behringer FP150 Compact Floodlight User Guide

behringer logo

Quick Start Guide

behringer FP150 Compact Floodlight

EUROLIGHT
FLOOD PANEL FP150
Compact Floodlight with 150 RGB LEDs

Important Safety Instructions

behringer FP150 Compact Floodlight - Symbol 1

Electric Warning Icon Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality professional speaker cables with ¼” TS or twist-locking plugs pre-installed.
All other installation or modification should be performed only by qualified personnel.
Electric Warning Icon This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure – voltage that may be sufficient to constitute a risk of shock.
warning 2 This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
warning 2 Caution
To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside. Refer servicing to qualified personnel.
warning 2 Caution
To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus.
warning 2 Caution
These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions.
Repairs have to be performed by qualified service personnel.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Use only attachments/accessories specified by the manufacturer.
  12. behringer FP150 Compact Floodlight - Symbol 2 Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms or when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
    exposed to rain or moisture, does not operate normally, or has been dropped.
  15. The apparatus shall be connected  to a MAINS socket outlet with a protective earthing connection.
  16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
  17. WEE-Disposal-icon.png Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste, according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection center licensed for the recycling of waste electrical and electronic equipment (EEE).
    The mishandling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information about where you can take your waste equipment for recycling, please contact your local city office, or your household waste collection service.
  18. Do not install in a confined space, such as a book case or similar unit.
  19. Do not place naked flame sources, such as lighted candles, on the apparatus.
  20. Please keep the environmental aspects of battery disposal in mind. Batteries must be disposed-of at a battery collection point.
  21. This apparatus may be used in tropical and moderate climates up to 45°C.
  22. warning 2 Warning
    Do not ingest battery.
    Chemical Burn Hazard This product contains a coin/ button cell battery. If the coin/ button cell battery s swallowed or placed inside any part of the body, it can cause severe or fatal nternal burns injuries in just 2 hours or ess and can lead to death.

Keep new and used batteries away from children.
If the battery compartment does not close securely, stop using the product and keep it away from children.
If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
Replacement of a battery with an incorrect type can defeat a safeguard.
Replace only with the same or equivalent type.
Risk of fire or explosion if the battery is replaced by an incorrect type.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, can result in an explosion.
Leaving a battery in an extremely high temperature surrounding environmentcan result in an explosion or the leakagof flammable liquid or gas.
A battery subjected to extremely low apressure may result in an explosion or the leakage of flammable liquid or gas.
Attention should be drawn to the environmental aspects of battery disposal.

Music Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph, or statement contained herein. Technical specifications, appearances and other information are subject to  change without notice.
All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Aston Microphones and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © Music Tribe Global Brands Ltd. 2021 All rights reserved.

LIMITED WARRANTY
For the applicable warranty terms and conditions and additional information regarding Music Tribe’s Limited Warranty, please see complete details online at musictribe.com/warranty.

warning 2 Additional Safety Instructions

  1. When opening the package, take all the accessories out, and place the device on a table for inspection. First check whether the accessories are complete, then inspect the device carefully for any damage. If there is any damage, please contact your dealer as soon as possible.
  2. AC Power: Check that the local power supply is in accordance with the requirements of the rated voltage of the device.
  3. The device is only suitable for an indoor working environment. It should be kept in a dry environment, and away from any moisture, overheating or dust. Do not allow the device to come into contact with water, moisture, or other liquids, in order to prevent or reduce the risk of electric shock or fire.
  4. Please do not install the device directly onto, or close to, combustible surfaces or materials.
  5. Personnel who install, operate and maintain the device must be professionally licensed and authorized to do so.
  6. If the device appears to be malfunctioning, stop using the device immediately. Do not try to repair the device, but contact the nearest authorized technical assistance center. If parts are damaged, always use identical authorized replacement parts.
  7. Do not touch any electrical wiring in the process of operation, to prevent the risk of electric shock.
  8. Make sure the device is used in a working environment temperature, that does not exceed 40ºC or below – 20ºC.
  9. In normal operation, the highest temperature of the device housing may reach 80ºC, please do not touch.
  10. The device should only be used in a grounded power system, and the ground wire must connect with the ground wire of the power supply system. The ground/earth sign of the device should be connected to the installing fixtures.
  11. Do not use the device if there is damage to the power cord insulation, and also do not run the power cord so it overlaps other wires in your system.
  12. When not in use or when cleaning the device, please disconnect the power cord to the device.
  13. There are no user-serviceable components inside the device. Before operation of the device, please make sure the device is secure and all assembly screws and fittings are fitted. If the device outer case is open or loose, the device must not be used.
  14. Regular checks must be conducted by qualified personnel to ensure that the system remains in a secure and stable condition.
  15. Make sure that, where the product is suspended, the area underneath the product is free of human traffic. Do not suspend the product in areas which can be entered or used by members of the public.

