Audio Enhancement MS-775 NetWork Interface User Guide

MS-775 NetWork Interface

Specifications

  • General Purpose I/O:
    • (4) Discrete Inputs
    • (4) Discrete Outputs
  • Serial Communication:
    • (1) RS-232 Connection
  • Audio:
    • (1) Balanced Audio Out
    • (1) Amplified Speaker Audio Out
    • (1) Mic Audio In
  • Remote Power:
    • (2) 24 V Out
  • Power: PoE+
  • Interfaces:
    • Remote Port (RMTCTRL)
    • Wall Plate Audio (WPA) Port
    • IO Output Port: Output 3, Output 4
    • IO Input Port: Input 3, Input 4
    • USB Port (for service only)

Product Usage Instructions

1. Installation

Physically install components in the room, such as speakers
and/or AV Touch Wall Control.

2. Dongle Connection

Confirm the dongle is connected to the USB port.

3. Power On

Turn the amplifier on by connecting to PoE+.

4. System Setup

Start EPIC System, update the firmware, and continue the setup
using the EPIC System software.

Configuration Set Up in EPIC System

Follow the instructions in the EPIC System Admin Manual –
Managing Devices. Click or Scan QR code to access.

FAQ

Troubleshooting

Reboot

Press and hold the Reboot button for 5 seconds.

Factory Reset Procedure

Press and hold the Factory Reset button until the Activity
Indicator flashes green (10 seconds) and then release.

Rescue Mode

Press and hold the Reboot button until the Activity Indicator
illuminates red (15 seconds) and then release. Or disconnect PoE+
power, press and hold the Reboot button while applying PoE+
power.

No Audio

If there is no audio going through the speakers (bells, paging,
intercom) check the audio output to see if there is any audio
passing through there. This can be done by connecting a pair of
wired headphones to the audio out of the MS-775 and playing audio
through the MS-775. If you hear audio through the headphones, it is
most likely not a problem with the MS-775, and related to the
speakers or speaker wiring.

DC-41101.0625

MS-775 NETWORK INTERFACE
QUICK START GUIDE

PoE+ RmtCtrl Reboot/Factory Default

Discrete Outputs 3 and 4

USB Port WPA-70x Discrete Inputs 3 and 4 Speaker Out Unit Status GPIO Status

DESCRIPTION
The MS-775 Network Interface for SAFE Alert Extender is a fully integrated networked paging interface, ideal for delivering audio in small rooms. It supports network-based intercom, paging, and emergency notification, with an intuitive, easy-to-install design. Powered by Power over Ethernet+ (PoE+), it enables full-duplex SIP communication, and when connected to an Uninterruptible Power Supply (UPS), it ensures paging remains operational during power outages or emergencies. The MS-775 can be integrated into the EPIC (Education Paging & Intercom Communications) System®, the SAFE (Signal Alert For Education) System®, or other compatible building systems. Unlike the MS-720, which focuses on standard intercom and paging functions, the MS-775 also supports non-paired alerts from the XD Teacher Microphone and XD Alert Badge, enhancing its effectiveness for emergency communication.
FUNCTIONAL SUMMARY

GENERAL PURPOSE I/O

·

(4) Discrete Inputs

·

(4) Discrete Outputs

SERIAL COMMUNICATION

·

(1) RS-232 Connection

AUDIO

·

(1) Balanced Audio Out

·

(1) Amplified Speaker Audio Out

·

(1) Mic Audio In

2

REMOTE POWER

·

(2) 24 V Out

POWER

·

PoE+

INTERFACES

REMOTE PORT (RMTCTRL)

·

Audio Out (Balanced)

·

RS-232

·

24 V DC

·

(1) Mic In (Balanced)

WALL PLATE AUDIO (WPA) PORT

·

Connects to the ITC2

IO OUTPUT PORT

·

Output 3

·

Output 4

IO INPUT PORT

·

Input 3

·

Input 4

USB PORT (FOR SERVICE ONLY)

RESET BUTTON

LEDS

Ready

·

Green – Powered on

·

Red – Booting

Activity

·

Off – No active event

·

Red – Active event

GPIO (General Purpose I/O)

·

Yellow – Input active

·

Blue – Output active

·

White – Input & output active

SPEAKER CONNECTION

·

Speaker Out

ETHERNET

·

PoE+ Port

3

PROCESS

1.

Physically install components in the room, such as speakers and/or AV Touch Wall Control.

2. Confirm dongle is connected to USB port.

3. Turn the amplifier on by connecting to PoE+.

4. Start EPIC System, update the firmware, and continue the setup using the EPIC System software.

CONFIGURATION SET UP IN EPIC SYSTEM
Follow the instructions in the EPIC System Admin Manual – Managing Devices. Click or Scan QR code to access.

4

CONNECTOR DETAILS

WPA Remote Control

RMTCTRL PORT
1 2 3 4 5 6 7 8

+Line Level Output -Line Level Output RS-232 – TXD +24 V DC GND RS-232 – RXD +Mic In -Mic In

WALL PLATE AUDIO

+Mic In

1

-Mic In

2

I/O In #1 (Call)

3

4

+24 V DC

5

GND

6

I/O In #2 (Emergency)

7 8

I/O IOut #1

I/O IOut #2

5

TROUBLESHOOTING
REBOOT
Press and hold the Reboot button for 5 seconds.
FACTORY RESET PROCEDURE
Press and hold the Factory Reset button until the Activity Indicator flashes green (10 seconds) and then release.
RESCUE MODE
Press and hold the Reboot button until the Activity Indicator illuminates red (15 seconds) and then release. Or disconnect PoE+ power, press and hold the Reboot button while applying PoE+ power.
NO AUDIO
If there is no audio going through the speakers (bells, paging, intercom) check the audio output to see if there is any audio passing through there. This can be done by connecting a pair of wired headphones to the audio out of the MS-775 and playing audio through the MS-775. If you hear audio through the headphones, it is most likely not a problem with the MS-775, and related to the speakers or speaker wiring.

DC-41101.0625

AudioEnhancement.com · 800.383.9362

Documents / Resources

Audio Enhancement MS-775 NetWork Interface [pdf] User Guide
MS-775, MS-775 NetWork Interface, MS-775, NetWork Interface, Interface

References