Autonics - logoMT4Y Series Digital Panel Meter
Instruction Manual

Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • Warning icon  symbol indicates caution due to special circumstances in which hazards may occur.

Warning icon Warning Failure to follow instructions may result in serious injury or death.

  1.  Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime / disaster prevention devices, etc.)
    Failure to follow this instruction may result in personal injury, economic loss or fire.
  2. Do not use the unit in the place where flammable / explosive / corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present.
    Failure to follow this instruction may result in explosion or fire.
  3. Install on a device panel to use. Failure to follow this instruction may result in fire or electric shock.
  4. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire or electric shock.
  5. Check ‘Connections’ before wiring. Failure to follow this instruction may result in fire.
  6. Do not disassemble or modify the unit. Failure to follow this instruction may result in fire or electric shock.

Warning icon  Caution Failure to follow instructions may result in injury or product damage.

  1. When connecting the power / measurement input and relay output, use AWG 24 (0.20 mm2) to AWG 15 (1.65 mm2)cable or over and tighten the terminal screw with a tightening torque of 0.98 to 1.18 N m. Use the wiring suitable for the load current capacity. Failure to follow this instruction may result in fire or malfunction due to contact failure.
  2. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage.
  3. Use a dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire or electric shock.
  4.  Keep the product away from metal chip, dust, and wire residue which flow into the unit. Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
  • Power supply should be insulated and limited voltage / current or Class 2, SELV power supply device.
  • Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
  • Use twisted pair wire for communication line.
  • Keep away from high voltage lines or power lines to prevent inductive noise.
    In case installing power line and input signal line closely, use line filter or varactor at power line and shielded wire at input signal line.
    Do not use near the equipment which generates strong magnetic force or high frequency noise.
Connection with the line filter Connection with the varactor
Autonics MT4Y Series Digital Panel Meter - line filtar Autonics MT4Y Series Digital Panel Meter - panel meter
  • This unit may be used in the following environments.
    – Indoors (in the environment condition rated in ‘Specifications’)
    – Altitude max. 2,000 m
    – Pollution degree 2
    – Installation category II

Ordering Information

This is only for reference, the actual product does not support all combinations. For selecting the specified model, follow the Autonics website.Autonics MT4Y Series Digital Panel Meter - icon

Input type
DV: DC voltage 01)
DA: DC current
AV: AC voltage 02)
AA: AC current 02)
Preset output + Sub output

Preset output Sub output
N None (indicator)
0 Relay
1 NPN open collector
2 PNP open collector
3 Relay (Low out) Transmission (DC 4 – 20 mA)
4 Relay (Low out) RS485 Communication
5 BCD Dynamic
6 Low speed serial
  1. To measure the current over DC 5 A, please select DV type because the shunt should be used.
  2. In case of selecting frequency display, no output will be provided even if it is output support model

Product Components

  • Product
  • Bracket × 2
  • Instruction manual
  • Unit sticker × 1

Manual
For proper use of the product, refer to the manuals and be sure to follow the safety considerations in the manuals.
Download the manuals from the Autonics website.
Software
Download the installation file and the manuals from the Autonics website.
Demister
It is the comprehensive device management program for Autonics’ products, providing parameter setting, monitoring and data management.
Dimensions

  • Unit: mm, For the detailed drawings, follow the Autonics website.

Autonics MT4Y Series Digital Panel Meter - dimensionCautions during Wiring
Use the Copper-conductor wire with the temperature class 60 ℃.

  • Unit: mm, Use terminals of size specified below.
  • Contact the manufacture for the socket and cable.

