TBK 958ZE

TBK958ZE UV Laser Machine User Manual

Model: 958ZE | Brand: TBK

1. Introduction and Overview

The TBK958ZE is a compact UV laser machine designed for professional mobile device repair and precise engraving. It utilizes a 5W UV laser at a 355nm wavelength, making it suitable for tasks such as phone screen separation, back glass removal, and metal frame separation without damaging internal components. The machine features an automatic focus system, mobile phone connectivity for control, and an integrated activated carbon smoke exhaust system for safe operation.

TBK958ZE UV Laser Machine main unit with a smartphone and laptop in the background.

Figure 1.1: The TBK958ZE UV Laser Machine, a compact unit for mobile device repair.

2. Safety Information

Operating a laser machine requires strict adherence to safety protocols to prevent injury and equipment damage. Read and understand all safety warnings before operating the TBK958ZE.

  • Eye Protection: Always wear appropriate laser safety glasses when the laser is active and the protective enclosure is open or compromised. The UV laser can cause severe eye damage.
  • Skin Protection: Avoid direct exposure of skin to the laser beam.
  • Fume Extraction: Ensure the activated carbon smoke exhaust system is properly installed and functioning during all operations to remove harmful fumes and particles. Operate in a well-ventilated area.
  • Flammable Materials: Do not operate the machine near flammable liquids, gases, or materials. The laser can ignite certain substances.
  • Electrical Safety: Ensure the machine is properly grounded and connected to a stable power source (110-220V). Do not operate with damaged power cords or plugs.
  • Authorized Personnel: Only trained and authorized personnel should operate and maintain the laser machine.
  • Emergency Stop: Familiarize yourself with the location and operation of the emergency stop button.

3. Product Features

The TBK958ZE incorporates several advanced features for efficient and safe mobile device repair:

  • Precision UV Laser Technology: Equipped with a 5W UV laser (355nm wavelength) for precise material removal without damaging sensitive internal components.
  • Automatic Focus System: Features a 4.5cm focus height with automatic focusing, eliminating manual adjustments and ensuring consistent accuracy (0.001mm precision).
  • Mobile Phone Connectivity: Allows wireless control of laser parameters, image transfer, and file management directly from a smartphone.
  • Integrated HD Computer: Provides an alternative control interface with an included wireless keyboard and mouse.
  • High-Speed Performance: Achieves marking speeds up to 7000mm/s for rapid processing.
  • Activated Carbon Smoke Exhaust: Built-in system filters harmful fumes and particles, maintaining air quality and operator safety.
  • Cold Air Cooling System: Prevents overheating during extended operation, ensuring consistent performance.
  • Compact Working Area: A 17x17cm working area optimized for smartphones and small tablets.
Diagram illustrating multiple features of the TBK958ZE, including quick mobile phone drawing, autofocus, activated carbon filtration exhaust, and high power cold light source.

Figure 3.1: Key functional features of the TBK958ZE machine.

Diagram showing the internal airflow of the built-in activated carbon smoke exhaust system within the TBK958ZE machine.

Figure 3.2: Illustration of the activated carbon smoke exhaust system.

4. Components and Packing List

Verify that all components listed below are present in your package upon unboxing.

Image showing the packing list contents: a wooden case, the 958ZE machine, a metal card, a hexagon wrench set, a power cord, and a wireless mouse and keyboard.

Figure 4.1: Contents included in the TBK958ZE package.

  • TBK958ZE UV Laser Machine Unit
  • Power Cord
  • Wireless Keyboard
  • Wireless Mouse
  • Hexagon Wrench Set
  • Metal Card (for calibration or specific functions)
  • User Manual (this document)

5. Setup

  1. Unpacking: Carefully remove the TBK958ZE machine and all accessories from its packaging. Retain the packaging for future transport or storage.
  2. Placement: Place the machine on a stable, level surface in a well-ventilated area, away from direct sunlight and heat sources. Ensure adequate space around the machine for air circulation and operation.
  3. Power Connection: Connect the power cord to the machine's power input and then to a grounded electrical outlet (110-220V).
  4. Peripheral Connection: Connect the wireless keyboard and mouse to the machine's USB ports.
  5. Initial Power On: Press the power button to turn on the machine. The built-in HD computer will boot up.
  6. Software Setup (if applicable): If using mobile phone control, download the dedicated application from the official TBK website or app store. Follow the in-app instructions to pair your smartphone with the machine via Wi-Fi.

