1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your FOTING 1.6HP Shallow Well Pump with Pressure Tank. Please read all instructions carefully before use to ensure proper function and to prevent injury or damage.

Figure 1: FOTING 1.6HP Shallow Well Pump with Pressure Tank. This image shows the complete pump unit, highlighting its compact design and blue and grey color scheme.
2. Safety Information
Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury. This pump is designed for water transfer only. Do not use with flammable or corrosive liquids.
- Electrical Safety: Ensure the power supply matches the pump's voltage (115 Volts). Always connect to a grounded outlet. Do not operate with damaged cords or plugs.
- Overheat Protection: The pump is equipped with overheat protection to prevent motor burnout. If the pump stops unexpectedly, allow it to cool before restarting.
- Water Leakage: The durable carbon ceramic mechanical seal helps prevent water leakage. Regularly inspect for any signs of leaks.
- Priming: The pump requires priming with water before its first use to ensure proper operation and prevent damage.
- Check Valve: A check valve must be installed at the inlet pipe to maintain prime and prevent backflow.
3. Product Features
The FOTING 1.6HP Shallow Well Pump is engineered for efficient water boosting and irrigation applications.
- Powerful Motor: Features a 1.6HP motor with a durable impeller, providing a maximum flow rate of 1700 GPH and a maximum lift of 180 feet.
- Strong Suction: Capable of suctioning water from depths up to 26 feet.
- Integrated Pressure Tank: Includes a 5-gallon pressure tank with a pre-set pressure switch (starts at 1.5 bar, shuts off at 3 bar) for automatic operation and consistent water pressure.
- Pressure Gauge: A well-assembled pressure gauge allows for timely observation of water pressure.
- Durable Construction: Constructed with reinforced thermoplastic and a finely finished iron tank for corrosion and wear resistance.
- Overheat Protection: Equipped with a safety mechanism to prevent motor damage from overheating.
- Easy Connection: Features 1-inch NPT outlet and inlet for straightforward pipe hook-up.
- Portable Design: Includes a convenient handle for easy transportation.

Figure 2: Product Details. This image highlights key components such as the 1" NPT Outlet, 1" NPT Intake, High Pressure Soft Tube, Pressure Gauge, 6-Gal Pressure Tank, and Stable Base.

Figure 3: Key Features. This image illustrates the portable handle for easy transport, the cleanable filter basket for impurity removal, and the safety switch to prevent accidental startup.
4. Setup and Installation
Proper installation is crucial for the pump's performance and longevity.
- Placement: Position the pump on a stable, level surface. Ensure it is protected from direct weather exposure and freezing temperatures.
- Inlet Connection: Connect the suction pipe to the 1" NPT inlet. Install a check valve at the inlet to prevent water from flowing back into the well or source.
- Outlet Connection: Connect the discharge pipe to the 1" NPT outlet. Ensure all connections are tight to prevent leaks.
- Priming the Pump: Before first use, remove the priming plug (usually located on top of the pump housing) and fill the pump casing completely with water. Replace the plug securely. This step is critical for shallow well pumps.
- Electrical Connection: Connect the pump to a grounded 115V / 60Hz power outlet.
Video 1: Priming the FOTING Shallow Well Pump. This video demonstrates the essential step of filling the pump with water before its initial operation to ensure proper function.

Figure 4: Working Performance. This diagram shows the maximum suction height of 26 feet and the maximum lift height of 180 feet, along with flow rates at various heights.
5. Operating Instructions
Once installed and primed, the pump operates automatically.
- Initial Start-up: After priming, turn on the power. The pump will start and build pressure in the tank.
- Automatic Operation: The integrated pressure switch will automatically start the pump when pressure drops to 1.5 bar and shut it off when pressure reaches 3 bar, maintaining consistent water supply.
- Monitoring: Observe the pressure gauge to ensure the system is operating within the expected pressure range.
- Applications: This pump is suitable for various uses including garden irrigation, domestic water supply, farm irrigation, and general water transfer.

Figure 5: Wide Applicability. This image displays the pump's use cases, including garden watering, farm irrigation, and water transfer tasks.
6. Maintenance
Regular maintenance ensures optimal performance and extends the pump's lifespan.
- Filter Basket: If your setup includes an external filter basket, regularly clean it to remove coarse impurities and prevent clogging.
- Leak Inspection: Periodically check all connections and the pump body for any signs of water leakage. Tighten connections as needed.
- Winterization: In areas subject to freezing temperatures, drain the pump and associated piping completely to prevent damage from ice expansion.
- Storage: If storing the pump for an extended period, ensure it is clean, dry, and stored in a protected environment.
7. Troubleshooting
Refer to this section for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; Overheat protection activated; Faulty switch | Check power connection; Allow pump to cool; Inspect switch. |
| Pump runs but no water flow | Pump not primed; Suction line air leak; Inlet clogged; Water source depleted | Prime the pump; Check suction line for leaks; Clean inlet; Verify water source. |
| Low water pressure | Partial clog; Air in system; Pressure tank issue; Worn impeller | Check for clogs; Bleed air from system; Inspect pressure tank; Contact support for impeller replacement. |
| Pump cycles too frequently | System leak; Pressure tank air charge low; Faulty pressure switch | Check for leaks in plumbing; Recharge pressure tank air; Replace pressure switch. |

Figure 6: Protection Indicators. This image shows the indicator lights for ON, Power, Pump, and Failure, which can assist in diagnosing operational issues.
8. Specifications
Technical specifications for the FOTING 1.6HP Shallow Well Pump.
| Specification | Value |
|---|---|
| Brand | FOTING |
| Model Number | JGP130062C |
| Motor Power | 1.6 HP |
| Voltage | 115 Volts |
| Frequency | 60 Hz |
| Max Flow Rate | 1700 GPH |
| Max Lifting Height | 180 Feet |
| Max Suction Height | 26 Feet |
| Pressure Tank Capacity | 5 Gallons |
| Automatic Pressure Switch Range | Starts at 1.5 bar, Shuts off at 3 bar |
| Max Fluid Temperature | 95°F (35°C) |
| Inlet/Outlet Size | 1" NPT |
| Material | Plastic, Metal (Reinforced thermoplastic structure, iron tank) |
| Product Dimensions (L x W x H) | 17" x 10.5" x 20" |
9. Warranty and Support
FOTING is committed to providing quality products and customer satisfaction.
- Warranty: The product is designed for reliable performance, with an expected lifespan of 3 years under normal operating conditions. Please refer to your purchase documentation for specific warranty terms and conditions.
- Customer Support: For technical assistance, troubleshooting, or any questions regarding your FOTING pump, please contact FOTING customer service. Professional technical support is available to ensure your water system remains stable.