1. Introduction
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your AGTANA 14000 BTU Inverter Portable Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.

Figure 1: AGTANA 14000 BTU Inverter Portable Air Conditioner
The AGTANA portable air conditioner is designed to provide cooling, dehumidification, and fan functions for indoor spaces up to 700 sq. ft. It features inverter technology for energy efficiency and a dual-hose system for enhanced cooling performance.
2. Safety Information
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instructions may cause harm or damage.
General Safety Precautions
- Read all instructions carefully before operating the appliance.
- Always place the unit on a flat, stable, and level surface to prevent tipping.
- Do not block the air inlets or outlets of the unit. Maintain a minimum clearance of 20 inches (50 cm) from walls or other objects.
- Keep children and pets away from the unit during operation.
- Do not insert fingers or foreign objects into the air outlets.
- Unplug the appliance from the power outlet before cleaning, moving, or performing any maintenance.
- Do not operate the unit with a damaged power cord or plug. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- Use only the window kit and accessories provided by the manufacturer.
- Do not use the unit in wet areas such as bathrooms or laundry rooms.
- Ensure the voltage and frequency of the power supply match the specifications on the rating label.
Electrical Safety
- This appliance must be properly grounded.
- Do not connect the unit to a multi-socket adapter or extension cord.
- Do not pull the power cord to disconnect the plug from the outlet. Grasp the plug firmly and pull to remove.
- Do not touch the appliance with wet hands.
3. Package Contents
Verify that all items are included in the package:
- Portable AC Unit (1)
- User Manual (1)
- Window Kit (1)
- Remote Control (1)
4. Product Overview
Key Features
- Inverter & Dual Hose Technology: The inverter compressor adjusts power to maintain temperature, saving energy. The dual-hose design prevents negative pressure, enhancing cooling efficiency.
- 14000 BTU Cooling Capacity: Provides 14,000 BTU (10,000 BTU SACC) for rooms up to 700 sq. ft.
- Wide-Angle Auto-Swing: Features a 3-speed fan with 25-85° auto-swing for even air distribution.
- Quiet Operation: Operates at a low noise level of 42dB, suitable for bedrooms and nurseries.
- 3-in-1 Functionality: Offers Cooling, Fan, and Dehumidifier modes.
- Self-Evaporating System: Recycles condensate to cool internal coils, reducing the need for frequent drainage.
- High Dehumidification: Removes up to 96 pints of moisture per day.
- Dual Control: Features a front LED display, top-mounted button panel, and a backlit remote control (28ft range).
- Easy Mobility: Equipped with 360° heavy-duty wheels and hidden handles for effortless movement.

Figure 2: Key Features of the AGTANA Portable AC
Internal Components
The unit utilizes an inverter compressor and dual-motor system for efficient cooling and quiet operation. The self-evaporating system manages condensate by transferring excess water to the condenser, where it evaporates and is exhausted as vapor.

Figure 3: Internal Components and Cooling Mechanism
5. Setup & Installation
The AGTANA portable air conditioner is designed for quick and easy installation. The included dual-hose window kit is compatible with most horizontal and vertical windows.
Window Kit Installation
Follow these steps to install the window kit:
- Prepare the Window Kit: Assemble the window panel components to fit your window opening. The kit supports single (20.5"), dual (31.5"-38.8"), and triple (40.9"-57.3") configurations.
- Secure Panels: Align the back side slot with the butterfly bolt and fasten the window kit with the provided screws.
- Install in Window: Place the assembled window kit into the window opening and extend it to fit snugly. Close the window to secure the kit.
- Attach Exhaust Hoses: Stretch the exhaust hoses and insert the adapters into the rear of the AC unit.
- Connect to Window Kit: Secure the hose adapters to the openings in the window kit.
- Finalize: Fix the attached small latch to ensure a secure seal.

Figure 4: Window Kit Configurations

Figure 5: Step-by-Step Installation Guide
Installation Video
For a visual guide on the installation process, please refer to the official installation video:
Video 1: AGTANA 14000 BTU Inverter Portable Air Conditioner Installation Guide. This video demonstrates the process of setting up the portable AC unit and its window kit.
6. Operating Instructions
Your AGTANA portable AC offers multiple modes and control options for optimal comfort.
Control Panel and Remote Control
The unit can be controlled via the top-mounted button panel or the included remote control. The front LED display shows current settings.