6. Operating Instructions

This section outlines the general procedure for operating the TBK958ZE for mobile device repair tasks.

  1. Prepare the Workpiece: Place the mobile device (e.g., smartphone, tablet) securely within the machine's working area (17x17cm). Ensure it is properly aligned for the desired operation (e.g., screen separation, back glass removal).
  2. Select Operation Mode:
    • Via Built-in Computer: Use the wireless keyboard and mouse to navigate the interface on the HD screen. Select the appropriate repair function (e.g., "Remove Phone Screen," "Remove Back Cover").
    • Via Mobile App: Open the paired mobile application. Select the desired operation and transfer any necessary images or parameters wirelessly.
  3. Set Laser Parameters: Adjust laser power, speed, and number of passes as required for the specific material and task. The automatic focus system will adjust the laser height (4.5cm focus height).
  4. Initiate Laser Process: Once parameters are set and the workpiece is secured, initiate the laser process. Ensure the protective enclosure is closed before starting. The activated carbon smoke exhaust system will activate automatically.
  5. Monitor Progress: Observe the laser operation through the protective viewing window. Do not open the enclosure while the laser is active.
  6. Completion: Once the process is complete, the machine will indicate its status. Wait for the laser to fully disengage before opening the enclosure and removing the workpiece.
Image showing the TBK958ZE machine alongside illustrations of a smartphone with its screen removed, back cover removed, and stand dismantled, demonstrating its versatility.

Figure 6.1: Examples of disassembly operations performed by the machine.

Close-up image of the TBK958ZE laser precisely removing the back cover glue from a smartphone.

Figure 6.2: Laser in action removing a phone's back cover.

Video 6.1: Demonstration of the TBK958ZE UV Laser machine in operation, showcasing its capabilities for mobile device repair.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your TBK958ZE machine.

  • Cleaning: Regularly clean the working area and the machine's exterior with a soft, dry cloth. Ensure no debris obstructs the laser path or ventilation openings.
  • Activated Carbon Filter Replacement: The activated carbon filter in the smoke exhaust system will require periodic replacement depending on usage. Refer to the filter's specific instructions for replacement intervals.
  • Lens Cleaning: If the laser output appears weak or inconsistent, the laser lens may need cleaning. Consult a qualified technician or the manufacturer's support for proper lens cleaning procedures to avoid damage.
  • Software Updates: Periodically check for software updates for the built-in computer and mobile application to ensure optimal performance and access to new features.

8. Troubleshooting

This section provides solutions to common issues you might encounter.

Problem Possible Cause Solution
Machine does not power on. Power cord disconnected; power outlet issue. Check power cord connection; test power outlet with another device.
Laser not firing. Protective enclosure open; emergency stop engaged; incorrect parameters. Ensure enclosure is closed; disengage emergency stop; verify laser parameters.
Poor marking quality/inconsistent results. Incorrect focus; dirty lens; unsuitable laser parameters for material. Ensure auto-focus is active; clean laser lens (if trained); adjust laser power/speed.
Smoke exhaust not working effectively. Filter clogged; fan malfunction. Check and replace activated carbon filter; contact support if fan is faulty.
Mobile app not connecting. Wi-Fi issue; app not updated; machine not in pairing mode. Verify Wi-Fi connection; update app; restart machine and app; re-attempt pairing.

9. Specifications

Feature Specification
Model Number 958ZE
Laser Type UV Laser
Laser Power 5W
Wavelength 355nm
Working Area 17 x 17 cm
Focus System Automatic Focus (4.5cm height)
Marking Speed Up to 7000mm/s
Precision Accuracy 0.001mm
Smoke Exhaust Activated Carbon Filtration System
Cooling System Cold Air Cooling
Control Interface Built-in HD Computer, Mobile App Connectivity
Power Input 110-220V Universal
Product Dimensions 9 x 15 x 19 inches
Item Weight 77 pounds
Manufacturer TBK

10. Warranty and Support

The TBK958ZE UV Laser Machine comes with a 30-day easy return policy. For specific warranty details, technical support, or service inquiries, please contact the seller, TBK-us, directly through your purchase platform or the official TBK website. Ensure you have your model number (958ZE) and purchase information available when contacting support.

© 2026 TBK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.