BEA LZR-FLATSCAN 3D SW Door Control Wiring Matrix
Specifications
- Model: LZR-FLATSCAN SW / LZR-FLATSCAN 3D SW
- Manufacturer: BEA, Inc.
- Control Harness: 20.5433
- Power Input: 24V DC
Product Usage Instructions
Installation Requirements
Before starting the installation process, ensure that:
- Installation and service technicians are certified appropriately.
- Risk assessments are conducted after each installation.
- Compliance with local, national, and international regulations is verified.
- All necessary signage and warning labels are in place.
Wiring Instructions
Refer to the provided wiring matrix for connecting the control harness to compatible door/gate systems.
Power Connection
Connect the power input to a 24V DC power source following the specified wiring connections.
Additional Information
For detailed instructions on specific door/gate systems, refer to the BEA product User’s Guide and OEM manual.
FAQ
- Q: What certifications are recommended for installation technicians?
A: BEA, Inc. recommends AAADM certification for pedestrian doors, IDA certification for doors/gates, and factory training for the specific door/gate system. - Q: What should be verified before starting the installation process?
A: Verify that all appropriate industry signage, warning labels, and placards are in place, and that technicians are certified and compliant with regulations.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place.
Control Harness: 20.5433
Control Harness: 20.5433 | ![]() |
![]() |
![]() |
![]() |
![]() |
W | ![]() |
![]() |
![]() |
![]() |
|
POWER 1 | O1: N.O. | O1: N.C. | O1: COM | O2: REACTIVATION 2 | O2: ACT (COM) | O3: VPB 3 | MONITORING 4 | ||||
Besam ETIK 5 | 30.5558 | 15/17 | 16/18 | Logic Module | 12 | 13 | Not supported. | ||||
Besam MP/CUP | 30.5558 | 5 | 4 | Logic Module | 4 | 3 | Not supported. | ||||
Besam PowerSwing/EXB | 30.5558 | TB4-29 | TB4-26 | Logic Module | TB3-20 | TB3-21 | Not supported. | ||||
Besam SM | 30.5558 | TB1-7 | 3 | Logic Module | 3 | 1 | Not supported. | ||||
Assa Abloy SW 100/200, DITEC HA9 6 | 24V+ | GND | EXU-SA 3 | EXU-SA1 | EXU-SA 1 and 2 (N.C.) | CU-ESD 1 | CU-ESD 2 | Refer to BEA product User’s Guide and OEM manual. | |||
CONDOR | 30.5558 | DMS O | COMMON N | V and W | COM 16 | ACTIVATE 17 | Not supported. | ||||
DCU DC700 Access Auto. ES500 Quad Systems ES500 |
30.5558 | CN6 GREEN | CN6 BLACK | AUX CN7 (AF = 2) | CN2 #3 | CN2 #2 | Not supported. | ||||
Detex BS1000S/UDC100 | 30.5558 | 5 | 1 | J2-3 and 1 | 1 | 2 | Not supported. | ||||
Dor-O-Matic | 30.5558 | PURPLE | GRAY | Logic Module | GRAY | YELLOW | Not supported. | ||||
Dorma 400/700 | 30.5558 | SWING | GND | APPR and GND | GND | TRIGGER | Not supported. | ||||
Dorma ED 100/250 7 | 1 | 3 | 15 | 3 | 11 (N.C.) | 3 | 42 | Refer to BEA product User’s Guide and OEM manual. | |||
Gyrotech/Nabco Magnum | 30.5558 | 3 VIOLET | 5 RED | Logic Module | 5 RED | 6 BLACK | Not supported. | ||||
Gyrotech/Nabco Opus | 30.5558 | 5 | 2 | 2 and 4 | 2 | 3 | 1 and 7 | ||||
Gyrotech/Nabco U19 | 30.5558 | WHITE 6B | RED 7 | Logic Module | RED 7 | 61/62 | Not supported. | ||||
Gyrotech 300/400 8 | 30.5558 | WHITE | RED | Logic Module | RED | BLACK | Not supported. | ||||
Horton 4160-3 9 | 30.5558 | DAUGHTER BOARD | DAUGHTER BOARD | Logic Module | WHITE | BLACK | Not supported. | ||||