Autonics MT4Y Series Digital Panel Meter - cautions during

Hirose connector HIF3BA-14D-2.54R
Hirose connector socket HIF3BA-14PA-2.54DS
2 14

Autonics MT4Y Series Digital Panel Meter - icon 1

Connections

InputAutonics MT4Y Series Digital Panel Meter - inputOutputAutonics MT4Y Series Digital Panel Meter - output6: Low speed serial
POL: When a display value is (-) the signal of (-) will be outputted.Autonics MT4Y Series Digital Panel Meter - low speed

Specifications

Model MT4Y-DV-4□ MT4Y-DA-4□ MT4Y-AV-4□ MT4Y-AA-4□
Input type DC voltage DC current AC voltage 01) AC current 01)
Max. allowable input 110 % F.S. for each measured input range
Display method 7-segment (red) LED (character height: 14.2 mm)
Display accuracy Dependent on the ambient temperature
23 ± 5 ℃ ± 0.1 % F.S. rdg ± 2 digit ± 0.1 % F.S. rdg ± 2 digit 02) ± 0.3 % F.S. rdg ± 3 digit ± 0.3 % F.S. rdg ± 3 digit
-10 to 50 ℃ ± 0.5 % F.S. rdg ± 3 digit
Max. display range -1999 to 9999 (4 digit)
A / D conversion method ΣΔ (Sigma Delta) ADC
Sampling cycle 50 ms 16.6 ms
Unit weight (packaged) ≈ 134 g (≈ 213.5 g)
Approval Autonics MT4Y Series Digital Panel Meter - icon 2

 

  1. Available frequency display, Display accuracy (23 ± 5 ℃): ± 0.1 % F.S. rdg ± 2 digit
  2. 5 A terminal: ± 0.3 % F.S. rdg ± 3 digit
Preset output None (indicator) / Relay / NPN open collector / PNP open collector output model
Relay Contact capacity: 250 VACART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 3 A, 30 VDCART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 3 A Contact composition: N.O (1a)
NPN / PNP open collector Output capacity: ≤ 12 – 24 VDCART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 ± 2 VDCART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3, 50 mA resistive load
Sub output None (indicator) / BCD Dynamic / Transmission (DC 4 – 20 mA) / Low speed serial / RS485 Communication output model
BCD Dynamic / Low speed serial NPN open collector output Output capacity: ≤ 12 – 24 VDC, 50 mA resistive load
Transmission (DC 4 – 20 mA) Resolution: 1/12,000 (load resistance: ≤ 600 Ω) Response time: ≤ 450 ms
RS485 communication Protocol: Modbus RTU
Power supply 100 – 240 VACART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 ± 10 % 50 / 60 Hz
Power consumption 5 VA
Insulation resistance Between external terminal and case: ≥ 100 MΩ (500 VDCART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 megger)
Dielectric strength Between external terminal and case: 2,000 VACART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 50 / 60 Hz for 1 min
Noise immunity ± 2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
Vibration 0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Vibration (malfunction) 0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 10 min
Shock 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (malfunction) 100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times
Relay life cycle Mechanical: ≥ 20,000,000 operations
Electrical: ≥ 100,000 operations (250 VACART SOUND ARBT76 Prisma Cube LED Wireless Speaker - icon 3 3A resistive load)
Ambient temp. -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humi. 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Insulation type Symbol: , double or reinforced insulation (dielectric strength between the measurement input part and the power part: 1 kV)

Communication Interface
RS485

Comm. protocol Modbus RTU
Application standard Compliance with EIA RS485
Max. connection 31 units (address: 01 to 99)
Comm. synchronous method Asynchronous
Comm. method 2-wire half duplex
Comm. distance ≤ 800 m
Comm. speed 1,200 / 1,400 / 4,800 / 9,600 / 19,200 / 38,400 bps
Start bit 1-bit (fixed)
Data bit 8-bit (fixed)
Parity bit None, Even, Odd
Stop bit 1-bit, 2-bit
EEPROM life cycle ≈ 1,000,000 operations (Erase / Write)

Mode SettingAutonics MT4Y Series Digital Panel Meter - mode setting

Parameter Setting

  • Some parameters are activated / deactivated depending on the model or setting of other parameters. Refer to the description of each parameter.
  • If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
  • After returning to RUN mode, press the [MODE] key within 2 sec, it returns to previous parameter.
  • [MODE] key: Saves current setting value and moves to the next parameter. [◀] key: Checks fixed value / Changes setting digits. [▲], [▼] key: Changes setting values.

