1. Introduction
Thank you for choosing the Elitech LDM-50D Laser Measure and MOT-270W Moisture Meter bundle. This comprehensive instruction manual provides detailed guidance on the safe and effective use of both devices. The LDM-50D offers precise distance, area, and volume measurements, while the MOT-270W accurately detects moisture levels in wood and building materials. Together, these tools enhance accuracy and efficiency for various home improvement, construction, and woodworking projects.
2. Safety Information
Please read and understand all safety instructions before operating these devices. Failure to follow these instructions may result in laser radiation exposure, electric shock, fire, or serious injury.
2.1 General Safety Precautions
- Keep the devices away from children and unauthorized personnel.
- Do not operate the devices in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Store the devices in a dry, cool place when not in use.
- Do not attempt to modify or disassemble the devices. Repairs should only be performed by qualified service personnel.
- Use only specified batteries. Remove batteries if the device will not be used for an extended period.
2.2 Laser Safety (LDM-50D)
The Elitech LDM-50D is a Class 2 laser product. Observe the following precautions:
- Do not stare directly into the laser beam.
- Do not aim the laser beam at people or animals.
- Avoid direct eye exposure to the laser beam.
- Do not use optical instruments (e.g., binoculars, telescopes) to view the laser beam.
- Ensure the laser is not accidentally activated.
2.3 Moisture Meter Safety (MOT-270W)
- The probes are sharp. Handle with care to avoid injury.
- Do not use the moisture meter on live electrical circuits or materials.
- Keep the probe cover on when not in use to protect the probes and prevent injury.
3. LDM-50D Laser Measure Overview
The Elitech LDM-50D is a compact and precise laser distance meter designed for quick and accurate measurements.
3.1 Key Features
- Measurement Range: Up to 165 feet (50 meters)
- Accuracy: ±2mm (±1/16 inch)
- Measurement Functions: Single, Continuous, Area, Volume, Pythagorean (indirect)
- Display: Backlit LCD
- Data Storage: 99 measurements
- Durability: Dustproof & Drop-Resistant (IP54, 1m drop)
- Additional: Dual bubble levels for stability, Key sound feedback
3.2 Device Layout



4. MOT-270W Moisture Meter Overview
The Elitech MOT-270W is a pin-type moisture meter designed for quick and accurate moisture content detection in various materials.
4.1 Key Features
- Measurement Principle: Electrical Resistance
- Accuracy: ±2% (Wood gear)
- Material Modes: 4 selectable wood types + building materials
- Functions: HOLD, Max/Min value tracking, Automatic calibration
- Display: Large anti-parallax display
- Power: Automatic shutdown after 10 minutes of inactivity
- Additional: Protective probe cover, Battery alert
4.2 Device Layout



5. Setup
5.1 LDM-50D Laser Measure Battery Installation
- Locate the battery compartment cover on the back of the device.
- Slide the cover open.
- Insert two AAA batteries (not included) according to the polarity markings (+/-).
- Close the battery compartment cover securely.
5.2 MOT-270W Moisture Meter Battery Installation and Probe Preparation
- Locate the battery compartment cover on the back of the device.
- Slide the cover open.
- Insert two AAA batteries (not included) according to the polarity markings (+/-).
- Close the battery compartment cover securely.
- Remove the protective probe cover before use. Replace it after each use to prevent damage and ensure safety.
6. Operating Instructions: LDM-50D Laser Measure
6.1 Power On/Off
- To power on: Press the READ button. The laser will activate.
- To power off: Press and hold the OFF/CLEAR button for a few seconds. The device will also auto-power off after 180 seconds of inactivity.
6.2 Unit Selection
Press the UNIT button to cycle through measurement units: meters (m), feet (ft), and inches (in).
6.3 Measurement Reference Point
Press the Reference button to switch the measurement reference point between the front edge and the rear edge of the device. An icon on the display will indicate the current reference point.
6.4 Single Distance Measurement
- Point the laser at the target.
- Press the READ button once to activate the laser.
- Press the READ button again to take the measurement. The result will be displayed.
6.5 Continuous Measurement (Tracking)
- Press the Function button until the continuous measurement icon appears.
- Press the READ button. The device will continuously measure and display the current distance, as well as the maximum and minimum distances detected during the session.
- Press READ again or OFF/CLEAR to stop continuous measurement.
6.6 Area Measurement
- Press the Function button until the area measurement icon appears.
- Measure the first side (e.g., length) by pressing READ.
- Measure the second side (e.g., width) by pressing READ. The device will automatically calculate and display the area.
6.7 Volume Measurement
- Press the Function button until the volume measurement icon appears.
- Measure the length, width, and height sequentially by pressing READ after each measurement. The device will automatically calculate and display the volume.
6.8 Pythagorean Measurement (Indirect Measurement)
This function allows indirect measurement of height or distance using the Pythagorean theorem.
- Press the Function button until the desired Pythagorean measurement icon appears (e.g., for height from two measurements, or height from three measurements).
- Follow the on-screen prompts to take the required measurements (e.g., hypotenuse, base). Ensure the device is held stable and level for accurate results.
- The calculated indirect measurement will be displayed.
