QUICK GUIDE
IXIO-DT1
MOTION AND PRESENCE SENSOR FOR
AUTOMATIC SLIDING DOORS
Software version 6.3 / Configuration 42.4463.03
(refer to Admin menu for product software vesion)
DT1 Motion And Presence Sensor For Automatic Sliding Doors
https://www.qrfy.com/pxr1pxFaG0
READ BEFORE BEGINNING INSTALLATION & SETUP
![]() |
![]() |
![]() |
![]() |
The sensor should be mounted securely to avoid extreme vibrations. |
Do not cover the sensor. | Avoid moving objects and light sources in the detection field. | Avoid highly reflective objects in the infrared field. |
![]() |
![]() |
![]() |
![]() |
The door control unit and the header cover profile must be correctly grounded. | Only trained and qualified personnel are recommended for installation and setup of the sensor. | Following installation, always test for proper operation (according to ANSI 156.10) before leaving the premises. | The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel. |
This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
MOUNTING & WIRING
Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application.Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the
Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness and/or IXIO sensor.
RADAR OPENING IMPULSE FIELD
INFRARED SAFETY FIELD
Always verify the actual detection field width by walk-testing according to ANSI 156.10.
SETUP
STEP OUT OF THE INFRARED FIELD!
SETUP 1 (QUICK)
reference picture either hold the knob for 2 seconds, or use the remote control buttons as specified
SETUP 2 (ASSISTED)
test of full door cycle + reference picture either hold the knob for 4 seconds, or use the remote control buttons as specified
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
COLORS
![]() |
(green) Motion detection |
![]() |
(red) Presence detection |
LED SIGNALS
BEHAVIORS
![]() |
LED flashes | ![]() |
LED flashes red-green |
![]() |
LED flashes quickly | ![]() |
LED is off |
![]() |
LED flashes x times |
OVERVIEW OF SETTINGS
Download the BEA DECODER app for a quick overview of settings
RESET LOG PASSWORD ADMIN
delete all saved errors LCD and remote control password (0000= no password) enter code to access admin mode
Note 1 | Always use a screwdriver when making further AIR adjustments to the arrow position on the sensor. | |
Note 2 | RADAR | AIR |
NO = normally open NC = normally closed DeEner = de-energized relay (active) Energ = energized relay (passive) |
NO = normally open NC = normally closed | |
Note 3 | The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control. |
|
Note 4 | MTF = uni-directional with motion-tracking feature uni + reentry: BEA recommends only adjusting using the LCD |
|
Note 5 | Auto mode evaluates traffic rate and adjusts hold time from 0.5 to 3 seconds | |
Note 6 | REDIRECTION setting (F1 on remote control): | |
R1-MW, R2-IR (f1=0): R1 = MW (i.e. motion detection) R2 = IR (i.e. presence detection) |
R1-MW or IR, R2-IR (F1=1): R1 = MW or IR (i.e. motion or presence detection) R2 = IR (i.e. presence detection) |
|
Note 7 | partial: outputs are not reset |
TECHNICAL SPECIFICATIONS
Relay 1 | Relay 2 | |
Output | Electromechanical relay (potential and polarity free) Max. contact current: 1 A Max. contact voltage: 30 VAC Adjustable hold time: 0.5 – 9 s |
Solid-state relay (potential and polarity free) Max. contact current: 100 mA Max. contact voltage: 42 VDC / 30 VAC |
Test/Monitoringinput: | Sensitivity: Low: < 1 V High: > 10 V (max. 30 V) Response time on test request: typical < 5 ms |
|
Supply voltage: | 12 – 24 VAC ±10% 12 – 30 VDC ±10% to be operated from SELV-compatible power supplies only |
|
Mounting height: | 6’6” – 11’6” local regulations may impact acceptable mounting height (pedestrian applications only) |
Specifications are subject to change without prior notice.
All values measured in specific conditions.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/ gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g.
ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
A Halima Company
Tech Support: 1-800-407-4545
Customer Service: 1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com
www.BEAsensors.com
75.1219.02 IXIO-DT1 QG 20240722
©BEA | Original Instructions
PLEASE KEEP FOR FUR THER USE
DESIGNED FOR COLOR PRINTING
Documents / Resources
![]() |
BEA DT1 Motion And Presence Sensor For Automatic Sliding Doors [pdf] User Guide DT1 Motion And Presence Sensor For Automatic Sliding Doors, DT1, Motion And Presence Sensor For Automatic Sliding Doors, Presence Sensor For Automatic Sliding Doors, For Automatic Sliding Doors, Automatic Sliding Doors, Sliding Doors, Doors |