Parameter 1 group

Parameter Mark Defaults Setting range Display condition
1-1 Input range Autonics MT4Y Series Digital Panel Meter - icon 3 Autonics MT4Y Series Digital Panel Meter - icon 17 [DC voltage model], [AC voltage model] • Refer to Input Range and Display Range

Autonics MT4Y Series Digital Panel Meter - icon 18

[DC current model], [AC current model] • Refer to Input Range and Display Range
1-2 Display method Autonics MT4Y Series Digital Panel Meter - icon 4 Autonics MT4Y Series Digital Panel Meter - icon 19 STND: standard, SCAL: scale, FREQ: frequency 01)
1-3  Measurement method Autonics MT4Y Series Digital Panel Meter - icon 5 Autonics MT4Y Series Digital Panel Meter - icon 20 [AC voltage model], [AC current model] T.RMS: True RMS, A.RMS: Average RMS, AVG 
•   True RMS = Autonics MT4Y Series Digital Panel Meter - icon 28
•  Average RMS =Autonics MT4Y Series Digital Panel Meter - icon 29
(n = number of display values per cycle, A = display value)
1-2 Display method: STND, SCAL
Max. display 1-4 value (fixed) Autonics MT4Y Series Digital Panel Meter - icon 6 Autonics MT4Y Series Digital Panel Meter - icon 21 [DC voltage model], [AC voltage model] Max. value of display range 1-2 Display method: STND
 

Autonics MT4Y Series Digital Panel Meter - icon 22

[DC current model], [AC current model] Max. value of display range
High-limit 1-5 display value gradient
correction
Autonics MT4Y Series Digital Panel Meter - icon 7 Autonics MT4Y Series Digital Panel Meter - icon 23 0.100 to 5.000 %
Low-limit 1-6 display value deviation
correction
Autonics MT4Y Series Digital Panel Meter - icon 13 Autonics MT4Y Series Digital Panel Meter - icon 24 -99 to 99
Decimal1-7 point position Autonics MT4Y Series Digital Panel Meter - icon 9 Autonics MT4Y Series Digital Panel Meter - icon 25 [DC voltage model], [AC voltage model] 0, 0.0, 0.00, 0.000 1-2 Display method: SCAL & * 1-7 Decimal point position: 0.0, 0.00, 0.000
Autonics MT4Y Series Digital Panel Meter - icon 26 [DC current model], [AC current model] 0, 0.0, 0.00, 0.000
1-8 High-limit scale Autonics MT4Y Series Digital Panel Meter - icon 10 Display value against max. measurement input*
1-9 Low-limit scale Autonics MT4Y Series Digital Panel Meter - icon 11 Display value against min. measurement input*
High-limit 1-10 display value gradient
correction
Autonics MT4Y Series Digital Panel Meter - icon 11 Autonics MT4Y Series Digital Panel Meter - icon 23 0.100 to 5.000 %
Low-limit 1-11 display value deviation
correction 02)
Autonics MT4Y Series Digital Panel Meter - icon 8 Autonics MT4Y Series Digital Panel Meter - icon 24 w-99 to 99
Decimal 1-12 point position 03) Autonics MT4Y Series Digital Panel Meter - icon 14 Autonics MT4Y Series Digital Panel Meter - icon 25 [AC voltage model] 0, 0.0, 0.00, 0.000 1-2 Display method: FREQ
Autonics MT4Y Series Digital Panel Meter - icon 26 [AC current model] 0, 0.0, 0.00, 0.000
High-limit 1-13 display value gradient
correction
Autonics MT4Y Series Digital Panel Meter - icon 15 Autonics MT4Y Series Digital Panel Meter - icon 23 0.100 to 9.999
1-14 Exponent of INB Autonics MT4Y Series Digital Panel Meter - icon 16 Autonics MT4Y Series Digital Panel Meter - icon 27 10-0: 100, 10-1: 10-1, 10-2: 10-2, 10 1: 101

 

