Stondon Blood Glucose Monitor Kit G-520 User Manual

Model: G-520

1. Introduction

This manual provides instructions for the proper use and care of your Stondon Blood Glucose Monitor Kit. This kit is designed for self-testing blood glucose levels at home. It offers quick, accurate results to assist in managing blood sugar.

The Stondon Blood Glucose Monitor Kit includes a blood glucose meter, lancing device, test strips, and lancets. It is designed for ease of use, providing results in approximately 5 seconds without requiring manual coding.

Stondon Blood Glucose Monitor Kit contents

Image: Overview of the Stondon Blood Glucose Monitor Kit components.

2. What's in the Box

Your Stondon Blood Glucose Monitor Kit typically includes the following items:

  • Blood Glucose Monitor (Meter)
  • Lancing Device
  • 50 Test Strips (in vials)
  • 50 Lancets
  • Carrying Case
  • User Manual
Stondon Blood Glucose Monitor Kit with carrying case

Image: All components of the Stondon Blood Glucose Monitor Kit, including the carrying case.

3. Setup

3.1 Meter Settings

To set the time and unit (mg/dL or mmol/L) on your monitor:

  1. Ensure the meter is off.
  2. Press and hold the 'M' button to enter the setting mode.
  3. Follow the on-screen prompts to adjust the time and select your preferred unit of measurement.
Stondon Blood Glucose Monitor showing mg/dL and mmol/L settings

Image: The blood glucose monitor displaying options for mg/dL and mmol/L units.

3.2 Lancing Device Preparation

Prepare the lancing device for blood sample collection:

  1. Rotate and remove the cap from the lancing device.
  2. Insert a new sterile lancet firmly into the lancet holder.
  3. Twist off the protective cap from the lancet.
  4. Replace the lancing device cap.
  5. Adjust the penetration depth by rotating the top of the lancing device. There are 5 depth levels; start with a lower setting and adjust as needed for a sufficient blood sample.
  6. Pull back the cocking control until it clicks, indicating it is ready to use.
Stondon Lancing Device preparation steps

Image: Detailed steps for preparing the lancing device, including removing the cap, inserting a lancet, and adjusting depth levels.

3.3 Test Strip Insertion

The monitor automatically recognizes batch codes, eliminating the need for manual coding.

  • Remove a test strip from its vial and immediately close the vial cap tightly to protect remaining strips from moisture.
  • Insert the test strip into the test strip port of the meter. The meter will turn on automatically.
Stondon Test Strip and Lancets

Image: Illustration of the test strip and lancets, highlighting the absorbent hole and induction area for the test strip.

4. Operating Instructions: Blood Glucose Testing Procedure

Follow these steps for an accurate blood glucose test:

  1. Wash and Dry Hands: Thoroughly wash your hands with soap and warm water, then dry them completely.
  2. Assemble Lancing Device: Prepare the lancing device as described in Section 3.2.
  3. Prepare Test Strip: Remove a test strip from the vial and close the cap. Insert the test strip into the meter.
  4. Obtain Blood Sample: Place the lancing device firmly against the side of your fingertip and press the release button. A small drop of blood will form.
  5. Apply Blood Sample: Gently touch the absorbent hole of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip.
  6. Read Results: The meter will display your blood glucose result in approximately 5 seconds.
  7. Eject Strip and Lancet: Use the single-touch strip ejection feature to hygienically remove the used test strip. Eject the used lancet from the lancing device into a suitable sharps container.
8 Simple steps for blood glucose testing

Image: Visual guide illustrating the 8 simple steps for performing a blood glucose test.

4.1 Video Demonstration

Video: A demonstration showing the ease of use and components of the Stondon Blood Glucose Monitor Kit, including strips and lancets.

