUS AQUA

15

IST021/001 ­ EN – Rev.0 01/2021

CLAYPAKY S.p.A. – Via Pastrengo, 3/b – 24068 Seriate (BG) Italy – Tel. +39-035 -654311 – www.claypaky.com