BROAN LogoTECHNICAL SPECIFICATIONS  
FG7T (E and N Series)BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - Logo 1

FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces

Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces
Induced Draft – 96% AFUE
Input 60,000 – 115,000 Btuh
The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces

FEATURES and BENEFITS

  • Variable Speed Direct Drive Blower: Energy-efficient, brushless DC (ECM) motor controls airflow to provide better temperature control, humidity control and air distribution.
  • SmartLite® Technology: Auto-adjusts igniter on time to extend igniter life.
  • Hot Surface Igniter: Innovative application of a silicon nitride type igniter.
  • 30 Second Blower Delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
  • 30 Second Post Purge: Increases life of heat exchanger.
  • 60 Second Fixed Cooling Cycle Blower-Off Delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil.
  • Color Coded Wire Harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Diagnostic Lights: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
  • Integrated Control Boards: With connections for electronic air cleaner, humidifier, and dehumidification.
    Ergonomically located for ease of service.
  • 2 Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels.
  • Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and stainless steel secondary heat exchanger assures a long life.
  • 100% Fired and Tested: All units and each component are tested on the manufacturing line.
  • Best Packaging in the Industry: Unique corner post design assures product will arrive to the homeowner dent free.
  • Flexible Category IV Venting System: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility (as an accessory).
  • Two Piece Door Design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
  • Sealed Vestibule: Reduces burner and inducer sound levels.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

LOCATION OF FURNACE COMPONENTS

BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - COMPONENTS

DIMENSIONS

*TE Model #’s Dimension “A” Dimension “B” Dimension “C”
060D-VB1 17 1/2 15 7/8 16 1/8
080D-VC1 21 19 3/8 19 5/8
100D-VC1
115D-VD1 24 1/2 22 7/8 23 1/8

NOTE: Dimensions shown in inchesBROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - DIMENSIONS 1

*TE Model #’s Dimension “A” Dimension “B” Dimension “C”
060D-VB1 17 1/2 15 7/8 16 1/8
080D-VC1 21 19 3/8 19 5/8
100D-VC1
115D-VD1 24 1/2 22 7/8 23 1/8

BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - DIMENSIONS 2

G7TE-080D-V35C1, VSHE (C CABINET)BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - CABINET 1

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

G7TN-060D-V24B1, VSHE (B CABINET)BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - CABINET 2

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

G7TN-080D-V35C1, VSHE (C CABINET)BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - CABINET 3

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

G7TN-115D-V45D1, VSHE (D CABINET)BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - CABINET 4NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

VENTING

All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.

FURNACE MODELS (BTU)

FURNACE INSTALLATION

SINGLE PIPE LENGTH (FT.)
with 1 long radius elbow**

DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe**

OUTLET OUTLET INLET/OUTLET INLET/OUTLET
2” Diameter 3” Diameter 2” Diameter 3” Diameter
60,000 Upflow 90 90 60 90
Downflow 30 90 30 90
80,000 Upflow 40 90 40 90
Downflow 30 90 30 90
100,000 Upflow 30 90 30 90
Downflow 30 90 25 90
115,000 Upflow N/A 90 N/A 90
Downflow N/A 90 N/A 90

*NOTES:

  1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
  2. Two 45 degree elbows are equivalent to one 90 degree elbow.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

MODEL IDENTIFICATION CODE

BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - MODEL IDENTIFICATION CODE

SPECIFICATIONS

 FG7TE MODEL NUMBERS  -080D-V35C1
Input – Btuh (a) 80000 / 52000
Heating Capacity – BtuH 77000 / 50000
AFUE 96.0
Motor H.P. – Speed – Type 1 – Variable
Motor FLA 11.5
Rated Ext. SP – In. W.C. 0.50
Temperature Rise Range – F 35-65
Shipping Weights 130 lb
SKU 1025967F
 FG7TN MODEL NUMBERS  -060D-V24B1  -080D-V35C1  -100D-V35C1
Input – Btuh (a) 60000 / 39000 80000 / 52000 100000 / 65000
Heating Capacity – BtuH 57000 / 37000 76000 / 49000 95000 / 62000
AFUE 96.0 96.0 96.0
Motor H.P. – Speed – Type 3/4 – Variable 1 – Variable 1 – Variable
Motor FLA 8.8 11.5 11.5
Rated Ext. SP – In. W.C. 0.50 0.50 0.50
Temperature Rise Range – F 30-60 35-65 35-65
Shipping Weights 120 lb 140 lb 145 lb
SKU 1025970F 1025971F 1025972F

Note:
All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

ACCESSORIES

FG7TE/TN KITS

Description SKU
2″ Concentric Vent Kit 904177
3″ Concentric Vent Kit 904176
2″ Concentric Vent Kit (Canadian Approved) 904952
3″ Concentric Vent Kit (Canadian Approved) 904953
“A” Cabinet Downflow Sub Base Kit 902974
“B”, “C”, “D” Cabinet Downflow Sub Base Kit 904911
2″ Side Wall Vent Kit 904617
3″ Side Wall Vent Kit 904347
U.S. LP Conversion Kit (0 to 10,000 ft.) 905028
Canada LP Conversion Kit (0 to 4,500 ft.) 905029
Bottom Return Filter 20 per Box, “B” Cabinet 904916
Bottom Return Filter 20 per Box, “D” Cabinet 904918
Side Return Filter Kit 541036
Neutralizer Kit 902377

BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces - Logo 2GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (06/2019)
477F-0619

BROAN Logo

Documents / Resources

BROAN FG7T (E and N Series) Two Stage, Variable Speed, Condensing Upflow and Downflow Gas Furnaces [pdf] Owner's Manual
FG7T E and N Series Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces, FG7T E and N Series, Two Stage Variable Speed Condensing Upflow and Downflow Gas Furnaces, Variable Speed Condensing Upflow and Downflow Gas Furnaces, Condensing Upflow and Downflow Gas Furnaces, Upflow and Downflow Gas Furnaces, Downflow Gas Furnaces, Gas Furnaces, Furnaces

References

Leave a comment

Your email address will not be published. Required fields are marked *