dreame P-Wind10
DREAME P-Wind10 9000 BTU Portable Air Conditioner User Manual
Model: P-Wind10
1. Introduction
Thank you for choosing the DREAME P-Wind10 Portable Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your appliance. Please read it thoroughly before use and keep it for future reference.
2. Safety Instructions
To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions, including the following:
- Read all instructions before using this appliance.
- This appliance uses R290 refrigerant. R290 is a natural, environmentally friendly refrigerant, but it is also flammable. Keep the appliance away from open flames and other ignition sources.
- Ensure the power supply matches the voltage specified on the rating label.
- Do not operate the unit with a damaged cord or plug.
- Do not insert objects into the air outlet or inlet.
- Always unplug the unit before cleaning or servicing.
- Keep the unit upright during transport and operation.
- Do not block the air vents.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Product Overview
3.1. Key Features
- 3-in-1 Comfort: Offers Cooling, Dehumidification, and Fan modes for versatile climate control.
- Compact Design: With dimensions of 30.5 x 28.5 x 70 cm, it fits easily into various small spaces like bedrooms and home offices.
- Easy Installation & Mobility: Simple 3-step setup and four swivel wheels allow for effortless movement between rooms.
- Multiple Control Options: Control via LED display, remote control, or dedicated Wi-Fi app.
- R290 Refrigerant: Utilizes an environmentally friendly refrigerant with zero ozone depletion potential.
- 3D Airflow: Ensures uniform distribution of cool air throughout the room.
- Night Mode: Designed for quiet operation and reduced light for undisturbed sleep.
3.2. Package Contents
Verify that all components are present in the package:

Figure 1: Package Contents
- DREAME P-Wind10 Unit x 1
- Air Exhaust Hose x 1
- Hose Connector x 1
- Window Kit Adapter x 1
- Wing Bolt Set x 1
- Water Tube x 1
- Remote Control x 1
- Window Kit x 1
- User Manual x 1
4. Setup and Installation
The DREAME P-Wind10 is designed for easy, tool-free installation. Follow these three simple steps to set up your unit:
4.1. Step 1: Install the Window Kit Adapter
Slide the window kit adapter into the appropriate slot of your window. Ensure it is securely fitted to prevent air leakage.

Figure 2: Inserting the Window Kit Adapter
4.2. Step 2: Connect the Exhaust Hose to the Window Kit
Attach one end of the air exhaust hose to the window kit adapter. Twist or push until it is firmly connected.

Figure 3: Connecting Hose to Window Kit
4.3. Step 3: Connect the Exhaust Hose to the Unit
Connect the other end of the air exhaust hose to the hose connector on the DREAME P-Wind10 unit. Ensure all connections are tight to maximize efficiency.

Figure 4: Connecting Hose to Unit
Once installed, you can easily move the unit thanks to its integrated wheels, allowing you to cool different rooms as needed.

Figure 5: Effortless Mobility and Installation
5. Operating Modes
The DREAME P-Wind10 offers three primary operating modes to suit your comfort needs:
5.1. Cooling Mode
In Cooling Mode, the unit actively lowers the room temperature. Set your desired temperature using the control panel, remote, or app. The unit will operate to maintain this temperature.

Figure 6: Cooling Mode Operation
5.2. Dehumidification Mode
This mode reduces excess humidity in the air without significant cooling. Ideal for damp environments. The unit will collect moisture, which can be drained manually or continuously via the water tube.
5.3. Fan Mode
In Fan Mode, the unit circulates air without engaging the cooling or dehumidifying functions. Use this mode for gentle air circulation and ventilation.

Figure 7: 3-in-1 Comfort Modes
5.4. Night Mode
Activate Night Mode for quieter operation and dimmed display lights, promoting a more restful sleep environment. This mode typically adjusts temperature settings gradually for optimal comfort during the night.

Figure 8: Night Mode for Quiet Operation
5.5. 3D Airflow
The unit features 3D airflow distribution, ensuring cool air reaches all corners of the room evenly. Automatic horizontal oscillation and adjustable vertical airflow provide balanced air circulation.