Secondary Safeties
All lighting units installed in theatres, studios or other places of work and entertainment shall, in addition to the principle load bearing means of suspension, be provided with an independent, properly rated, and securely attached secondary safety. The additional safety device must be mounted in a way that the lighting unit is caught by the safety device without any drop and swing in the event that the primary suspension fails.

Product Care and Cleaning
Please pay attention to the following points when using and inspecting this product:

  • All screws and components of the installed product must be tightly connected and not rusty or damaged
  • The outer casing, lens, fixing parts and installation location (such as ceiling, hanger, truss, etc.) cannot be deformed
  • The power cord must not be damaged

The installation and use of the product must be carried out by trained professional technicians and must be protected against potential safety hazards.

warning 2 WARNING: Please unplug the power cord before doing product maintenance!
Before disconnecting the device or starting maintenance work, make sure that the device is disconnected. It is very important to keep the device clean and clean. If it is kept clean, this not only keeps the output at the maximum brightness, but it also prolongs its service life. Use high-quality professional glass cleaner and clean with a soft rag. Under no circumstances should alcohol or chemical solvents be used. The interior of the device and the fan should be cleaned at least quarterly using a vacuum cleaner.

Features

behringer FP150 Compact Floodlight - Features

Front Panel
(1) Flood Panel
(2) Mounting Bracket Tighteners
(3) Mounting Bracket
Rear Panel
(4) AC power input connector with fuseholder
(5) AC power output connector
(6) DMX input
(7) DMX output
(8) Display and navigation buttons
(9) Secondary safety attachment

Features

  • Professional 15-Watt flat and compact LED floodlight
  • Ideal for wall wash, lighting stages, events and parties
  • Lamp houses 150 red, green blue ultra-bright 10 mm LEDs
  • System can be operated via DMX console, master/slave, integrated display and optional remote control
  • Standalone operation with 16 programmed automated shows and 17 color macros
  • Onboard sound-to-light mic module for creating light show automatically from music beat
  • Power link allows daisy chaining between units, saving time and the need for additional extension cords
  • Tight 30 degree beam angle
  • Double bracket enables use in ground or truss-mount application

Display

behringer FP150 Compact Floodlight - Display

Item  No.  Silkscreen  Function
Button: 1 MENU Activates main menu and toggles between menu items. Closes an open submenu without saving
2 DOWN Decreases the displayed value by one/ Navigate function
3 UP Increases the displayed value by one/ Navigate function
4 ENTER Enter selected function/  Confirm and save
LED: 5 DMX Flashes when in DMX mode
6 MASTER Flashes when in MASTER Mode
7 SLAVE Flashes when in SLAVE Mode
8 SOUND Flashes when in  Sound Active Mode

Display Functions
Press the MENU button to access menu options, keep pressing MENU to toggle menu items. Press the ENTER button to access desired functions and the display will flash, then use the UP/DOWN buttons to navigate and select the desire setting. Press ENTER to save and confirm, or press MENU to go back without saving.
The main functions are as follows:

