BEOK-logo

BEOK TCR7 Series RGB Colorful LCD Screen Smart Thermostat

BEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-

Product Overview

This series of thermamost has Floor Heating, Fan Cal, and integrated vision, meeting the requirement under different sonerios

Version System mode Model Application
 

Floor heating

 

 

Heating

EP Built-in & floor sensor, floor limit sensor+ Weekly programming
WP A NC/NOdual-output+ Weekly programming
WPB A NC /NO dual-output+ Weekly programming+ Potential-free output
 

Fan Coil

 

Heating /Cooling/

Ventilation

Ac2 Timer task+ 2-pipe system
Ac2-

485

‘Timer task + 2-pipe system+ 485Modbus (optional)
Ac4 ‘Timer task + 4-pipe system+ 485Modbus (optional)
 

Integrated

Heating/ Cooling/ Ventilation/Floor heating / Floor heating+ Heating AWY Floor heating & fan coil, weekly programming + Potential-free output + Timer task  + 485Modbus (optional)+ Door card (optional)

Display SymbolsBEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-1

 

Temperature Control Mode(Floor Heating/Integrated)

  • Auto Mode
    Weekly-DRC:ted program, up to 6 heating events can be set per day. Heading events, workdays and temperature can be separately customized based on personal routines.
  • Manual Mode
    The thermostat works based on manually-set temperature, disconnecting from auto mode.
  • Temporary Mode
    Thermostat wor1al based on manually-set temperature temporarily and tllen shifts beck to auto mode till next event.

Parameter

  • Supply voltage AC100~240V;50~60Hz
  • Power consumption 1W Max (Wi-Fi 3W Max)
  • Temp. setting range 5~95℃
  • Floor limited range 20~90℃
  • On/off deviation 0.5~10℃, Factory setting ±1℃
  • Ambient temperature -5~50℃
  • Protection level IP20 Anti-Flammable PC

User Operation

  • Power on/off: Press 18 shortly to tum on/off the thermostat.
  • Temp setting: Relate handwheel’ O ‘to change the set temperature by 0.5’C.
  • system article: Presa • ~ • shortly to switch cooling/heating/ventilation. (Fan Coll)
    • press 18 shortly to switch CDOlinglheeting/venliletionlftoor heating/ floor healing+ healing. (lnlagralad)
    • Enter menu: Press ‘Q ‘ enter the menu Interface.
  • Temp control mode: Prass• 83 • shortly ID swild1 manual/auto mode. (Floor heating)
    • Prass• 1′ • shortly ID swild1 manual/auto mode. (lnlllgral8d, floor heating)
  • Child-lock: Press’ M ‘+ • gg “f0r 3 se,;onds to ac:tlvate child-lock.

Auto-mode Setting

When device i& off, press • O • to enlarge menu page, choose “period selling’ ID set pa, monetary, then pr9SS ‘C) • to -and axil.

 

Events

Time Temperature
Default value Modify Default value Modify
 

 

 

 

 

Workdays

Sunrise 06:00  

0

;:a

i

CT

OJ

:J

:C;.;

CT

ffi.

20°C  

0

;:a

i

CT

OJ

:J

:C;.;

CT

ffi.

Morning 08 :00 15 °C
Nooning 11 :30 15 °C
Afternoon 12:30 1 5 °C
Evening 17 :00 2 2 °c
Night 22 :00 15 °C
 

Weekends

Sunrise 06 : 0 0 2   0 ° C
Night 22 :00 15 °C

Advanced Setting (Usually for Professional Technicians)
Choose “advanced 8811ing’ on menu page and put in p868WOl’d 123456 to enter advanced selling page, set parameters then press ·o· to save and exit

Meaning 0 Rotate handwheel Default value
 

 

Sensor Mode

Built-in Sensor Floor Sensor

Built-in Control&Floor Limitation

 

IN

Burt-in Sensor Calibration -5-5°C – 3 °C
Burt-inMaxSettingValue 5- 95 “C 50 °C
Floor Max Setting Value 10- 95 °C 50 °C
Limitation Value 20- 95 °C 35 °C
Output Jitter Control 0- 5 °C 1 °C
Anti-Freeze Protection ON/ OFF OFF
 

 

Linkage Mode

Non inverting Inverting Inverting

Inverting and Anti-Freeze closed

 

 

Noninverting

Linkage lime Delay 0-5Min 0Min
 

Weekday Mode

Monday to Friday/Monday to Saturday

/Mondyato Sunday/

 

2-day

Boot Type Function Off/Function On/Function Saved OFF
Temperature Unit °F /° C “C
 

Child Lock Type

None Lock All

All but power

 

None

Control Mode All/Air/Floor Floor
Cloud Region CN / US / EU CN
Reset All Settings I I

RGB Colorful LCD Screen Smart Thermostat

Sensor failure
Please select work mode of sensors correctly. When It shows EO/E1 error, the thermostat will stay power-off till the error is eliminated.ED: the built-in sensor is short-circuited or disconnected. E1: floor sensor is short-circuited or disconnected.

Timer Task Setting (Fan Coil/Integrated) Press” Q “to enter the menu. Tum the knob” Q “, choose “Auto Mode”, and then choose “Schedule”. Set the parameters by turning the knob, then press” gg • to save and exit to home pageBEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-2

Dimensions (Unit: mm)BEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-3

Mounting Steps
The thermostat adopts a pre-guide and limited snap-fit design. It is easy to mount.

  1. Release the front cover by inserting a head screw-driver into the bottom crack.BEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-4
  2. Insert the wires and then fix these wires with screws. The suggested wire-stripping length is 7-9mm.
  3. Mount backing plate into wall-cassette, put screws and then fix the thermostat. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2-0.4N.m (2.0-4. 1kgf.cm).BEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-5
  4. Re-mount the front cover via snap-fit connection.BEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-6

Connecting Diagram

The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m.

Floor HeatingBEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-7

Fan CoilBEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-8

IntegratedBEOK-TCR7-Series-RGB-Colorful-LCD-Screen-Smart-9

Documents / Resources

BEOK TCR7 Series RGB Colorful LCD Screen Smart Thermostat [pdf] Instruction Manual
tcr7-wifi-ep, tcr7-wifi-wp, tcr7-ep, tcr7-wp, tcr7-wifi-wpb, tcr7-wpb, tcr7-wifi-ac2, tcr7-ac2 tcr7-wifi-ac2-485, tcr7-ac2-485, tcr7-wifi-ac4, tcr7-ac4, TCR7 Series RGB Colorful LCD Screen Smart Thermostat, TCR7 Series, RGB Colorful LCD Screen Smart Thermostat

References

Leave a comment

Your email address will not be published. Required fields are marked *