S21 XP Antminer Server

Specifications:

  • Model: S21 XP
  • Version: 10

Product Information:

The S21 XP server is Bitmain’s newest version in the 21 server
series. It comes with the APW171215 power supply. All S21 XP
servers are tested and configured before shipping to ensure easy
setup.

Components:

The main components and controller front panel of S21 XP servers
are shown in the user manual. The power supply APW171215 is a
crucial component of the server.

Specifications Details:

Model Version Crypto Algorithm/Coins Typical Hashrate, TH/s Power on Wall @25°C, Watt
S21 XP 10 SHA256 | BTC/BCH/BSV 270 3645

Product Usage Instructions:

Setting up the Server:

  1. Download the file IPReporter.zip supported by Microsoft Windows
    from:
    IPReporter.zip
  2. Extract the downloaded file.

Frequently Asked Questions (FAQ):

Q: What is the supported operating temperature range for the
S21 XP Server?

A: The S21 XP Server has an operation temperature range of -20°C
to 45°C.

Q: How can I ensure proper power supply connection for the S21
XP Server?

A: Use one ANTWIRE-20SP power cord connected to PDU for the
power supply APW171215 of the S21 XP Server.

S21 XP Server Installation
Guide
Document Version 1.0
Jul. 2024
© Copyright Bitmain Technologies Holding Company 2007 ­ 2023. All rights reserved. Bitmain Cayman (hereinafter referred to as `Bitmain’) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of order acknowledgment.
Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Bitmain assumes no liability for third-party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which Bitmain products or services are used. Information published by Bitmain regarding third-party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.
Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective holders.

S21 XP Server
All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves the right to make corrections, updates, revisions or changes to the information in this document.
Bitmain Tel: +86-400-890-8855 www.bitmain.com

S21 XP Server
Table of Contents
Menu
1. Overview ………………………………………………………………………………………………………………………………………………….1 1.1 S21 XP Server Components …………………………………………………………………………………………………………………..2 1.2 Specification ……………………………………………………………………………………………………………………………………….3
2. Setting up the Server …………………………………………………………………………………………………………………………………..5 3. Configuring the Server …………………………………………………………………………………………………………………………………8 4. Monitoring Your Server ……………………………………………………………………………………………………………………………….9 5. Administering Your Server ………………………………………………………………………………………………………………………….10
5.1 Checking Your Firmware Version …………………………………………………………………………………………………………..10 5.2 Upgrading Your System ……………………………………………………………………………………………………………………….10 5.3 Modifying Your Password…………………………………………………………………………………………………………………….11 5.4 Restoring Initial Settings………………………………………………………………………………………………………………………11

S21 XP Server 1.Overview
1. Overview
The S21 XP server is Bitmain’s newest version in the 21 server series. Power supply APW171215 is part of S21 XP server. All S21 XP servers are tested and configured prior to shipping to ensure easy set up.

Front View

Back View

Caution: Please refer to the layout above to place your goods in usage in case of any damage. The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible. The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs. DO NOT remove any screws and cables tied on the product. DO NOT PRESS the metal button on the cover. Please note that the actual server shall prevail.

-1-

1.1 S21 XP Server Components
The main components and controller front panel of S21 XP servers are shown in the following figure:

S21 XP Server 1. Overview

APW171215 Power Supply:
Power Supply Socket
Note:
Power supply APW171215 is part of S21 X P server. For detailed parameters, please refer to the specifications below. One ANTWIRE-20SP power cord is needed and should be connected to PDU.
-2-

1.2 Specification
Model: S21 XP Version: 10
Product Glance
Model Version Crypto algorithm/coins Typical Hashrate, TH/s(1-1) Power on wall @25(1-2), Watt(1-1)
Detailed Characteristics
Power supply Power supply AC input voltage(2-1), Volt Power supply AC Input Frequency Range, Hz Power supply AC Input current(2-2), Amp Hardware Configuration Network connection mode Server size (Length*Width*Height, w/o package), mm Server size (Length*Width*Height, with package), mm Net weight, kg
Gross weight, kg Noise(2-3), dBA Environment Requirements Operation temperature, Storage temperature, Operation humidity, RH Operation altitude(2-4), m

S21 XP Server
1. Overview
Value
S21 XP 10
SHA256 | BTC/BCH/BSV 270 3645
Value
220~277V AC 50~60 20
RJ45 Ethernet 10/100M 449*219*293 640*360*450 18.7 21.5 76
-20~45 -20~70 10%~90% 2000

-3-

S21 XP Server

Notes:

1. Overview

(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%. (1-2) Inlet air temperature. (2-1) Caution: Wrong input voltage may probably cause server damaged. (2-2) Single-phase AC input 20A. (2-3) Max condition: Fan is under max RPM(rotation per minute).
(2-4) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1
for every increase of 300m.

-4-

2.Setting up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
1. Go to the following site: https://file12.bitmain.com/shop-product/firmware/IP%20Reporter.zip 2. Download the following file: IPReporter.zip. 3. Extract the file.
The default DHCP network protocol distributes IP addresses automatically.
4. Right-click IPReporter.exe and run it as Administrator. 5. Select one of the following options: Shelf, Step, Position ­ suitable for farm servers to mark the location of the servers. Default ­ suitable for home servers. 6. Click Start.

