1. Introduction
Thank you for choosing the BODEGA UL-S1200N-ST Commercial Upright Freezer. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new appliance. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Information
To reduce the risk of fire, electric shock, or injury, always follow basic safety precautions:
- Ensure the unit is properly grounded.
- Do not operate the unit with a damaged power cord or plug.
- Keep ventilation openings clear of obstructions.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Only qualified personnel should perform repairs.
- Unplug the unit before cleaning or performing maintenance.
3. Product Overview
3.1 Dimensions and Capacity
The BODEGA UL-S1200N-ST is a 54-inch wide commercial upright freezer designed for high-volume storage. Its external dimensions are approximately 54.02 inches (W) x 33.94 inches (D) x 80.94 inches (H). The internal capacity is 42.06 cubic feet (1386L).

Figure 1: External Dimensions and Capacity Overview
3.2 Key Features
- Precision Temperature Control: Digital display with a temperature range of -10°F to 10°F (-23℃ to -12℃). Fan-assisted airflow ensures uniform cooling.
- Automatic Defrost: Minimizes ice buildup for consistent performance.
- Durable Construction: Heavy-duty stainless steel exterior and white aluminum interior, designed for commercial use. High-density foam insulation for thermal retention.
- Adjustable Shelving: Includes 6 adjustable heavy-duty metal shelves, each supporting up to 60 kg, allowing flexible height customization.
- User-Friendly Doors: Self-closing doors (when opened less than 90°) and a stay-open feature (when opened beyond 90°) for convenience.
- Mobility and Security: Four lockable casters for easy movement and secure placement. Equipped with door locks.
- Internal Lighting: LED light strips on both sides provide clear illumination.

Figure 2: High-Quality Material Construction

Figure 3: Low-Temperature Storage for Freshness

Figure 4: Energy Efficiency

Figure 5: User-Friendly Automatic Rebound Door

Figure 6: 6-Tier Adjustable Shelves for Organized Storage

Figure 7: User-Friendly Design Details
4. Setup
4.1 Unpacking and Placement
Upon receiving your freezer, carefully unpack it. Ensure all packaging materials are removed. Place the unit on a flat, stable surface. Allow adequate clearance around the unit for proper ventilation (at least 6 inches from walls). After transport, allow the freezer to remain in an upright position for several hours (approximately 24 hours) before connecting it to power. This allows the refrigerant and oil in the cooling system to settle.
4.2 Shelf Installation
The freezer comes with adjustable shelves. To install or adjust shelves:
- Remove any existing shelves.
- Install the K-clips into the desired slots on the interior side rails, ensuring all four clips for a single shelf are at the same height.
- Carefully place the shelf onto the K-clips, ensuring it sits securely and level.
- Arrange shelves according to the dimensions of the items you intend to store.
Video 1: How to Use BODEGA Commercial Freezer More Efficiently? This video demonstrates the installation of shelves and initial setup procedures.
4.3 Initial Power-On
After the recommended settling period, plug the freezer into a dedicated 115V AC, 60Hz power outlet. The unit is equipped with a US standard 3-prong plug. Allow the unit to preheat for one hour before placing any items inside.
5. Operating Instructions
5.1 Control Panel
The control panel is located at the top of the unit and features a digital temperature display, a power switch, and temperature adjustment buttons.
5.2 Temperature Adjustment
To adjust the temperature:
- Manually turn on the power switch.
- Press and hold the 'SET' button for 2 seconds until the temperature display starts flashing.
- Use the '▲' (up) and '▼' (down) keys to set the desired temperature. Hold the button down for rapid scrolling.
- The adjustable temperature range is -10°F to 10°F (-23℃ to -12℃).
- Press 'SET' again or wait a few seconds for the new setting to be saved.
5.3 Defrost Function
The freezer features an automatic defrost function. For manual defrost:
- Press and hold the defrost button (snowflake icon) for 2 seconds.
- The defrost icon will remain continuously lit until the defrosting process is complete.
5.4 Child Lock
To lock or unlock the control panel and prevent accidental operation, press and hold the '▲' (up) and '▼' (down) buttons simultaneously for 3 seconds.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your freezer.
6.1 Cleaning
Always disconnect the power supply before cleaning. Remove all items from the freezer.
- Interior: Wipe down the interior with a dry or damp cloth. Use mild soap and water if necessary. Do not use abrasive cleaners, strong cleaners, or sharp/pointed objects, as these may damage the equipment.
- Exterior: Clean the stainless steel exterior with a soft cloth and a non-abrasive stainless steel cleaner. The fingerprint-resistant stainless steel can be wiped clean easily.
- Condenser Coils: Periodically clean the condenser coils located at the bottom of the unit to ensure efficient cooling. Use a brush or vacuum cleaner to remove dust and debris.
Video 2: BODEGA 54" W Commercial Freezer Upright. This video provides a visual overview of the freezer's features and maintenance.
6.2 Gasket Maintenance
Inspect door gaskets regularly for cracks or tears. Clean gaskets with mild soap and water to maintain a tight seal, which is crucial for energy efficiency.
7. Troubleshooting
Before contacting customer support, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Freezer not cooling | Power supply issue; thermostat set too high; condenser coils dirty; door not closed properly. | Check power connection; adjust thermostat; clean condenser coils; ensure door is sealed. |
| Excessive noise | Unit not level; fan obstruction; loose components. | Level the unit; check for fan obstructions; tighten any loose parts. |
| Door not sealing | Gasket dirty or damaged; unit not level. | Clean or replace gasket; level the unit. |
8. Specifications
| Feature | Detail |
|---|---|
| Model Number | UL-S1200N-ST |
| Product Dimensions (D x W x H) | 33.94" x 54.02" x 80.94" |
| Capacity | 42.06 Cu.Ft (1386L) |
| Temperature Range | -10°F to 10°F (-23℃ to -12℃) |
| Color | Stainless Steel |
| Door Material Type | Stainless Steel |
| Door Orientation | Double Swing |
| Installation Type | Freestanding |
| Shelves | 6 Adjustable Heavy-Duty Metal Shelves |
| Power Supply | 115V AC, 60Hz |
| Manufacturer | BODEGA |
9. Warranty and Support
This BODEGA commercial freezer comes with a 1-year warranty period. For specific warranty details, please refer to the warranty card included with your product or contact customer support. BODEGA is committed to providing reliable cooling solutions and offers professional customer service.
If you have any questions or require assistance, please contact BODEGA customer support. Contact information can typically be found on the product packaging or the official BODEGA website.