  1. Displays at AC voltage or AC current model only.
  2. Low-limit display value deviation correction range is within -99 to 99 for D0, D-1
  3. Display range is variable according to decimal point position.
Dot Display range Frequency measurement range
Autonics MT4Y Series Digital Panel Meter - icon 30 -1999 to 9999 1 to 9999 Hz
Autonics MT4Y Series Digital Panel Meter - icon 31 -199.9 to 999.9 0.1 to 999.9 Hz
Autonics MT4Y Series Digital Panel Meter - icon 32 -19.99 to 99.99 0.10 to 99.99 Hz
Autonics MT4Y Series Digital Panel Meter - icon 33 -1.999 to 9.999 0.100 to 9.999 Hz

Parameter 2 group

Parameter Mark Defaults Setting range Display condition
 2-1  Output operation mode

Autonics MT4Y Series Digital Panel Meter - icon 34

Autonics MT4Y Series Digital Panel Meter - icon 51

[Except indicator model] OFF, L.ST, H.ST, LH.ST, HH.ST, LL.ST, LD.ST
•    Refer to Output Operation Mode
•    Relay (Low out) output model is available only OFF or L.ST.
 
 

2-2

 Hysteresis

Autonics MT4Y Series Digital Panel Meter - icon 35

Autonics MT4Y Series Digital Panel Meter - icon 52

 [Except indicator model] Within 10 % of max. display range, digit 2-1 Output operation mode: except OFF
 2-3 Startup compensation time

Autonics MT4Y Series Digital Panel Meter - icon 36

Autonics MT4Y Series Digital Panel Meter - icon 53

[Except indicator model] 0.0 to 99.9 sec  
 2-4 Peak monitoring delay time

Autonics MT4Y Series Digital Panel Meter - icon 37

Autonics MT4Y Series Digital Panel Meter - icon 54

 00 to 30 sec  
2-5 Display cycle Autonics MT4Y Series Digital Panel Meter - icon 128 Autonics MT4Y Series Digital Panel Meter - icon 55 0.1 to 5.0 sec
 2-6 Keys for zero adjustment

Autonics MT4Y Series Digital Panel Meter - icon 39

Autonics MT4Y Series Digital Panel Meter - icon 56

NO, YES

•  YES: Press the [◀] + [▲] keys for 3 sec to adjust zero.

 
 2-7  External input terminal

Autonics MT4Y Series Digital Panel Meter - icon 40

Autonics MT4Y Series Digital Panel Meter - icon 57

[Except indicator model] HOLD, ZERO
•  If the external input terminal is short-circuited for 50 ms or more, it operates with the set function.
 
 2-8  High-limit value of transmission output

Autonics MT4Y Series Digital Panel Meter - icon 42

Autonics MT4Y Series Digital Panel Meter - icon 58

[DC voltage & Transmission (DC 4 – 20 mA) output model], [AC voltage & Transmission (DC 4 – 20 mA) output model] Max. value of display range  
Autonics MT4Y Series Digital Panel Meter - icon 59 [DC current & Transmission (DC 4 – 20 mA) output model], [AC current & Transmission (DC 4 – 20 mA) output model] Max. value of display range
 2-9  Low-limit value of transmission output

Autonics MT4Y Series Digital Panel Meter - icon 43

Autonics MT4Y Series Digital Panel Meter - icon 60 [DC voltage & Transmission (DC 4 – 20 mA) output model], [AC voltage & Transmission (DC 4 – 20 mA) output model] Min. value of display range  

