S21 Bitmain Antminer
Specifications
Product Glance | Value |
---|---|
Model | S21 |
Sub Version | 200T |
Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
Typical Hashrate, TH/s(1-1) | 200 |
Power on wall @25(1-1), Watt(1-1) | 3500 |
Power efficiency on wall @25(1-1), J/TH(1-1) | 17.5 |
Detailed Characteristics
Value | ||
---|---|---|
Power supply | 220~277 Volts, 50~60 Hz | |
Hardware Configuration | ||
Network connection mode | RJ45 Ethernet 10/100M | |
Server size (Length*Width*Height, w/o package), mm | 400*195*290 | |
Server size (Length*Width*Height, with package), mm | 570*316*430 | |
Net weight, kg | 15.4 | |
Gross weight, kg | 17.2 | |
Noise @30, dBA | 76 | |
Environment Requirements | ||
Operation temperature | 0~45°C | |
Storage temperature | -20~70°C | |
Operation humidity(no condensation), RH | 10%~90% | |
Operation altitude(2-3), m | 2000 (temperature decreases by 1 for every increase of300m) |
Product Usage Instructions
Frequently Asked Questions (FAQ)
Specification
Product Glance | Value |
Model | S21 |
Sub | 200T |
Version | 10 |
Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
Typical Hashrate, TH/s(1-1) | 200 |
Power on wall @25℃(1-2), Watt(1-1) | 3500 |
Power efficiency on wall @25℃(1-2), J/TH(1-1) | 17.5 |
Detailed Characteristics | Value |
Power supply | |
Phase | 1 |
Input voltage(2-1), Volt | 220~277 |
Input frequency range, Hz | 50~60 |
Maximum input current, Amp | 20 |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server size (Length*Width*Height, w/o package), mm | 400*195*290 |
Server size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg | 15.4 |
Gross weight, kg | 17.2 |
Noise(2-2) @30℃, dBA | 76 |
Environment Requirements | |
Operation temperature, ℃ | 0~45 |
Storage temperature, ℃ | -20~70 |
Operation humidity(no condensation), RH | 10%~90% |
Operation altitude(2-3), m | ≤2000 |
Notes:
- The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
- Inlet air temperature.
- Caution: Wrong input voltage may probably cause server damaged.
- The noise is loudest when the fan is under maximum RPM(rotation per minute).
- When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.
Performance Curves
- Hashrate vs. Ambient Temperature
J/T vs. Ambient Temperature
Documents / Resources
![]() |