QKVJULBN BP300-S42UN32A Peristaltic Pump Instruction Manual

Model: BP300-S42UN32A

1. Introduction

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your QKVJULBN BP300-S42UN32A Peristaltic Pump. Please read this manual thoroughly before using the pump to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

The QKVJULBN BP300-S42UN32A is a high-precision peristaltic pump designed for accurate dosing and transfer of various liquids, gels, and greases. Its compact size makes it suitable for applications requiring small, controlled flow rates.

2. Safety Information

Always observe the following safety precautions to prevent personal injury or damage to the pump:

  • Ensure the power supply voltage matches the pump's requirements (12V or 24V, as specified for your model).
  • Do not operate the pump with damaged tubing or electrical connections.
  • Avoid contact with moving parts during operation.
  • Do not immerse the pump in liquid.
  • Use only compatible tubing materials for the liquids being transferred.
  • Disconnect power before performing any maintenance or tubing changes.
  • Keep the pump away from excessive heat, moisture, and corrosive environments.

3. Product Overview

The BP300-S42UN32A peristaltic pump consists of a stepper motor, a pump head with rollers, and a transparent cover. The liquid is contained entirely within the tubing, preventing contamination and simplifying cleaning.

Angled view of the QKVJULBN BP300-S42UN32A Peristaltic Pump with two tubes connected.
Figure 3.1: Angled view of the pump. This image shows the overall structure of the peristaltic pump, including the stepper motor on the left, the pump head with its transparent cover, and two tubes connected to the inlet and outlet ports.
Side view of the QKVJULBN BP300-S42UN32A Peristaltic Pump with a single tube connected to the outlet.
Figure 3.2: Side view of the pump. This perspective highlights the compact design of the pump, showing the stepper motor housing and the pump head with a single tube extending from the outlet. A mounting bracket is visible at the bottom.
Front view of the QKVJULBN BP300-S42UN32A Peristaltic Pump with the transparent cover closed.
Figure 3.3: Front view of the pump. This image displays the transparent cover of the pump head, allowing a view of the internal mechanism. The inlet and outlet ports for tubing are visible at the top.

4. Setup

4.1 Unpacking

Carefully remove the pump from its packaging. Inspect for any visible damage. Retain packaging for future transport or storage.

4.2 Mounting

The pump features an integrated mounting bracket. Secure the pump to a stable surface using appropriate fasteners (not included) through the holes in the bracket. Ensure the pump is level and stable to prevent vibration during operation.

4.3 Tubing Installation

  1. Open the transparent cover of the pump head. This may involve unlatching or unscrewing retaining clips.
  2. Carefully insert the appropriate peristaltic tubing into the pump head, ensuring it sits correctly within the rotor path.
  3. Close the transparent cover, ensuring it is securely latched or screwed down. The tubing should be compressed by the rollers.
  4. Connect the inlet tubing to your liquid source and the outlet tubing to your destination. Ensure all connections are secure to prevent leaks.
Top-down view of the QKVJULBN BP300-S42UN32A Peristaltic Pump with the transparent cover open, showing the rotor and tubing path.
Figure 4.1: Pump head with cover open. This image illustrates the internal mechanism of the pump head, with the transparent cover lifted, revealing the rotor and the path where the peristaltic tubing is installed.

4.4 Power Connection

Connect the pump to a compatible 12V or 24V DC power supply (not included) according to the wiring diagram provided with your specific motor controller. Ensure correct polarity to avoid damage.

5. Operating Instructions

5.1 Initial Start-up

  1. Ensure all tubing connections are secure and the pump head cover is properly closed.
  2. Verify that the liquid source is available and the destination is ready to receive the liquid.
  3. Apply power to the pump. The stepper motor will begin to rotate the rollers.

5.2 Flow Control

The flow rate of this peristaltic pump is controlled by the speed of the stepper motor. Adjust the motor speed using your external stepper motor driver/controller (not included) to achieve the desired flow rate. Refer to your motor controller's manual for specific speed adjustment procedures.

5.3 Shutting Down

To stop the pump, remove power from the stepper motor. For extended periods of non-use, disconnect the pump from the power supply and drain any remaining liquid from the tubing.

6. Maintenance

6.1 Tubing Replacement

Peristaltic tubing is a wear item and should be replaced periodically, depending on usage and the type of liquid being pumped. Signs of wear include cracking, hardening, or reduced flow accuracy.

  1. Disconnect power from the pump.
  2. Open the pump head cover.
  3. Remove the old tubing.
  4. Clean the pump head and rollers if necessary (see 6.2).
  5. Install new, compatible tubing as described in Section 4.3.
  6. Close the pump head cover securely.

6.2 Cleaning the Pump Head

Regularly inspect the pump head and rollers for any residue or debris. If cleaning is required:

  • Disconnect power and remove the tubing.
  • Wipe the rollers and the interior of the pump head with a damp cloth. For stubborn residues, use a mild, non-abrasive cleaning solution compatible with the pump head materials.
  • Ensure all parts are completely dry before reinstalling tubing and operating the pump.

7. Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power or incorrect wiring
Motor controller issue
Check power connections and polarity
Verify motor controller functionality
No liquid flowTubing kinked or blocked
Pump head cover not closed properly
Worn tubing
Air in tubing
Inspect and clear tubing
Ensure pump head cover is secure
Replace tubing
Prime the pump by running it until liquid flows
Inconsistent flowWorn tubing
Air bubbles in liquid
Inconsistent motor speed
Replace tubing
Ensure liquid source is free of air
Check motor controller for stable output
Excessive noiseLoose mounting
Worn rollers or bearings
Debris in pump head
Tighten mounting fasteners
Contact support for replacement parts
Clean pump head and rollers

8. Specifications

FeatureDetail
Model NumberBP300-S42UN32A
StructurePeristaltic Pump
MaterialPA66+PC
Flow Rate0-400 ml/min
Lifetime10000H
Motor TypeStepper Motor
Rollers Quantity3
Voltage12V / 24V (depending on specific motor configuration)
Item Weight1.76 ounces
Package Dimensions0.39 x 0.39 x 0.39 inches
CertificationISO9001

9. Warranty and Support

9.1 Warranty Information

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please refer to your purchase documentation for specific warranty terms and duration. The warranty does not cover damage caused by improper installation, misuse, neglect, or unauthorized modifications.

9.2 Customer Support

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your retailer or the manufacturer directly. When contacting support, please have your product model number (BP300-S42UN32A) and purchase date available.