6.9 Data Storage and Recall
The LDM-50D can store up to 99 measurements.
- Measurements are automatically saved.
- Press the Memory button to enter memory mode. Use the arrow buttons (if available, or repeated presses of Memory/Function) to scroll through stored data.
- Press OFF/CLEAR to exit memory mode.
7. Operating Instructions: MOT-270W Moisture Meter
7.1 Power On/Off
- To power on: Press the Power button.
- To power off: Press and hold the Power button. The device will also auto-power off after 10 minutes of inactivity.
7.2 Material Selection
The MOT-270W has different modes for various materials to ensure accurate readings.
- Press the M (Mode) button to cycle through the material groups (e.g., Wood Group A, B, C, D, Building Materials). Refer to the device's internal guide or a separate material chart for specific wood types corresponding to each group.
- Select the appropriate group for the material you are testing.
7.3 Taking a Measurement
- Ensure the correct material group is selected.
- Carefully push the two measurement probes into the material surface. Ensure both probes penetrate the material for a stable reading.
- The moisture content percentage will be displayed on the screen.
- Remove the probes from the material.
7.4 HOLD Function
Press the HOLD button to freeze the current reading on the display. Press HOLD again to release it and resume live readings.
7.5 Max/Min Value Tracking
The MOT-270W can track the maximum and minimum moisture values detected during a measurement session.
- While taking measurements, press the SET button to cycle through normal reading, MAX, and MIN display modes.
- In MAX mode, the highest moisture reading recorded will be shown. In MIN mode, the lowest reading will be shown.
7.6 Automatic Calibration
The MOT-270W features automatic calibration for reliable readings. To perform a quick check:
- Ensure the probes are not touching any material.
- Power on the device. It should display a low, stable reading (e.g., 0.0%). If not, ensure the probes are clean and undamaged.
8. Maintenance
8.1 Cleaning
- Wipe the device surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- For the MOT-270W, ensure the probes are clean and free of debris after each use.
8.2 Battery Replacement
- When the low battery indicator appears on the display, replace the batteries promptly.
- Refer to the "Setup" section for battery installation instructions.
- Dispose of old batteries according to local regulations.
8.3 Storage
- Store both devices in a dry, cool environment, away from direct sunlight and extreme temperatures.
- For the MOT-270W, always replace the protective probe cover before storage.
- If storing for an extended period, remove the batteries from both devices to prevent leakage.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| LDM-50D: Device does not power on. | Dead or incorrectly installed batteries. | Replace batteries, ensuring correct polarity. |
| LDM-50D: Inaccurate or inconsistent readings. | Unstable measurement, obstructed laser, incorrect reference point, reflective surface. | Ensure stable positioning, clear laser path, verify reference point, use a target plate for reflective surfaces. |
| LDM-50D: "Error" message on display. | Measurement out of range, strong interference. | Measure within specified range, avoid strong light sources or electromagnetic interference. |
| MOT-270W: Device does not power on. | Dead or incorrectly installed batteries. | Replace batteries, ensuring correct polarity. |
| MOT-270W: Inconsistent or zero readings. | Probes not fully inserted, damaged probes, incorrect material mode, probes touching metal. | Ensure probes are fully inserted, check probes for damage, select correct material mode, avoid metal objects. |
| MOT-270W: Display shows "Lo" or "Hi". | Moisture content is outside the measurable range. | The material is either extremely dry or extremely wet, beyond the device's limits. |
10. Specifications
10.1 Elitech LDM-50D Laser Measure
| Parameter | Value |
|---|---|
| Measurement Range | 0.05m - 50m (0.16ft - 165ft) |
| Measurement Accuracy | ±2mm (±1/16 inch) |
| Measurement Units | m / ft / in |
| Laser Class | Class 2, < 1mW |
| Laser Type | 635nm |
| Data Storage | 99 groups |
| Auto Laser Off | 30 seconds |
| Auto Instrument Off | 180 seconds |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Power Supply | 2 x AAA batteries (1.5V) |
| Dimensions | (Refer to product for exact dimensions, typically compact) |
| Weight | (Refer to product for exact weight, typically lightweight) |
10.2 Elitech MOT-270W Moisture Meter
| Parameter | Value |
|---|---|
| Measurement Principle | Electrical Resistance |
| Measurement Accuracy | ±2% (Wood gear) |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Operating Humidity | 20%RH to 90%RH |
| Auto Instrument Off | 10 minutes |
| Power Supply | 2 x AAA batteries (1.5V) |
| Material Groups | 4 Wood Groups + Building Materials |
11. Warranty and Support
11.1 Warranty Information
Elitech products are designed and manufactured to high-quality standards. For detailed warranty information, including coverage period and terms, please refer to the warranty card included with your product or visit the official Elitech website. Keep your purchase receipt as proof of purchase for warranty claims.
11.2 Customer Support
If you encounter any issues or have questions regarding the Elitech LDM-50D Laser Measure or MOT-270W Moisture Meter, please contact Elitech customer support. You can typically find contact information (phone, email, or support portal) on the official Elitech website or in the product packaging.
For further assistance, visit the Elitech Store on Amazon.