Figure 6: Dual Control Options (Unit and Remote)
Operating Modes
- Cool Mode: Provides powerful cooling for your room. Set your desired temperature between 61°F and 86°F.
- Fan Mode: Circulates air without cooling. Features 3 fan speeds.
- Dehumidifier Mode: Removes excess moisture from the air, up to 96 pints per day.

Figure 7: 3-in-1 Operating Modes
Additional Functions
- Auto-Swing: Activates the internal louvers to oscillate, distributing air evenly.
- Sleep Mode: Adjusts temperature and fan speed for quiet, comfortable sleep. The unit operates at a whisper-quiet 42dB in this mode.
- Timer: Program the unit to turn on or off automatically within a 24-hour period.
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your portable air conditioner.
Cleaning the Air Filter
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality. A dirty filter can reduce cooling efficiency and airflow.
- Unplug the unit from the power outlet.
- Locate and remove the air filter from the back of the unit.
- Wash the filter under running water (warm, not hot) or use a vacuum cleaner to remove dust.
- Allow the filter to air dry completely before reinstalling. Do not expose to direct sunlight.
- Reinsert the dry filter into the unit.
Drainage
The unit features a self-evaporating system, which typically exhausts most condensate as vapor. However, in high humidity conditions or during prolonged use, the internal water tank may fill, indicated by a 'Full' light on the display. In such cases, manual drainage is required.

Figure 8: Self-Evaporating System
- Unplug the unit.
- Place a shallow pan or tray under the drain port at the bottom rear of the unit.
- Remove the drain plug. Water will begin to flow out.
- Once all water has drained, replace the drain plug securely.
- For continuous drainage (e.g., during dehumidifier mode or in very humid environments), connect a drain hose (not included) to the drain port and direct it to a floor drain or bucket.
Storage
When storing the unit for an extended period:
- Drain all water from the unit.
- Clean the air filter.
- Run the unit in fan-only mode for a few hours to dry the interior.
- Unplug the power cord and wrap it neatly.
- Store the unit in a dry, cool place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
Before contacting customer support, please refer to the following troubleshooting guide for common issues:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply Power cord not plugged in Circuit breaker tripped | Check power outlet Ensure power cord is securely plugged in Reset circuit breaker |
| Unit not cooling effectively | Temperature setting too high Air filter dirty Window kit not properly installed Room size too large Doors/windows open | Lower desired temperature Clean air filter Ensure window kit is sealed Verify room size is within 700 sq. ft. Close all doors and windows |
| Water leakage | Drain plug loose or missing Drain hose improperly connected (if used) | Securely fasten drain plug Ensure drain hose is properly attached and directed |
| Unusual noise or vibration | Unit not on a level surface Obstruction in fan or air vents | Place unit on a flat, level surface Check for and remove any obstructions |
| "Full" indicator light is on | Internal water tank is full | Drain the water from the unit as per maintenance instructions |
9. Specifications
Detailed technical specifications for the AGTANA 14000 BTU Inverter Portable Air Conditioner:

Figure 9: Product Specifications
| Feature | Detail |
|---|---|
| Brand | AGTANA |
| Model Name | KY-V10K/11D |
| Model Number | AGPAC-10BP-C1 |
| Cooling Power (ASHRAE) | 14000 BTU |
| Cooling Power (SACC/DOE) | 10000 BTU |
| Power Supply | 115V~, 60Hz |
| Wattage | 1200 watts |
| Fan Speed | 3 levels |
| Dry Capacity | 96 Pints/Day |
| Working Temperature Range | 61°F - 90°F |
| Max Air Flow | 430 m³/h |
| Noise Level | 42 dB |
| Product Dimensions (D x W x H) | 15" x 12" x 26" |
| Item Weight | 50 lbs |
| Refrigerant | R-32 |
| Floor Area Coverage | Up to 700 sq. ft. |
| Control Method | Remote, Touch |
| Special Features | Dehumidifier, Fast Cooling, Inverter Compressor, Remote Controlled, Sleep Mode |
10. Warranty & Support
Manufacturer's Warranty
The AGTANA 14000 BTU Inverter Portable Air Conditioner comes with a 1-year manufacturer's limited warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
Customer Support
For any inquiries, technical assistance, or warranty claims, please contact AGTANA customer support. Our dedicated and professional service team is available to assist you.