bridgelux-logo

bridgelux Driver Configuration Software

bridgelux Driver Configuration Software-product

Introduction

1. Software Introduction

Bridgelux Vesta Fusion and Pallas-A drivers can be programmed through “Bridgelux Driver Configuration”. It allows users to configure the output current, minimum dimming ratio, dimming-to-off mode, and dimming voltage (Vesta Fusion also includes controls of dimming curve, dimming mode, fade time, CCT value, etc.)

Operating System Requirements

  • Operating System: Windows 7 Service Pack 1 or higher
  • Software Environment: .NET Framework 4.8 Programming
  • Tool: Bridgelux Driver Configuration V3.0.240515.zip

Note:

  1. NET Framework 4.8 must be installed. Download link: https://dotnet.microsoft.com/download
  2. If your computer cannot automatically install the required driver program, please search for “CH340E Driver” on the internet to download and install the driver.

If your computer cannot automatically install the required tool driver, please click on the link below to download the driver and manual installation:
https://www.wch.cn/downloads/file/65.html?time=2023-03-17%2016:47:34&code=DZOI4uB6P0dEfCxL0bp5AGLyOaggJMAb025ICJEt?time=2023-10-17%2011:00:38&code=Ic43aw5DHnM7D4DwNJcfowsWUTSrDyl8XoYGGj7O

bridgelux-Driver -Configuration -Software-FIG- (1)

Software installation and startupbridgelux-Driver -Configuration -Software-FIG- (2)

“Bridgelux Driver Configuration” folder is free-install software. Just unzip the “Bridgelux Driver Configuration V3.0.240515.zip” to your local drive, and then, double click “Bridgelux Driver Configuration.exe” to start the software.

Programmer Hardware Wring Connection (depends on driver)

bridgelux-Driver -Configuration -Software-FIG- (3)

Software Functionbridgelux-Driver -Configuration -Software-FIG- (4)

Bridgelux Driver Configuration Software UI includes:

  • Title bar: Displays the software name.
  • Operating area: All operation buttons, including user menu, serial port configuration, read parameter, write parameter, load parameter file, export parameter file, loop write parameter, firmware upgrade, about software.
  • Parameter display area: Displays and edits parameter information.
  • Status bar: Displays serial port, firmware version, operation prompt information

User

User loginbridgelux-Driver -Configuration -Software-FIG- (5)

  1. Click User -> login.
  2. Input “password” and then click “login”.
    Note: Default password “adp12346”.

Change passwordbridgelux-Driver -Configuration -Software-FIG- (6)

  1. Click User->Change Password.
  2. Input old password, new password and confirm password then click “Save”.

Exit Loginbridgelux-Driver -Configuration -Software-FIG- (7)Click User-> Exit login, Exits the engineer permission.

Port Configurationbridgelux-Driver -Configuration -Software-FIG- (8)

  1. Click “Port Config”.
  2. Select programmer serial port, baud rate 19200 and then click “OK”.

After plug the Bridgelux programming cable to one of the USB port on your PC. We have to find out which COM port has been assigned to this programming cable

  1. Right click on “Windows” icon (at the bottom left corner)
  2. click on “Device Manager”
  3. From the pop-up window, scroll down to “Ports (COM & LPT)”, you should find the “USB-SERIAL CH340 (COM X). Write down the COM port number as you will need it when you use the Bridgelux Configuration APP in next step.
    • For example, this PC assigned the USB-SERIAL CH340 to COM 3 (your PC may assign different COM port for your case)

bridgelux-Driver -Configuration -Software-FIG- (9)

Read Write Parameters

a Vesta Fusion (Dual Channel Driver)

bridgelux-Driver -Configuration -Software-FIG- (10)

  1. Click Read button. Read all parameters.
  2. Click Write button. Write all parameters to driver.
  3. Click Export File button. Export all parameter to file.
  4. Click Load File button. Load external parameter file.
  5. Click Loop Write button. Write all parameters to driver every 2.5s
Only Read Driver Information
Max Output Power Maximum output power of the driver
Max Load Voltage Maximum load voltage of the driver
Min Load Voltage Minimum load voltage of the driver
Max Setting Current Maximum settable current of the driver
Min Setting Current Minimum settable current of the driver
Output Channel Number of drive output channels
CCT Information
Physical Warmest Configuration physical warmest and coolest color temperature range.