5. Getting Accurate Test Results

To ensure the most accurate readings:

  • Before Use:
    • Check test strips for contamination, dampness, or expiration.
    • Clean and dry your hands thoroughly to avoid contaminating the blood sample.
  • During Use:
    • Before collecting a blood sample, massage your fingers for 10 seconds and lower your arm for 5 seconds to ensure adequate blood flow.
    • Avoid touching the contact strips and the absorption hole of the test strip with your fingers, except for the blood collection site.
  • Important Note: Never reuse a test strip. Continuous testing may show slight variations as each drop of blood can differ, potentially leading to minor differences in test results.
Tips for accurate blood glucose test results

Image: Guidelines for achieving accurate blood glucose test results, including pre-test and during-test considerations.

6. Memory Function

The Stondon Blood Glucose Monitor automatically stores up to 500 test results.

  • To view the most recent test result, short press the 'M' button when the device is off. The result will display for 1 second.
  • To view subsequent test results, short press the 'M' button again to scroll through the stored readings.
Stondon Blood Glucose Monitor memory function

Image: Illustration of the monitor's memory function, showing how to access stored blood glucose readings.

7. Maintenance

7.1 Cleaning the Meter

Wipe the meter's exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents.

7.2 Storage

  • Store the meter, test strips, and lancing device in their original carrying case in a cool, dry place.
  • Keep test strip vials tightly closed when not in use to prevent moisture exposure.
  • Do not store in direct sunlight or extreme temperatures.

8. Troubleshooting

If you encounter issues with your Stondon Blood Glucose Monitor, refer to the following common problems and solutions:

  • Error Message Displayed: Refer to the specific error codes in the full user manual for detailed explanations and corrective actions. Ensure test strips are not expired and are inserted correctly.
  • Inconsistent Readings: Ensure proper hand hygiene, sufficient blood sample size, and correct application of blood to the test strip. Check that test strips are stored correctly and not expired.
  • Meter Not Turning On: Check the battery. Replace if necessary.
  • No Blood Sample: Adjust the lancing device depth setting to a higher number. Ensure the lancing device is properly cocked before use.

If problems persist, contact customer support.

9. Specifications

Feature Detail
Package Dimensions 4.72 x 3.54 x 2.01 inches
Item Weight 4.6 ounces
Brand Stondon
Battery Cell Composition Alkaline
Included Components Test Strips 100 (Note: Kit includes 50 test strips and 50 lancets as per product description)

10. Important Safety Information

This device is intended for monitoring diabetes mellitus. Always consult with a healthcare professional for diagnosis, treatment, and any questions regarding your blood glucose levels or diabetes management.

  • Do not use expired test strips or lancets.
  • Keep out of reach of children.
  • Dispose of used lancets and test strips properly in a sharps container.
  • Do not make any medical decisions without consulting your doctor.

11. Warranty and Support

For warranty information, technical support, or to purchase replacement supplies, please refer to the contact information provided with your product packaging or visit the official Stondon website.

© 2026 Stondon. All rights reserved.

Related Documents - G-520

Preview G-520 Blood Glucose Meter User Manual: Setup, Testing & Care
This user manual provides comprehensive instructions for the G-520 Blood Glucose Meter, covering setup, testing procedures, safety guidelines, and maintenance for accurate home blood glucose monitoring.
Preview Glucoracy G-425-2 Blood Glucose Monitoring System Quick Start User Guide
A quick start guide for the Glucoracy G-425-2 Blood Glucose Monitoring System, detailing the steps for testing blood glucose levels, including before and after test procedures, and important warnings.
Preview Glucoracy G-425-2 Blood Glucose Monitoring System User Manual
Comprehensive user manual for the Glucoracy G-425-2 Blood Glucose Monitoring System. Learn how to use the meter, test strips, and lancing device for accurate blood glucose measurement at home. Includes safety instructions, limitations, setup, testing procedures, cleaning, and troubleshooting.
Preview Glucoracy G-425-2 Blood Glucose Monitoring System User Manual
Comprehensive user manual for the Glucoracy G-425-2 Blood Glucose Monitoring System. Learn how to use, care for, and troubleshoot your blood glucose meter for accurate home testing.
Preview LinkSun G-425-3 Blood Glucose Monitoring System User Manual
Comprehensive user manual for the LinkSun G-425-3 Blood Glucose Monitoring System, detailing setup, testing procedures, safety precautions, and troubleshooting for accurate blood glucose measurement.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.