BEA LZR-MICROSCAN T Door Control Wiring Matrix
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
Pwr Harness (20.5095) | Door Control Harness (20.5222) | System Harness (20.5304) | ||||||||||
R | Bk | G | Y | W | G | Y | W | O | O | Gy | P | |
R | R | R | Gy | Bl | ||||||||
POWER 1 | ACT (N.O.) | ACT (N.C.) | ACT (COM) | STALL (N.O.) | STALL (N.C.) | STALL (COM) | HOME see note 2 |
HOME see note 2 |
PUSH PLATE | MONITORING 3 | ||
Besam ETIK 4 | 30.5558 | 13 | 12 | 15/17 | 16/18 | DPS | Connect any dry-contact, knowing act device to the 2 gray wires. Be certain to turn on Knowing Act at the hub. |
Not supported. | ||||
Besam MP/CUP | 30.5558 | 3 | 4 | 5 | 4 | DPS | Not supported. | |||||
Besam Power Swing/EXB | 30.5558 | TB3-21 | TB3-20 | TB4-29 | TB4-26 | DPS | Not supported. | |||||
Besam SM 900/CU2 | 30.5558 | 1 | 3 | TB1-7 | 3 | DPS | Not supported. | |||||
Assa Abloy SW 100/200, Ditec HA9 5 | 24V+ | GND | CU-ESD 2 | CU-ESD 1 | EXU-SA 3 | EXU-SA1 | EXU-SA 7 | EXU-SA 8 | Refer to BEA product User’s Guide and OEM manual. | |||
CONDOR | 30.5558 | ACTIVATE 17 | COM 16 | DMS O | COMMON N | DPS | Not supported. | |||||
DCU DC700 Access Auto. ES500 Quad Systems ES500 |
30.5558 | CN2 #2 | CN2 #3 | CN6 GREEN | CN6 BLACK | DPS | Not supported. | |||||
Detex BS1000S/UDC100 | 30.5558 | 2 | 1 | 5 | 1 | DPS | Not supported. | |||||
Dor-O-Matic | 30.5558 | YELLOW | GRAY | PURPLE | GRAY | DPS | Not supported. | |||||
Dorma 400/700 | 30.5558 | TRIGGER | GND | SWING | GND | DPS | Not supported. | |||||
Dorma ED 100/250 6 | 1 | 3 | 42 | 3 | 15 | 3 | 97 | 98 | Refer to BEA product User’s Guide and OEM manual. | |||
Gyrotech/Nabco Magnum | 30.5558 | 6 BLACK | 5 RED | 3 VIOLET | 5 RED | DPS | Not supported. | |||||
Gyrotech/Nabco Opus | 30.5558 | 3 | 2 | 5 | 2 | DPS | Refer to BEA product User’s Guide and OEM manual. | |||||
Gyrotech/Nabco U19 | 30.5558 | 61/62 | RED 7 | WHITE 6B | RED 7 | DPS | Not supported. | |||||
Gyrotech 300/400 7 | 30.5558 | BLACK | RED | WHITE | RED | DPS | Not supported. | |||||
Horton 4160-3 8 | 30.5558 | BLACK | WHITE | DAUGHTER BOARD | DAUGHTER BOARD | DPS | Not supported. | |||||
Horton 4190 | 30.5558 | 2 | 3 | 10 | 3 | DPS | Not supported. | |||||
Horton 5190 9 | 30.5558 | CN20
2 = interior 3 = exterior |
CN7 COM | CN16 ORANGE (10) | CN16 YELLOW (9) | DPS | Not supported. | |||||
Hunter HA, Ditec HA8 | 30.5558 | ACT | RTN | SAFE 2 | RTN | DPS | Not supported. | |||||
Keane-Monroe K | 30.5558 | GREEN | WHITE | YELLOW | WHITE | DPS | Not supported. | |||||
LCN Digital / Senior Swing | 30.5558 | P6 YELLOW | P6 GRAY | P2 GREEN | P2 WHITE | DPS | Not supported. | |||||
Record 6000/8000 10 | 4 | 6 | 2 | 1 | 10 | 11 | DPS | Refer to BEA product User’s Guide and OEM manual. | ||||
Stanley “L” 11 | 30.5558 | ORANGE | YELLOW | BLUE | YELLOW | DPS | Not supported. | |||||
Stanley MP | 30.5558 | 2 | 8 | 7 | 8 | DPS | Not supported. | |||||
Stanley MC 521 12 | 30.5558 | TB4-4 | TB4-3 | TB3-4 | TB3-3 | see note 3 | Refer to BEA product User’s Guide and OEM manual. | |||||
Stanley MC 521 Pro and IQ 12 | TB4-5 | TB4-6 | TB4-4 | TB4-3 | TB3-4 | TB3-3 | see note 3 | Refer to BEA product User’s Guide and OEM manual. | ||||
Tucker | 30.5558 | J4-10 | J4-8 jumped to 12 & 13 | J4-14 | J4-8 jumped to 12 & 13 | J5 – 4 and 5 | Not supported. | |||||
Tormax 130iMotion | 30.5558 | INPUT C #2 | INPUT C #1 | SAFETY A #2 | SAFETY A #1 | DPS | Refer to BEA product User’s Guide and OEM manual. | |||||
Tormax TDA | 30.5558 | 2 | 8 | 7 | 8 | DPS | Not supported. | |||||
Tormax TTX II | 30.5558 | 5 | 4 | 14 | DPS | Not supported. |
Note 1 | If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product. | ||||||||||||||||||
Note 2 | Auxiliary Switch: If installing onto a pair or double-egress, ensure to series both home switches. Switches must close when door is closed. | ||||||||||||||||||
Note 3 | Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:
Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance. |
||||||||||||||||||
Note 4 (BESAM ETIK) |
Jump 17+18, if not used. | ||||||||||||||||||
Note 5 (BESAM SW 100/200, Ditec HA9) |
Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board. Blanking Potentiometer must be set fully counterclockwise. Auxiliary switch may be used for home switch. |
||||||||||||||||||
Note 6 (DORMA ED 100/250) |
Jump 11+3 on control. Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function “Sr” is set to 1. |
||||||||||||||||||
Note 7 (GYROTECH 300/400) |
Set control to “swing-safe.” | ||||||||||||||||||
Note 8 (HORTON 4160-3) |
Must have daughter board. | ||||||||||||||||||
Note 9
(HORTON 5190) |
If using the MICROSCAN On/Off/Hold switch, BEA recommends using CN20 terminal 2.
The CN1 harness will sync two operators so you do not have to use both door control “a” and “b” harnesses. |
||||||||||||||||||
Note 10 (RECORD 6000/8000) |
Jump 11+12 and 14+15. | ||||||||||||||||||
Note 11 (STANLEY “L”) |
The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used. | ||||||||||||||||||
Note 12 (STANLEY MC521 / MC521 PRO and IQ) |
Jump TB2 2+3 (if not using factory On/Off/Hold Switch). |