Menu Options and Settings  Description
Addr A001-512 UP/Down to select address from 1 to 512
ChAn 5Ch/8Ch DMX Channel selection 5/ 8 Channel mode
MASL MASt Activate MASTER (HOST) mode option
SLAv Activate SLAVE mode: when connected to DMX input, slave unit replicates the master (HOST) unit
CoLo Co- Activate Color mode, select one of the 16 preset colors below
Co01 Preset color 1 Red
Co02 Preset color 2 Green
Co03 Preset color 3 Blue
Co04 Preset color 4 White
Co05 Preset color 5 Lime
Co06 Preset color 6 Royal purple
Co07 Preset color 7 Orange
Co08 Preset color 8 Aqua green
Co09 Preset color 9 Purple
Co10 Preset color 10 Gold
Co11 Preset color 11 Cyan
Co12 Preset color 12 Lavender
Co13 Preset color 13 Yellow
Co14 Preset color 14 Sky Blue
Co15 Preset color 15 Magenta
Co16 Preset color 16 Warm White
Co17 Preset color 17 Cool White
Stro FS00-99 Select strobe frequency from FS00 = off, FS99=Max strobe speed
Auto SPEd SP01-99 Activate Auto mode.Select SP01 Min speed, SP99 Max speed
Stro FS00-99 Auto mode select strobe frequency from FS00 = off, FS99=Max strobe speed
ProG Pr- Pr01 – 16 Activate SHOW mode. Select PR1-16 to select among 16 preset shows. Pr01-05 color fade, Pr06-10 color jump, Pr11-16 Fade in/fade out
Sped SP01-99 Show mode select SP01 Min speed, SP99 Max speed
Manu dIM d000-100 Manual mode select dimmer brightness from 0 = off, 100=max
r r000-r255 Manual mode select Red LED brightness from 0 = off, 255=max
G G000-G255 Manual mode select Green LED brightness from 0 = off, 255=max
b b000-b255 Manual mode select Blue LED brightness from 0 = off, 255=max
Stro FS00-99 Manual mode select strobe frequency from FS00 = off, FS99=Max strobe speed
SoUn on Turn SOUND CONTROL ON. The AUTO and Show mode will follow the rhythm of the music
oFF Turn SOUND CONTROL mode OFF
Sens S001-100 Select sound sensitivity of SOUND mode from low to 100 high
bLnD no when DMX signal is interrupted, it will go back to last selected mode
YES when DMX signal is interrupted, it will black out
Led on The led display is always ON
oFF The led display will turn off after 25-30 seconds. Touch any key to turn it back ON
Disp dISP The led display in normal direction
dSIP The led display inverted 180 degree
tESt tESt Press ENTER to start test mode, light will perform routine test
FhrS Press enter to show fixture run time
vEr Press enter to show software version

Controlling the Device

AC Power Connections

behringer FP150 Compact Floodlight - AC Power Connections

The Lighting device uses an IEC AC power input receptacle with in-line fuseholder.
WARNING:
Make sure that all AC Power is turned off before making power connections.
Make sure the total current draw from all units does not exceed the capacity of the AC Mains supply.
Do not use with Dimmers
The AC mains power supply must be grounded, and the mains connection to the Lighting unit must use a 3-pin power cord.
The power must be disconnected before checking or replacing the in-line fuse.

Controlling the Device
The device can be controlled in the following ways:

  1. Stand Alone
  2. Master/slave
  3. DMX control
  4. IR Remote Control

Stand Alone
The device can be used on its own, without a DMX controller

  1. Use the COLO menu to select from 17 preset colors
  2. Use the AUTO menu to select Auto mode
  3. Use the PROG menu to select from 16 automatic preprogrammed shows
  4. Use the SOUN menu to select sound activation of the internal shows
  5. Use the MANU menu to select customized color and strobe frequency