Figure 9: 3D Airflow Distribution
6. Control Options
The DREAME P-Wind10 offers multiple ways to control its functions:
- LED Display: The integrated LED display on the unit allows for direct control and shows current settings.
- Remote Control: Use the included remote control for convenient operation from a distance.
- Dedicated App with Wi-Fi: Connect the unit to your home Wi-Fi and control it via the DREAME smartphone app. This allows for advanced scheduling and remote management.
- 24-Hour Timer: Program the unit to turn on or off automatically within a 24-hour period.

Figure 10: Multiple Control Options
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your DREAME P-Wind10 unit.
7.1. Cleaning the Air Filter
The air filter should be cleaned every two weeks or more frequently depending on usage. A dirty filter can reduce efficiency and airflow.
- Unplug the unit from the power outlet.
- Remove the air filter from the back or side of the unit (refer to the diagram in the full manual for exact location).
- Wash the filter with warm, soapy water. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it. Do not expose to direct sunlight.
7.2. Draining Water
The unit has an internal water tank for collected moisture. When the tank is full, the unit will stop operating and indicate that it needs draining.
- Manual Draining: Place a shallow pan under the drain port at the back of the unit. Remove the drain plug and allow water to flow out. Replace the plug when empty.
- Continuous Draining: For continuous dehumidification, connect the included water tube to the continuous drain port and direct it to a floor drain or suitable container.
7.3. Storage
If storing the unit for an extended period:
- Drain all water from the unit.
- Clean the air filter.
- Run the unit in fan mode for a few hours to dry the internal components.
- Unplug the power cord and wrap it neatly.
- Store the unit in an upright position in a cool, dry place, away from direct sunlight.
8. Troubleshooting
Before contacting customer support, please refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Power cord not plugged in; Full water tank. | Check power connection; Plug in power cord; Drain water tank. |
| Unit does not cool effectively | Dirty air filter; Blocked air intake/outlet; Room too large; Doors/windows open; Exhaust hose not properly installed. | Clean air filter; Clear obstructions; Ensure room size is within unit capacity; Close doors/windows; Check exhaust hose connection. |
| Unit is noisy | Unit not on a level surface; Air filter dirty; Internal components vibrating. | Place unit on a flat, stable surface; Clean air filter; If noise persists, contact support. |
| Water leakage | Drain plug loose; Continuous drain hose not properly connected. | Ensure drain plug is tight; Check continuous drain hose connection. |
| Remote control not working | Batteries dead or incorrectly inserted; Obstruction between remote and unit. | Replace batteries; Ensure correct polarity; Remove obstructions. |
9. Specifications
| Feature | Detail |
|---|---|
| Brand | dreame |
| Model Name | P-Wind10 |
| Model Number | PWIND10 |
| Product Type | Air Conditioning |
| Cooling Capacity | 9000 BTU |
| Operating Modes | Cooling, Dehumidifying, Air Circulation (Fan) |
| Special Features | Smart Control, Compact Design, 3D Airflow, Effortless Installation, Night Mode |
| Product Dimensions (D x W x H) | 30.5 x 28.5 x 70 cm |
| Color | Gold |
| Voltage | 12 Volt |
| Noise Level | 65 Decibels |
| Form Factor | Portable |
| Control Method | Remote, App, LED Display |
| Installation Type | Packaged |
| Outdoor Unit Required | No |
| Air Conditioner Application | Residential |
| Electrical Power | 2.6 kWh |
| Efficiency | A |
| Annual Energy Consumption | 1 Kilowatt-hour |
| Room Type | Bedroom and Office |
| Manufacturer | dreame |

Figure 11: R290 Eco-Friendly Refrigerant
10. Warranty and Support
10.1. Product Warranty
The DREAME P-Wind10 Portable Air Conditioner comes with a 3-year product warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.
10.2. Customer Support
For technical assistance, warranty service, or any questions regarding your DREAME P-Wind10, please contact DREAME customer support. Refer to the official DREAME website or the contact information provided in your purchase documentation for the most up-to-date support channels.
When contacting support, please have your model name (P-Wind10) and serial number (if applicable) ready.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.




