Technical amendments reserved
Performance floodlight
85 157
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology
Colour graphite or silver
Clear safety glass
Silicone gasket
Reflector surface made of pure aluminium BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+95°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
– Conformity mark
Wind catching area: 0.053 m²
This product contains light sources of energy efficiency class(es) E, F
Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 6 mm) and hexagon nut (wrench size 30 mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 12 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm, see sketch B).
The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow (1), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.
Lamp | |
Module connected wattage | 96.4 W |
Luminaire connected wattage | 108 W |
Rated temperature | ta = 25 °C |
Service life criteria | 50 000 h / L70 |
85 157 K3 | |
Module designation | 4x LED-0800/930 |
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 13400 lm |
Luminaire luminous flux | 8859 lm |
Luminaire luminous efficiency | 82 lm / W |
85 157 K4 | |
Module designation | 4x LED-0800/940 |
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 13600 lm |
Luminaire luminous flux | 8991 lm |
Luminaire luminous efficiency | 83,2 lm / W |
Light technique
Symmetrical wide beam light distribution Half beam angle 26°
For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
Replace LED module.
Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 292 | Optical filter flat beam |
71 334 | Shield |
71 339 | Cylindrical shield |
70 214 | Pole cap for pole top ø 48 mm |
70 248 | Pole cap for pole top ø 60 mm |
70 249 | Pole cap for pole top ø 76 mm |
70 229 | Pole cap for pole top ø 82 mm |
70 245 | Mounting box · rectangular |
70 280 | Tube clamp |
70 379 | Cross beam |
70 889 | Lashing strap |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass Trim ring silver with glass LED power supply unit LED module 4000 K LED module 3000 K Reflector Gasket housing Gasket trim ring |
25 000 301 25 000 302 DEV-0363/700 LED-0800/940 LED-1374/830 75 004 951 83 001 780 83 002 225 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
Documents / Resources
![]() |
BEGA 85 157 Performance Floodlight [pdf] Instruction Manual 85 157, 85 157 Performance Floodlight, Performance Floodlight, Floodlight |