Master/Slave Control

  1. Connect the device(s) with DMX cable(s) as shown in the DMX Control section.
    Note: In order to prevent interference, connect less than or equal to 32 units at one time.
  2. Set the master unit:
    2.1. Press MENU of the first device
    2.2. Press ENTER
    2.3. Use UP and DOWN to select MAST
    2.4. Press ENTER (now the first unit is the master)
    2.5. Press MENU and select any COLO, AUTO, PROG, SOUN, MANU mode
    2.6. Press ENTER
    2. 7. After 5-10 seconds of inactivity, the show mode will be activated
  3. Set the slave unit(s):
    3.1. Press MENU and select MASL (use the same operation on all slave units)
    3.2. Press ENTER
    3.3. Then use UP and DOWN to select SLAV
    3.4. Press ENTER to confirm

behringer FP150 Compact Floodlight - Slave Control

DMX Control
To use a DMX controller to control the devices, the ADDRESS menu is used to set the DMX address code of each device (the address code range is between 1-512) so that the devices can receive the DMX signal. The DMX operation can be 5 or 8 Channels.

  1. Connect the output port of your DMX Controller to the DMX input port of the first device, and connect the DMX output port to the DMX input port of the second device, and so on, until all units are connected
  2. In the ADDR menu for each device, enter the address code that matches your DMX controller
  3. In the CHAN menu, select from 5 or 8 channels, depending on your controller or preference
  4. The DMX Controller can now control the devices

behringer FP150 Compact Floodlight - DMX Control

DMX connection requires terminal (loop connection)
During the installation process, if the signal line is laid a long distance, or in a noisy environment, such as a dance hall, it is recommended to use a DMX terminal (loop connection). This can reduce any interference to the digital control signal by electrical noise.
The DMX terminator consists of a simple XLR connector with pin 2 and 3 connected to a 120 Ω resistor. Please insert the terminator into the XLR output port of the last device, please refer to the figure below.

behringer FP150 Compact Floodlight - DMX connection requires

IR Remote Control (Optional)
When using the remote control, the space between the device and the remote control should be kept free of obstacles.
The remote control has a range of 10 meters.

behringer FP150 Compact Floodlight - IR Remote Control

Button Function
ON/OFF Press to turn unit on, press again to turn off
AUTO Activate AUTO mode
PRG Active Show mode. Use + / – to select the preset program from PR01 to 16
SOUND Turn Sound Control On/OFF. When ON, press + / – to adjust the sensitivity from s001 to s100*
SPEED Activates speed setting when AUTO and PRG mode is ON.
Use + / – to adjust the speed from SP01 to SP99 *
STROBE Activates strobe. Use + / – to adjust the speed from FS00 to FS99 *
+ Press to increase the current value. Press – to decrease.
DIMMING Dimmer can be used in AUTO mode, PRG mode, SOUND mode, and static color.
– Press to decrease the current value to a minimum value of 0.
Press + to increase.
W, R, G, B Select color for dimmer mode (White, Red, Green, Blue).
Note: W is linked to preset macro; A and UV are not available
9-Jan Select preset color
Notes *Each press of +/- increases/decreases by 1, but if held down, the values change faster.

Remote Control Battery

  1. The battery positive (+) should face as shown below.
  2. The arrow indicates the plastic lock.

behringer FP150 Compact Floodlight - Remote Control Battery

warning 2 Warning: Do not ingest battery. Chemical Burn Hazard
This product contains a coin/ button cell battery. If the coin/ button cell battery is swallowed or placed inside any part of the body, it can cause severe or fatal internal burns injuries in just 2 hours or less and can lead to death.
Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.

DMX Channel (8CH)

