1. Introduction
Thank you for choosing the NCVI Electric Breast Pump F1 Pro. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your breast pump. Please read all instructions carefully before first use and retain this manual for future reference.
2. Important Safety Information
Always follow basic safety precautions when using electrical products, especially when children are present. Failure to follow these instructions could result in electric shock, fire, or serious injury.
- Do not immerse the pump motor unit in water or other liquids.
- Keep the pump and its components out of reach of children.
- Use only the power adapter provided with the device.
- Inspect all components before each use for damage or wear. Replace any damaged parts immediately.
- This product is a single-user device. Multiple users may pose a health risk.
- Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition.
3. Package Contents
The NCVI Electric Breast Pump F1 Pro package includes the following items:
- 1 x Pump Motor Unit
- 2 x 24mm Flanges
- 2 x Pump Body Assemblies
- 1 x Battery Charger
- 3 x Bottle Covers
- 2 x Nipples
- 3 x Bottles
- 2 x Air Tubes
- 2 x 17mm Flange Inserts
- 2 x 19mm Flange Inserts
- 2 x 21mm Flange Inserts
- 4 x Duckbill Valves
- 1 x Nipple Ruler
- Cooler Bag
- Pump Bag

Figure 1: Complete Package Contents
4. Product Components Overview
The NCVI F1 Pro features a thoughtful design for comfort and efficiency.

Figure 2: Micro-Vibration Technology for Enhanced Milk Flow
The pump incorporates micro-vibration technology to gently massage the breast, promoting a smoother let-down and reducing discomfort. This feature helps to ease engorgement and may assist in preventing clogged ducts.

Figure 3: Dual Independent Motor System
Equipped with dual independent motors, the F1 Pro allows for customized suction and rhythm settings for each breast, adapting to individual needs and maximizing comfort and efficiency.

Figure 4: Flange Size Guide for Optimal Fit
The kit includes multiple flange sizes (17mm, 19mm, 21mm, 24mm) to ensure a secure and comfortable fit, which is crucial for effective milk expression.
5. Setup and Assembly
Before first use, sterilize all parts that come into contact with breast milk. Ensure all components are completely dry before assembly.
- Clean and Sterilize: Wash all pump parts (flanges, connectors, duckbill valves, bottles, nipples, bottle covers) in warm soapy water, rinse thoroughly, and then sterilize according to manufacturer guidelines (e.g., boiling, steam sterilizer, or dishwasher safe).
- Assemble the Pump Body: Insert the duckbill valve firmly into the bottom of the connector. Attach the diaphragm to the top of the connector. Screw the flange onto the connector.
- Attach Bottle: Screw a clean bottle onto the assembled flange and connector unit.
- Connect Tubing: Insert one end of the air tube into the pump body assembly and the other end into the corresponding port on the motor unit. For single pumping, cap the unused port on the motor unit.
- Power On: Connect the power adapter to the pump motor unit and a power outlet, or ensure the built-in battery is charged.
Video 1: Overview of the NCVI Upgraded VibesFlow Breast Pump F1, demonstrating its features and components. (Duration: 0:52)
6. Operating Instructions
6.1 Powering On and Basic Operation
Press the power button to turn on the pump. The LED display will illuminate, showing the current mode, suction level, and time.

Figure 5: LED Touch Screen Display and Controls
6.2 Pumping Modes and Settings
The F1 Pro offers 4 distinct modes, 9 suction levels, and 5 cycle speeds to mimic natural nursing patterns and optimize milk expression.
- Massage Mode: Gentle, rapid suction to stimulate let-down.
- Expression Mode: Slower, stronger suction for efficient milk extraction.
- Simulation Mode: Mimics a baby's initial rapid suckling.
- Multitronic Mode: Combines different rhythms and suctions for varied stimulation.
Use the '+' and '-' buttons on the display to adjust suction levels and cycle speeds within each mode. The independent control feature allows you to set different modes, levels, and speeds for the left and right breasts simultaneously.
Video 2: A user's experience with the NCVI F1, highlighting its hospital-grade suction and customizable settings. (Duration: 4:37)
6.3 Night Light Function
The integrated soft night light provides illumination for nighttime pumping sessions without disturbing rest. It features 3 adjustable brightness levels. Activate and adjust the night light using the dedicated button on the control panel.

Figure 6: Night Light for Discreet Pumping
6.4 Battery Life
The F1 Pro is equipped with a built-in 5600mAh rechargeable lithium battery, providing extended use for multiple pumping sessions on a single charge. This allows for portable and flexible pumping without being tethered to a power outlet.
Video 3: A user sharing their real experience with the NCVI Breast Pump F1, focusing on its features and ease of use. (Duration: 0:42)
7. Cleaning and Maintenance
Proper cleaning and maintenance are essential for hygiene and the longevity of your breast pump. The F1 Pro features a closed system design to prevent milk backflow into the tubing and motor unit, simplifying cleaning.
7.1 Daily Cleaning
After each use, disassemble all parts that come into contact with breast milk (flanges, connectors, duckbill valves, bottles). Wash them immediately in warm soapy water, rinse thoroughly with clean water, and allow to air dry on a clean surface or use a dedicated drying rack. All milk-contacting parts are dishwasher safe.

Figure 7: Simple Assembly and Easy Cleaning
7.2 Sterilization
Sterilize all milk-contacting parts at least once a day. Methods include boiling water for 5 minutes, using a steam sterilizer, or following your dishwasher's sanitize cycle instructions.
7.3 Motor Unit Care
Wipe the motor unit with a clean, damp cloth. Do not immerse the motor unit in water or sterilize it. Ensure the motor unit is dry before storage or next use.
8. Troubleshooting
If you encounter issues with your NCVI Electric Breast Pump F1 Pro, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No suction or weak suction |
|
|
| Pump not turning on |
|
|
| Unusual noise from motor unit |
|
|
| Milk flowing back into tubing |
|
|
If the problem persists after attempting these solutions, please contact NCVI customer support.
9. Specifications
- Model Number: AM8129
- Power Source: Battery Powered (5600mAh rechargeable lithium battery)
- Suction Strength: Up to 320 mmHg (Hospital-Grade)
- Modes: 4 (Massage, Expression, Simulation, Multitronic)
- Suction Levels: 9
- Cycle Speeds: 5
- Noise Level: 42 Decibels
- Capacity (Bottles): 6 ounces (per bottle)
- Material Type: Polypropylene
- Material Type Free: BPA Free
- Dishwasher Safe: Yes (milk-contacting parts)
- Additional Features: Adjustable Suction, Closed System, LCD Display, Night Light, Micro-Vibration, Independent Dual Control
- Package Dimensions: 16.93 x 13.35 x 6.65 inches
- Item Weight: 7.94 Pounds
10. Warranty and Support
For warranty information, product support, or to purchase replacement parts, please contact NCVI customer service. Keep your purchase receipt as proof of purchase.
- Manufacturer: NCVI
- Seller: NCVI-XENBEI
- Return Policy: 90-day refund/replacement policy (as per Amazon listing at time of data extraction). Specific warranty details may vary; refer to your product packaging or contact the manufacturer directly.