Introduction

The Temtop M100 2nd Gen Air Quality Monitor is designed to provide real-time tracking of indoor air quality. This device monitors 7 key metrics: PM2.5, PM10, CO2, TVOC, Temperature, Humidity, and AQI. It features a 7-inch touchscreen display, WiFi connectivity for app integration, and supports multi-room monitoring with optional sub-monitors.

This manual provides essential information for setting up, operating, and maintaining your air quality monitor to ensure accurate readings and optimal performance.

Package Contents

Temtop M100 2nd Gen Air Quality Monitor and accessories in box
The Temtop M100 2nd Gen Air Quality Monitor, including the main unit, user manual, and charging accessories.

Setup

1. Initial Power-On

Connect the provided USB cable to the monitor and a power adapter. Plug the adapter into a power outlet. The device will automatically power on. For portable use, the built-in lithium-ion battery provides 4+ hours of operation when unplugged.

2. App Download and Device Pairing

To utilize the full features of the monitor, download the "Temtop" app on your smartphone.

Enable Bluetooth permissions for the Temtop app. Open the app, tap the "+" icon in the upper right corner, and follow the in-app prompts to locate and connect your device. The device's GUID QR code can be found on the bottom of the unit for easy scanning. Ensure your Wi-Fi network is 2.4GHz for successful connection.

Temtop app download and setup steps
Visual guide for downloading the Temtop app and connecting the monitor via Bluetooth and Wi-Fi.
This video demonstrates the initial setup and touch screen operation of the Temtop M100 2nd Gen Air Quality Monitor, including power-on, app connection, and basic navigation.

Operating Instructions

1. 7-Inch HD Touchscreen Display

The monitor features a large, intuitive 7-inch HD touchscreen. All key air quality metrics (PM2.5, PM10, CO2, TVOC, Temperature, Humidity, and AQI) are displayed in real-time. The display also shows trend graphs and weather forecasts at a glance. You can adjust brightness and themes via settings.

Temtop M100 2nd Gen Air Quality Monitor with touchscreen display
The 7-inch touchscreen display showing real-time air quality data and health advice.

2. Real-Time Monitoring and Alerts

The device provides continuous real-time monitoring. You can set personalized thresholds for any pollutant through the app. Instant phone notifications will be sent when levels change, allowing you to stay informed immediately. The device also features a dual alert system with mobile app notifications and on-device alerts.

Temtop M100 2nd Gen Air Quality Monitor showing smart alerts and quiet comfort features
The monitor's smart alert system and "Do Not Disturb" mode for quiet monitoring during rest.

3. Data Trends and Insights

Access daily and monthly trend charts via the app to gain a deeper understanding of your air composition and identify patterns. This helps in making informed decisions about your indoor environment.

User viewing air quality trend charts on smartphone app
A user reviewing historical air quality data and trends on the Temtop mobile application.
This video provides an overview of the Temtop M100 2nd Gen's multi-functional capabilities and its role in home air quality monitoring.

Multi-Room Monitoring System

The M100 2nd Gen monitor can be expanded into a multi-room monitoring system. Connect multiple P1 & P2 sub-monitors (sold separately) via LoRa technology to track air quality in various rooms throughout your house from the single app interface.

Diagram showing multi-room air quality monitoring with main unit and sub-monitors
An illustration of how the Temtop M100 2nd Gen monitor can connect with up to 10 sub-devices for whole-home air quality coverage.

App Features & Connectivity

The Temtop app provides a comprehensive interface for managing your air quality data. Key features include:

This video demonstrates the features and interface of the Temtop air quality monitor application, including real-time data, historical trends, and settings.

Maintenance

1. Calibration

For optimal accuracy, periodic calibration of the sensors may be required. The device allows for calibration of PM2.5, CO2, temperature, and humidity. Refer to the device settings or the app for specific calibration procedures. Ensure the device is in a stable, well-ventilated area during calibration for accurate results.

This video demonstrates how to access and perform calibration for various parameters like PM2.5, CO2, temperature, and humidity on the Temtop M100 2nd Gen monitor.

2. Cleaning

Gently wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Keep the sensor vents clear of dust and debris to ensure proper airflow and accurate readings.

Troubleshooting

Specifications

BrandTemtop
Model NumberM100 2nd
Power SourceBattery Powered (1 Lithium Ion battery included)
Product Dimensions5.51"D x 7.17"W x 2.76"H
Item Weight0.44 Pounds (7 ounces)
Display StyleTouchscreen
Special FeaturesAdjustable Brightness, Alarm, Clock, Customizable Alert, Large Display
Included ComponentsAir Quality Detector x 1, Detector manual x 1, Adapter & USB Cable x 1

Warranty & Support

The Temtop M100 2nd Gen Air Quality Monitor comes with a 1-Year Limited Warranty (Detector Only). For support, please refer to the contact information provided in your product packaging or visit the official Temtop website.

Related Documents - M100 2nd

Preview Temtop M100 2nd Air Quality Monitor User Manual - Features, Specs, and Operation Guide
Comprehensive user manual for the Temtop M100 2nd Air Quality Monitor, detailing its features, specifications, operations, settings, and troubleshooting. Learn how to effectively monitor your indoor air quality with this advanced device.
Preview Temtop LKC-1000 Series Air Quality Monitor User Manual
User manual for the Temtop LKC-1000 Series Air Quality Monitor, detailing its functions, specifications, operation, and maintenance.
Preview Temtop P100/M100 Air Station User Manual: Comprehensive Air Quality Monitoring
User manual for the Temtop P100 and M100 Air Stations. Learn about monitoring PM2.5, PM10, CO2, temperature, and humidity with detailed explanations, specifications, and operational guides.
Preview Temtop M2000 Series Air Quality Monitor User Manual
User manual for the Temtop M2000 Series Air Quality Monitor, detailing its features, operation, specifications, and maintenance.
Preview Temtop C1 Series Air Quality Monitor: User Manual & Specifications
This user manual provides detailed information on the Temtop C1 Series Air Quality Monitor, covering its features, specifications, operation, calibration, troubleshooting, and warranty. It helps users understand and effectively use the device to monitor indoor air quality, including CO2, temperature, and humidity levels.
Preview Temtop M10/M10i Air Quality Monitor: PM2.5, HCHO, TVOC, AQI
Detailed overview of the Temtop M10 and M10i desktop air quality monitors. Features include 4-in-1 sensing (PM2.5, HCHO, TVOC, AQI), advanced sensors, easy operation, and wireless connectivity for M10i. View technical specifications and applications.