Channel Description Numerical Value Function
1 Master dimmer 0 — 255 Master thmmer from 0-100%
2 Strobe 0 — 7 No function
8 — 15 Blackout
16 — 115 Strobe
116 — 123 No function
124 — 173 Pulse, Tum on and fade off, fade speed increase by value
174 — 181 No function
182 — 231 Pulse, Fade ON and black out, fade speed increase by value
232 — 239 No function
240 — 247 Thunder effect
248 — 255 No function
3 Red 0 — 255 Red Mmmer from 0-10096
4 Green 0 — 255 Green Mmmer from 0-100%
5 Blue 0 — 255 Blue dimmer from 0-100%
6 Color Macro 0 — 17 No function
18 — 31 Preset color Red
32 — 45 Preset color Orange
46 — 59 Preset color Yellow
60 — 73 Preset color Lime
74 — 87 Preset color Green
88 — 101 Preset color Aqua green
102 — 115 Preset color Cyan
116 — 129 Preset color Sky Blue
130 — 143 Preset color Blue
144 — 157 Preset color Royal purple
158 — 171 Preset color Purple
172 — 185 Preset color Lavender
186 — 199 Preset color Magenta
200 — 213 Preset color Gold
214 — 227 Preset color Warm White
228 — 241 Preset color White
242 — 255 Preset color Cool White
7 Preset Show 0 — 17 No function
18 — 31 Preset show 1 Color Fade
32 — 45 Preset show 2 Color Fade
46 — 59 Preset show 3 Color Fade
60 — 73 Preset show 4 Color Fade
74 — 87 Preset show 5 Color Fade
88 — 101 Preset show 6 Color lump
102 — 115 Preset show 7 Color lump
116 — 129 Preset show Rotor lump
130 — 143 Preset show 9 Color lump
144 — 157 Preset show 10 Color lump
158 — 171 Preset show 11 Color FadeIN/fade Out
172 — 185 Preset show 12 Color Fade IN/Fade Out
186 — 199 Preset show 13 Color Fade IN/Fade Out
200 — 213 Preset show 14 Color Fade IN/Fade Out
214 — 227 Preset show 15 Color Fade IN/Fade Out
228 — 241 Preset show 16 Color Fade IN/Fade Out
242 — 255 AUTO mode
8 Show speed and sound control 0 — 127 Preset show speed slow to fast, Max 127
128 — 255 Sound control on, increase microphone sensitivity, Max 255

Specifications

Category Parameter
Light source 49 x 10mm red LED
51 x 10mm green LED
51 x 10mm blue LED
Beam angle 30°
Channels 5CH, 8CH
Control mode DMX
Master-slave Integrated display Sound active
IR control (optional)
Display 7 segment LED
Voltage AC100-240 V, 50/60 Hz
Power consumption 16W
Power cord daisy chain Maximum 17 units @110 V, 26 units @220 V
Dimensions (H x W x D) 259 x 261 x 67 mm
Net weight 1.9 kg
Supplied items Flood Panel FP150
ManualStanding bracket IK power cable
Optional items Safety cable
DMX signal cable IRC1 remote control

Other important information

Important information 

  1. Register online.
    Please register your new Music Tribe equipment right after you purchase it by visiting musictribe.com. Registering your purchase using our simple online form helps us to process your repair claims more quickly and efficiently.
    Also, read the terms and conditions of our warranty, if applicable.
  2. Malfunction. Should your
    Music Tribe Authorized Reseller not be located in your vicinity, you may contact the Music Tribe Authorized Fulfiller for your country listed under “Support” at musictribe.com. Should your country not be listed, please check if your problem can be dealt with by our “Online Support” which may also be found under “Support” at musictribe.com. Alternatively, please submit an online warranty claim at musictribe.com BEFORE returning the product.
  3. Power Connections.
    Before plugging the unit into a power socket, please make sure you are using the correct mains voltage for your particular model. Faulty fuses must be replaced with fuses of the same type and rating without exception.

CE SYMBOL Hereby, Music Tribe declares that this product is in compliance with Directive 2014/35/EU,Directive 2014/30/EU, Directive 2011/65/EU and Amendment 2015/863/EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC and Directive 1907/2006/EC.
Full text of EU DoC is available at https://community.musictribe.com/
EU Representative: Music Tribe Brands DK A/S
Address: Ib Spang Olsens Gade 17, DK – 8200 Aarhus N, Denmark

We Hear You
behringer logo

Documents / Resources

PDF thumbnailFP150 Compact Floodlight
User Guide · FP150, FP150 Compact Floodlight, Compact Floodlight, Floodlight

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.