Autonics MT4Y Series Digital Panel Meter - icon 32

[DC current & Transmission (DC 4 – 20 mA) output model], [AC current & Transmission (DC 4 – 20 mA) output model] Min. value of display range
2-10 Comm. Address Autonics MT4Y Series Digital Panel Meter - icon 44 Autonics MT4Y Series Digital Panel Meter - icon 61 [RS485 Comm. output model] 01 to 99
2-11 Comm. speed Autonics MT4Y Series Digital Panel Meter - icon 45 Autonics MT4Y Series Digital Panel Meter - icon 62 [RS485 Comm. output model] 38.4k, 19.2k, 9600, 4800, 2400, 1200 bps
2-12 Parity bit Autonics MT4Y Series Digital Panel Meter - icon 46 Autonics MT4Y Series Digital Panel Meter - icon 63 [RS485 Comm. output model] NONE, EVEN, ODD
2-13 Stop bit Autonics MT4Y Series Digital Panel Meter - icon 129 Autonics MT4Y Series Digital Panel Meter - icon 64 [RS485 Comm. output model] 2, 1 bit
2-14 Response waiting time Autonics MT4Y Series Digital Panel Meter - icon 48 Autonics MT4Y Series Digital Panel Meter - icon 65 [RS485 Comm. output model] 5 to 99 sec
 2-15  Lock

Autonics MT4Y Series Digital Panel Meter - icon 50

Autonics MT4Y Series Digital Panel Meter - icon 51

OFF: unlock, LOC1: lock parameter 1, LOC2: lock parameter 1, 2, LOC3: lock parameter 0, 1 and 2  

Parameter 0 group

Parameter Mark Defaults Setting range Display condition
Output high- 0-1 limit output
setting value
Autonics MT4Y Series Digital Panel Meter - icon 130 Autonics MT4Y Series Digital Panel Meter - icon 71 [DC voltage & Preset setting model] -5 to 110 % of display range
[AC voltage & Preset setting model] 0 to 110 % of display range
2-1 Output operation mode: except OFF
Autonics MT4Y Series Digital Panel Meter - icon 72 [DC current & Preset setting model] -5 to 110 % of display range
[AC current & Preset setting model] 0 to 110 % of display range
 Output low- 0-2 limit output
setting value

Autonics MT4Y Series Digital Panel Meter - icon 131

Autonics MT4Y Series Digital Panel Meter - icon 73 [DC voltage & Preset setting model] -5 to 110 % of display range
[AC voltage & Preset setting model] 0 to 110 % of display range
2-1 Output operation mode: except OFF
Autonics MT4Y Series Digital Panel Meter - icon 73 [DC current & Preset setting model] -5 to 110 % of display range
[AC current & Preset setting model] 0 to 110 % of display range
 0-3   Display max. peak value 01)

Autonics MT4Y Series Digital Panel Meter - icon 69

Autonics MT4Y Series Digital Panel Meter - icon 31 [DC voltage], [AC voltage] Max. peak value in run mode 2-1 Output operation mode: except
Autonics MT4Y Series Digital Panel Meter - icon 73 [DC current], [AC current] Max. peak value in run mode
OFF & 2-4 Peak monitoring delay time: except 00
 0-4   Display min. peak value 01) Autonics MT4Y Series Digital Panel Meter - icon 70 Autonics MT4Y Series Digital Panel Meter - icon 31 [DC voltage], [AC voltage] Min. peak value in run mode
Autonics MT4Y Series Digital Panel Meter - icon 73 [DC current], [AC current] Min. peak value in run mode

Input Range and Display Range

When the max. input value is over the 100 %, it may result in input terminal damage.
DC voltage model

Input range Display range Input impedance
Diaplay method: STND (fixed) Diaplay method: SCAL “)
0 – 500 VDC= 0.0 to 500.0 Autonics MT4Y Series Digital Panel Meter - icon 91
Decimals Display range
Autonics MT4Y Series Digital Panel Meter - icon 30 -1999 to 9999
Autonics MT4Y Series Digital Panel Meter - icon 31 -199.9 to 999.9
Autonics MT4Y Series Digital Panel Meter - icon 32 -19.99 to 99.99
Autonics MT4Y Series Digital Panel Meter - icon 33 -1.999 to 9.999
4.33 M O
0- 100 VDC= 0.0 to 100.0 Autonics MT4Y Series Digital Panel Meter - icon 76 4.33 M0
0 – 50 VDC— 0.00 to 50.00 Autonics MT4Y Series Digital Panel Meter - icon 77 433.48 kG
0 -10 VDC— 0.00 to 10.00 Autonics MT4Y Series Digital Panel Meter - icon 78 433.48 k0
0 – 5 VDC— 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 79 43.48 kO
0 -1 VDC— 0.000 to 1.000 Autonics MT4Y Series Digital Panel Meter - icon 80 43.48k0
0 – 250 mVDC= 0.0 to 250.0 Autonics MT4Y Series Digital Panel Meter - icon 81 2.28 kC)
0 – 50 mVDC= 0.00 to 50.00 Autonics MT4Y Series Digital Panel Meter - icon 82 2.28 kC)

