B-TECH-LOGO

B-TECH DD 700 Weighing Terminal

B-TECH DD 700 Weighing Terminal-FIG1

Unpacking and Installation

Take the terminal, quick start guide, USB with manual, and sealing screws out of the package.

B-TECH DD 700 Weighing Terminal-FIG2 B-TECH DD 700 Weighing Terminal-FIG3

Available connections

  • A. Optional board slots
  • B. Scale 1
  • C. COM1 port
  • D. COM2 port
  • E. Terminal board for I/O.
  • F. Serial USB port
  • G. HOST USB port
  • H Power supply 12 V (by means of external power supply)
  • I Digital scale (optional) or Analog scale 2 (optional)
  • J. Calibration Switch
  • K. N/A
  • L. 12V Power Supply Input

Install the terminal. Press B-TECH DD 700 Weighing Terminal-FIG4 to turn on the terminal.

Display

B-TECH DD 700 Weighing Terminal-FIG5 Stable weight B-TECH DD 700 Weighing Terminal-FIG10  

Zero

B-TECH DD 700 Weighing Terminal-FIG6  

Tare

B-TECH DD 700 Weighing Terminal-FIG11 Tare

entered from keyboard

B-TECH DD 700 Weighing Terminal-FIG7 Minimum weight B-TECH DD 700 Weighing Terminal-FIG12 Gross weight in pounds
B-TECH DD 700 Weighing Terminal-FIG8 Weighing range indication B-TECH DD 700 Weighing Terminal-FIG13  

Net weight

B-TECH DD 700 Weighing Terminal-FIG9 Weight within range indication B-TECH DD 700 Weighing Terminal-FIG14 Weight below range indication
    B-TECH DD 700 Weighing Terminal-FIG15 Weight above range indication

Keyboard

B-TECH DD 700 Weighing Terminal-FIG16  

Zero scale

B-TECH DD 700 Weighing Terminal-FIG20 Entering and deleting tare weight
B-TECH DD 700 Weighing Terminal-FIG17 Entering and deleting tare weight B-TECH DD 700 Weighing Terminal-FIG21 Printing and/ or starting transmission
B-TECH DD 700 Weighing Terminal-FIG18 Customizable

keys

B-TECH DD 700 Weighing Terminal-FIG22  

Enter

B-TECH DD 700 Weighing Terminal-FIG19 Alphanumeric keys and symbols B-TECH DD 700 Weighing Terminal-FIG23 On/Off

Truck In and Out (ID#)

Inbound

  • Truck pulls on scale (light or heavy)
  • Press “I.D. #” key ( B-TECH DD 700 Weighing Terminal-FIG24on keypad)
  • Key in truck’s ID# (keys are alphanumeric like cellphone, so you may have to press a key repeatedly toget desired character or use the USB keyboard)
  • Press Enter B-TECH DD 700 Weighing Terminal-FIG25 key
  • Display returns to weight on scale withExample “RcD ID: 1234” below the weight.
  • Press Print B-TECH DD 700 Weighing Terminal-FIG26 key.
  • Ticket prints with time, date, ID# and inbound weight

Outbound

  • Truck returns to scale (heavy or light)
  • Press “I.D.#” key ( B-TECH DD 700 Weighing Terminal-FIG24key on keypad)
  • Key in truck’s ID# **If ID# is the same, just pressENTER, you don’t have to key it in again.**
  • Press Enter B-TECH DD 700 Weighing Terminal-FIG25 key
  • Display returns to weight on scale with
    Example “RcD ID: 1234” and “Inbound W eight: 15000lb” below it.
  • Press Print B-TECH DD 700 Weighing Terminal-FIG26 key.
  • Ticket prints with time, date, ID# and Gross, Tare, andNet weights.
    **After outbound print, truck ID# is erased from memory and can be used again.**

800.266.8900 • Fax: 330.471.8909 Monday – Friday 7:00 AM – 5:00 PM www.B-TEK.com • sales@b-tek.com Technical Support: 330 754-3880 x2

B-TECH DD 700 Weighing Terminal-FIG27

Connection of Analog Load Cells (Female DB9 Connector

B-TECH DD 700 Weighing Terminal-FIG28

COM1 & COM2 Serial Port Connection in RS232 (Male DB9 Connector)

B-TECH DD 700 Weighing Terminal-FIG29

Connection of COM2 in RS422 Configuration (Male DB9 Connector)

B-TECH DD 700 Weighing Terminal-FIG30

800.266.8900 • Fax: 330.471.8909 Monday – Friday 7:00 AM – 5:00 PM www.B-TEK.com • sales@b-tek.com Technical Support: 330 754-3880 x2

Documents / Resources

B-TECH DD 700 Weighing Terminal [pdf] User Guide
DD 700, Weighing Terminal, DD 700 Weighing Terminal, Terminal

References

Leave a comment

Your email address will not be published. Required fields are marked *