The valid range 1500K-7000K, and the color temperature

should be the same as that of the lamp.

Physical Coolest
Logical Warmest Configuration logical warmest and coolest color temperature range.

The logical color temperature range should be within the

physical color temperature range.

Logical Coolest
Current Information
Warm Current output current of Warm color channel.
Cool Current output current of Cool color channel.
Device Information
Min Dimming Ratio Minimum dimming ratio, 1% 5% 10% is optional.
Dimming To Off Enable or disable dimming to OFF
Dimming Mode Configuration Dimming Mode.

Solo dimming: use “0-10V Dim+” voltage control the intensity of both channels simultaneously.

Warm dimming: use “0-10V Dim+” voltage control both intensity and color temperature simultaneously.

Tunable white: use “0-10V Dim+” voltage control intensity and “0-10V CCT+” voltage control color temperature.

Dimming Curve dimming curve, “logarithmic”, “linear”, “square” is optional
Solo Dimming CCT CCT when the dimming mode is at Solo Dimming
Intensity Fade Time Configuration fade time of intensity changing, the fade time of the driver intensity from A to B.

0ms,250ms,500ms,750ms,1000ms,1250ms,1500ms  is

optional.

CCT Fade Time Configuration fade time of CCT changing, the fade time of the driver CCT from A to B.

0ms, 250ms, 500ms, 750ms, 1000ms, 1250ms, 1500ms is

optional.

Read Write Parameters

b Pallas-A (Single Channel Driver)

bridgelux-Driver -Configuration -Software-FIG- (10)

  1. Click Read button. Read all parameters.
  2. Click Write button. Write all parameters to driver.
  3. Click Export File button. Export all parameter to file.
  4. Click Load File button. Load external parameter file.
  5. Click Loop Write button. Write all parameters to driver every 2.5s
Only Read Driver Information
Max Output Power Maximum output power of the driver
Max Load Voltage Maximum load voltage of the driver
Min Load Voltage Minimum load voltage of the driver
Max Setting Current Maximum settable current of the driver
Min Setting Current Minimum settable current of the driver
Output Channel Number of drive output channels
Current Information
Level 1 – Level 2 Reserved for Bridgelux R&D use only
Level 3 output current setting
Device Information
Min Dimming Ratio Minimum dimming ratio, 1% 5% 10% is optional.
Dimming To Off Enable or disable dimming to OFF
Dimming Voltage Information
Light off Configuration dimming off voltage.
Light on Configuration dimming on voltage.
Dimming Minimum Configuration dimming minimum voltage.
Dimming Maximum Configuration dimming maximum voltage.
AUX Voltage 12 / 24V

Firmware Upgrade

bridgelux-Driver -Configuration -Software-FIG- (12)

  1. Click Firmware Update button, open firmware upgrade UI.
  2. Click Load File button on the firmware upgrade UI, Load Upgrade Bin File.
  3. Select device address “Unicast” or “broadcast” and then click download button.
    Note: Firmware upgrade is not supported, and will be extended in the future.

Aboutbridgelux-Driver -Configuration -Software-FIG- (13)

Click About button, open software information UI. see figure 11

Annex A

Modification record

Version Description Note
V1.0 Bridgelux Driver Configuration Software User

Manual Initial Version

V2.0 Added Single Channel Driver programming info
V3.0 Minor revision
V4.0 Minor revision
V5.0 Revised programming cable physical description

Frequently Asked Questions

  • Q: What are the minimum system requirements for the Bridgelux Driver Configuration Software?
    • A: The software requires Windows 7 Service Pack 1 or higher and .NET Framework 4.8.
  • Q: How can I change the default password for user login?
    • A: To change the password, click on User -> Change Password, enter the old password, new password, and confirm password, then click Save.

Documents / Resources

bridgelux Driver Configuration Software [pdf] User Manual
V5.0, Driver Configuration Software, Software

References

Leave a comment

Your email address will not be published. Required fields are marked *