01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

DC current model

Input range Display range Input impedance
Diaplay method: STND (fixed) Diaplay method: SCAL (11)
0 – 5 A 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 83
Decimals Display range
Autonics MT4Y Series Digital Panel Meter - icon 30 -1999 to 9999
Autonics MT4Y Series Digital Panel Meter - icon 31 -199.9 to 999.9
Autonics MT4Y Series Digital Panel Meter - icon 32 -19.99 to 99.99
Autonics MT4Y Series Digital Panel Meter - icon 33 -1.999 to 9.999
0.020
0 – 2 A 0.000 to 2.000 Autonics MT4Y Series Digital Panel Meter - icon 84 0.020
0 – 500 mA 0.0 to 500.0 Autonics MT4Y Series Digital Panel Meter - icon 85 0.220
0 – 200 mA 0.0 to 200.0 Autonics MT4Y Series Digital Panel Meter - icon 86 0.220
0 – 50 mA 0.00 to 50.00 Autonics MT4Y Series Digital Panel Meter - icon 87 2.220
4 – 20 mA 4.00 to 20.00 Autonics MT4Y Series Digital Panel Meter - icon 88 2.220
0 – 5 mA 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 89 22.220
0 – 2 mA 0.000 to 2.000 Autonics MT4Y Series Digital Panel Meter - icon 90 22.220

01) Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

AC voltage model

Input range Display range Input impedance
Diaplay method: STND (fixed) Diaplay method: SCAL 01)
0 – 5 A 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 91
Decimals Display range
Autonics MT4Y Series Digital Panel Meter - icon 30 -1999 to 9999
Autonics MT4Y Series Digital Panel Meter - icon 31 -199.9 to 999.9
Autonics MT4Y Series Digital Panel Meter - icon 32 -19.99 to 99.99
Autonics MT4Y Series Digital Panel Meter - icon 33 -1.999 to 9.999
0.020
0 – 2 A 0.000 to 2.000 Autonics MT4Y Series Digital Panel Meter - icon 92 0.020
0 – 500 mA 0.0 to 500.0 Autonics MT4Y Series Digital Panel Meter - icon 93 0.220
0 – 200 mA 0.0 to 200.0 Autonics MT4Y Series Digital Panel Meter - icon 94 0.220
0 – 50 mA 0.00 to 50.00 Autonics MT4Y Series Digital Panel Meter - icon 95 2.220
4 – 20 mA 4.00 to 20.00 Autonics MT4Y Series Digital Panel Meter - icon 96 2.220
0 – 5 mA 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 97 22.220
0 – 2 mA 0.000 to 2.000 Autonics MT4Y Series Digital Panel Meter - icon 98 22.220
  1. Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input range to measure.
    When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
  2. In case of 0 to 110 VAC of AC voltage range and using P.T (potential transformer) for 440 VAC/ 110 VAC, if 110 VAC is input, and the unit displays 440 VAC automatically by preset scale value for P.T user’s convenient.

AC current model

Input range Display range Input impedance
Diaplay method: STND (fixed) Diaplay method: SCAL °I)
0- 5 A 0.000 to 5.000 Autonics MT4Y Series Digital Panel Meter - icon 99
Decimals Display range
Autonics MT4Y Series Digital Panel Meter - icon 30 -1999 to 9999
Autonics MT4Y Series Digital Panel Meter - icon 31 -199.9 to 999.9
Autonics MT4Y Series Digital Panel Meter - icon 32 -19.99 to 99.99
Autonics MT4Y Series Digital Panel Meter - icon 33 -1.999 to 9.999
0.020
0 – 2.5 A 0.000 to 2.500 Autonics MT4Y Series Digital Panel Meter - icon 100 0.020
0 – 1 A 0.000 to 1.000 Autonics MT4Y Series Digital Panel Meter - icon 101 0.100
0 – 500 mA 0.0 to 500.0 Autonics MT4Y Series Digital Panel Meter - icon 102 0.200
0 – 250 mA 0.0 to 250.0 Autonics MT4Y Series Digital Panel Meter - icon 104 0.200
0 -100 mA 0.0 to 100.0 Autonics MT4Y Series Digital Panel Meter - icon 105 1.020
0 – 50 mA 0.00 to 50.00 Autonics MT4Y Series Digital Panel Meter - icon 106 1.020

Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input range to measure.
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

Output Operation Mode

  • H.SET or L.SET is displayed according to the output operation mode setting. In case of output operation mode as OFF, H.SET and L.SET are not displayed.
  • When changing output operation mode, high-limit / low-limit output setting value, hysteresis are reset.
MODE Output operation Preset output
LO ON HI ON GO ON
Autonics MT4Y Series Digital Panel Meter - icon 121
Autonics MT4Y Series Digital Panel Meter - icon 51 Autonics MT4Y Series Digital Panel Meter - icon 114 No output
Autonics MT4Y Series Digital Panel Meter - icon 109 Autonics MT4Y Series Digital Panel Meter - icon 115 L.SET Display value L.SET < Display value
Autonics MT4Y Series Digital Panel Meter - icon 132 Autonics MT4Y Series Digital Panel Meter - icon 116 H.SET Display value H.SET > Display value
Autonics MT4Y Series Digital Panel Meter - icon 110 Autonics MT4Y Series Digital Panel Meter - icon 117 L.SET .- Display value H.SET Display value L.SET <  Display value< H.SET
Autonics MT4Y Series Digital Panel Meter - icon 111 Autonics MT4Y Series Digital Panel Meter - icon 118 L.SET :5_ Display value H.SET -. Display value L.SET > Display value
Autonics MT4Y Series Digital Panel Meter - icon 112 Autonics MT4Y Series Digital Panel Meter - icon 119 L.SET .- Display value H.SET Display value H.SET < Display value
Autonics MT4Y Series Digital Panel Meter - icon 113 Autonics MT4Y Series Digital Panel Meter - icon 120 Second L.SET Display value L.SET < Display value

Reset

  1. Press the [◀] + [▲] + [▼] keys for over 5 sec. in run mode, INIT flashes for 0.5 sec.
  2. Press the direction keys to flash NO for 0.5 sec in turn.
  3. Change the setting value as YES by pressing the direction keys.
  4. Press the [MODE] key to reset all parameter values as default and to return to run mode.

Error
Error display is released automatically when it is in the measured and display range.

Display Description Troubleshooting
Autonics MT4Y Series Digital Panel Meter - icon 122 Flashes when measurement input is exceeded the max. allowable input (110 %) Disconnect power supply and check the cables.
Autonics MT4Y Series Digital Panel Meter - icon 123 Flashes when measurement input is exceeded the min. allowable input (-10 %)
Autonics MT4Y Series Digital Panel Meter - icon 124 Turns ON when display input is exceeded high-limit scale setting value or max. display range (9999) Reset within the display range.
Autonics MT4Y Series Digital Panel Meter - icon 125 Turns ON when display input is exceeded low-limit scale setting value or min. display range (-1999)
Autonics MT4Y Series Digital Panel Meter - icon 126 Turns ON when input frequency is exceeded the max. display value of measured range
Autonics MT4Y Series Digital Panel Meter - icon 127 Flashes twice when it exceeds zero range (+99) and returns to run mode Reset within the zero range.

18, Bansong-ro 513Beon-gil, Haeundae-gu,
Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com

Documents / Resources

Autonics MT4Y Series Digital Panel Meter [pdf] Instruction Manual
MT4Y-AV-42, MT4Y Series Digital Panel Meter, Digital Panel Meter, Panel Meter, Meter

References

Leave a comment

Your email address will not be published. Required fields are marked *