Horton 4190 10 | 30.5558 | 10 | 3 | 11 and 2 | 3 | 2 | Not supported. | ||||
Horton 5190 | +24 VDC | 0 V | CN16 ORANGE (10) | CN16 YELLOW (9) | CN16 GREEN (8) | CN16 BROWN (7) | CN20: 2 = interior, 3 = exterior CN7 COM | CN16 PURPLE (13), BLUE (14) | |||
Hunter HA, DITEC HA8 | 30.5558 | SAFE 2 | RTN | ACT 2 and return | RTN | ACT | Not supported. | ||||
Keane-Monroe K | 30.5558 | YELLOW | WHITE | Logic Module | WHITE | GREEN | Not supported. | ||||
LCN Digital / Senior Swing | 30.5558 | P2 GREEN | P2 WHITE | P3 white and green | P6 GRAY | P6 YELLOW | Not supported. | ||||
Record 6000/8000 11 | 4 | 6 | 10 | 11 | 11 and 12 (N.C.) | 1 | 2 | Refer to BEA product User’s Guide and OEM manual. | |||
Stanley “L” 12 | 30.5558 | BLUE | YELLOW | Logic Module | YELLOW | ORANGE | Not supported. | ||||
Stanley MP | 30.5558 | 7 | 8 | Logic Module | 8 | 2 | Not supported. | ||||
Stanley MC 521 13 | 30.5558 | TB3-4 | TB3-3 | TB5 3 and 4 | TB4-3 | TB4-4 | Refer to BEA product User’s Guide and OEM manual. | ||||
Stanley MC 521 Pro and IQ 13 | TB4-5 | TB4-6 | TB3-4 | TB3-3 | TB5 3 and 4 | TB4-3 | TB4-4 | Refer to BEA product User’s Guide and OEM manual. | |||
Tucker | 30.5558 | J4-14 | J4-8 jumped to 12 & 13 | N.C. contact between J4 13 and COM | J4-8 jumped to 12 & 13 | J4-10 | Not supported. | ||||
Tormax 1301Motion | 30.5558 | SAFETY A #2 | SAFETY A #1 | A6 | A5 | INPUT C #2 | Refer to BEA product User’s Guide and OEM manual. | ||||
Tormax TDA | 30.5558 | 7 | 8 | C4 and C8 | 8 | 2 | Not supported. | ||||
Tormax TTX II | 30.5558 | 14 | 17 and 18 | 4 | 5 | Not supported. |
Note 1 | If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product. | ||||||||||||||||||
Note 2 | LE21 function or BR3-X programmed to function 22 | ||||||||||||||||||
Note 3 | FS3D only. | ||||||||||||||||||
Note 4 | Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:
Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance. |
||||||||||||||||||
Note 5 (BESAM ETIK) |
Jump 17+18, if not used. | ||||||||||||||||||
Note 6 (BESAM SW 100/200) |
Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board. Blanking Potentiometer must be set fully counterclockwise. Auxiliary switch may be used for home switch. |
||||||||||||||||||
Note 7 (DORMA ED 100/250) |
Jump 11+3 on ontrol. Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function “Sr” is set to 1. | ||||||||||||||||||
Note 8 (GYROTECH 300/400) |
Set control to “swing-safe.” | ||||||||||||||||||
Note 9 (HORTON 4160-3) |
Must have daughter board. | ||||||||||||||||||
Note 10 (HORTON 4190) |
PNP harness p/n: 20.5322 | ||||||||||||||||||
Note 11 (RECORD 6000/8000) |
Jump 11+12 and 14+15. | ||||||||||||||||||
Note 12 (STANLEY “L”) |
The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used. | ||||||||||||||||||
Note 13 (STANLEY MC521 / MC521 PRO) |
Jump TB2 2+3 (if not using factory On/Off/Hold Switch). |
Tech Support: 1-800-407-4545
Customer Service: 1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com
www.BEAsensors.com
Documents / Resources
![]() |
BEA LZR-FLATSCAN 3D SW Door Control Wiring Matrix [pdf] Owner's Manual LZR-FLATSCAN 3D SW Door Control Wiring Matrix, LZR-FLATSCAN 3D SW, Door Control Wiring Matrix, Control Wiring Matrix, Wiring Matrix, Matrix |