S21 XP Server 2.Setting up the Server

-5-

S21 XP Server 2.Setting up the Server 7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
The IP address will be displayed in a window on your computer screen.
7. In your web browser, enter the IP address provided. 8. Proceed to login using root for both the username and password. 9. In the Protocol section, you can assign a Static IP address (optional). 10. Enter the IP address, Subnet mask, gateway and DNS Server. 11. Click “Save”. 12. Click https://support.bitmain.com/hc/en-us/articles/360018950053 to learn more about gateway and DNS Serve
-6-

S21 XP Server 2. Setting up the Server
-7-

3.Configuring the Server
Setting up the Pool
To configure the server: 1. Click Settings as below.

S21 XP Server 3. Configuring the Serve

2. Set the options according to the following table:
Note:
Fan speed percentage can be adjusted, but we recommend to keep the default setting. The server will adjust the fan speed automatically if the fan speed percentage has yet been selected.
There are two working modes of S21 XP server: Normal mode and Sleep mode. The server enters the sleep mode under the condition that the control board is powered while hashboards are not powered.

Option Mining address

Description Enter the address of your desired pool.
The S21 XP servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline.

Name

Your worker ID on the selected pool.

Password (optional)

The password for your selected worker.

3. Click Save after the configuration.

-8-

4.Monitoring Your Server
To check the operating status of your server: 1. Click dashboard marked below to check the server status (taking S21 XP 270T as example).

S21 XP Server 4. Monitoring Your Server

2. Monitor your server according to the descriptions in the following table:

Option
Number of chips Frequency Real Hashrate Inlet Temp Outlet Temp Chip state

Description Number of chips detected in the chain. ASIC frequency setting. Real-time Hashrate of each hash board (GH/s). Temperature of the inlet (°C). Temperature of the outlet (°C). One of the following statuses will appear:
The Green Icon – indicates normal The Red Icon- indicates abnormal

-9-

S21 XP Server 5. Administering Your Server
5.Administering Your Server
5.1 Checking Your Firmware Version
To check your firmware version: 1. Enter the backstage of your server, find the firmware version on the bottom. 2. Firmware Version displays the date of the firmware your server uses. In the examples below, the server is using firmware version 20240608.
5.2 Upgrading Your System
Make sure that the S21 XP server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair. To upgrade the server’s firmware: 1. In System, click Firmware Upgrade.
-10-

S21 XP Server 5. Administering Your Server

2. For Keep Settings:

Select “keep settings” to keep your current settings (default).

Unselect “keep settings” to reset the server to default settings.

3. Click the

button and navigate to the upgrade file. Select the upgrade file, then click Update.

4. When the upgrade is completed, restart the server and it will turn to the setting page.

5.3 Modifying Your Password
To change your login password: 1. In System, click the Password tab. 2. Set your new password, then click Save.
5.4 Restoring Initial Settings
To restore your initial settings 1. Turn on the server and let it run for 5 minutes. 2. On the controller front panel, press and hold the Reset button for 10 seconds
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
-11-

S21 XP Server

Environmental Requirements

Please run your server in accordance with the following requirements 1.Basic Environmental Requirements: 1.1 Climatic Conditions:

Description

Requirement

Operating Temperature

-20-45

Operating Humidity

10-90%RH (non-condensing)

Storage Temperature

-20-70

Storage Humidity

5-95%RHnon-condensing

Altitude

2000m

1.2 Site Requirements of the Server Running Room: Please keep the server running room away from industrial pollution sources: For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km. For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km. For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km. If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source. Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling.
1.3 Electromagnetic Environmental Conditions: Please keep your site away from transformers, high-voltage cables, transmission lines and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters. Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.
2. Other Environmental Requirements
The server running room shall be free of explosive, conductive,magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below: 2.1 Requirements of Mechanical Active Substances

Mechanical Active Substance Sand Dust (suspended) Dust (deposited)

Requirement <= 30mg/m3 <= 0.2mg/m3 <=1.5mg/m2h

-12-

2.2 Requirements of Corrosive Gas

Corrosive Gas

Unit

Concentration

H2S

ppb

< 3

SO2

ppb

< 10

Cl2

ppb

< 1

NO2

ppb

< 50

HF

ppb

< 1

NH3

ppb

< 500

O3

ppb

< 2

Note: ppb (part per billion) refers to the unit of concentration1ppb stands for the volume

ratio of part per billion.

S21 XP Server

-13-

Regulations:

S21 XP Server

FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

ROHS:

S21 XP

L1-10

(Pb)

Hg

Cd

(Cr+6)

PBB

PBDE

1. 0.1 wt % 0.01 wt % 2. 3.

-14-

Documents / Resources

BITMAIN S21 XP Antminer Server [pdf] Installation Guide
S21 XP, S21 XP Antminer Server, S21 XP, Antminer Server, Server

References

Leave a comment