STEP 1
– Ensure power is turned off, or removed from board
– Carefully press in two tabs on one end of plastic case
– Pry case lid up and off circuit board. Set aside
STEP 2
– Remove daughterboard from packaging, and carefully insert it into either one of the two headers on main circuit board
– Ensure all 9 pins are properly seated into header, and daughterboard is straight up and down (not bent over)
STEP3
– Repeat for additional daughterboard, if desired
– Using case lid as a guide carefully route antenna wires to fit into slots on lid
– Re-install lid making sure wires are routed to avoid damage
– lid should snap onto tabs on ends
CAUTION !
Do not install or remove
Daughterboard(s) with unit powered.
Remove power first
Camden Door Controls 5502 Timberlea Blvd. Mississauga, Ontario L4W 217 |
|||