Green Cell UPSLP700

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Green Cell UPS 1000VA 700W PowerProof with LCD Display User Manual

Model: UPSLP700

1. Introduction and Overview

The Green Cell UPS 1000VA 700W PowerProof is an Uninterruptible Power Supply designed to protect your sensitive electronic devices from power outages, surges, and voltage fluctuations. It ensures continuous operation of critical equipment, preventing data loss and hardware damage. This manual provides essential information for the safe and efficient use of your UPS.

Diagram illustrating what a UPS is and its application, showing three Green Cell UPS units.

Image 1.1: What is a UPS? An uninterruptible power supply (UPS) provides temporary power during outages, protecting against data loss and equipment damage. It is ideal for both home and business use, ensuring continuous operation of critical equipment.

Icons representing various applications for a UPS, including consumer electronics, alarm systems, computers, cash registers, and routers.

Image 1.2: UPS Applications. UPS units are widely used to ensure continuous power for devices in various settings, including consumer electronics, alarm systems, computers, cash registers, and routers.

2. Safety Information

Please read and follow all safety instructions carefully before installing, operating, or maintaining the UPS. Failure to do so may result in electric shock, fire, or serious injury.

  • Electrical Safety: The UPS operates with high voltage. Do not open the UPS casing. There are no user-serviceable parts inside. Refer all servicing to qualified service personnel.
  • Battery Safety: The UPS contains sealed lead-acid batteries. Do not dispose of batteries in a fire, as they may explode. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes.
  • Placement: Install the UPS in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure adequate clearance around the unit for proper airflow.
  • Overload: Do not overload the UPS. The total power consumption of connected equipment should not exceed the UPS's rated capacity.
  • Grounding: Always connect the UPS to a grounded power outlet.

3. Package Contents

Carefully unpack the box and ensure all items are present. If any items are missing or damaged, please contact your retailer.

  • Green Cell UPS 1000VA 700W PowerProof Unit
  • User Manual (this document)
  • Power Cable(s)
  • USB Communication Cable

4. Product Features

The Green Cell UPS 1000VA 700W PowerProof is equipped with advanced features to ensure reliable power protection for your devices.

  • Reliable Power Protection: Safeguards sensitive devices like computers, routers, and network equipment from power outages, surges, and voltage fluctuations.
  • LCD Display: Provides clear information on the UPS's operational status, including battery status, input/output voltage, and error/warning alerts.
  • Uninterrupted Power Supply: Features a fast switching time of 2-6 ms, ensuring devices continue to operate without interruption during power failures.
  • Long-lasting Emergency Power: Equipped with 2 x 12V/7Ah batteries, offering reliable emergency power until mains power is restored.
  • Comprehensive Surge Protection: Protects against surges and short circuits, safeguarding valuable devices and data.
  • Automatic Voltage Regulation (AVR): Stabilizes voltage fluctuations, providing clean and consistent power to connected devices.
  • Cold Start Mode: Allows the UPS to be powered on directly from its batteries without being connected to the mains power.
  • USB/RJ45 Ports: Includes dedicated RJ45 ports for surge protection of network devices and a USB port for communication with a computer.
Close-up of the UPS LCD display showing input voltage, output voltage, battery charge level, working mode, and load level indicators.

Image 4.1: LCD Display. The LCD display provides real-time information on output voltage, input voltage, charge level, working mode, and load level for easy monitoring.

Diagram highlighting the simple connection, immediate device protection, additional RJ45 ports, protection against overload/discharge/overcurrent, and fast switching time of the UPS.

Image 4.2: Simple Connection and Protection. This image illustrates the UPS's features such as additional RJ45 ports, protection against overload, discharge, and overcurrent, and a fast switching time for immediate device protection.

A person using a laptop with the UPS visible on the floor, illustrating voltage control via the AVR system for equipment safety.

Image 4.3: Voltage Control with AVR. The Automatic Voltage Regulation (AVR) system ensures stable voltage, protecting your equipment from fluctuations.

A photographer using equipment powered by the UPS, demonstrating the cold start mode feature.

Image 4.4: Cold Start Mode. The UPS can be used without being connected to the mains, allowing for operation directly from its internal batteries.

Diagram comparing pure sine wave and modified sine wave UPS outputs, explaining which devices are suitable for each type.

Image 4.5: Pure vs. Modified Sine Wave. The Green Cell UPS provides a pure sine wave output, which is essential for sensitive electronics and appliances with induction motors, ensuring stable and clean power.

5. Setup

Follow these steps to set up your Green Cell UPS:

  1. Placement: Place the UPS on a flat, stable surface in a clean, well-ventilated area. Avoid placing it near heat sources, direct sunlight, or excessive moisture. Ensure there is at least 10 cm of clearance around the unit for proper airflow.
  2. Initial Charging: Connect the UPS to a grounded wall outlet using the provided power cable. Allow the UPS to charge for at least 8-12 hours before connecting any devices. This ensures the batteries are fully charged and ready to provide backup power.
  3. Connecting Devices: Once the UPS is fully charged, connect your electronic devices (e.g., computer, monitor, router) to the output sockets on the back of the UPS. Ensure the total load does not exceed the UPS's rated capacity (700W).
  4. Network/Data Line Protection (Optional): If desired, connect your network cable (RJ45) through the UPS's surge-protected RJ45 ports to protect your network devices from surges.
  5. USB Communication (Optional): Connect the USB cable from the UPS to your computer to enable monitoring and management software (if applicable).
Front-side view of the Green Cell UPS 1000VA 700W PowerProof with LCD display and power button.

Image 5.1: Front View of UPS. This image shows the front and side of the Green Cell UPS, highlighting its compact design and LCD display.

6. Operating Instructions

Understanding how to operate your UPS ensures optimal performance and protection.

6.1 Turning On/Off

  • To Turn On: Press and hold the power button on the front panel for approximately 3 seconds until you hear a beep and the LCD display illuminates.
  • To Turn Off: Press and hold the power button for approximately 3 seconds until the display turns off and the unit powers down.

6.2 LCD Display Indicators

The LCD display provides real-time status information:

  • Input Voltage: Shows the current voltage from the mains power supply.
  • Output Voltage: Displays the voltage supplied by the UPS to connected devices.
  • Battery Level: Indicates the remaining battery charge.
  • Load Level: Shows the percentage of the UPS's capacity being used by connected devices.
  • Working Mode: Indicates if the UPS is operating on mains power, battery power, or in AVR mode.
  • Error/Warning Icons: Alerts to specific issues such as overload, low battery, or fault conditions.

6.3 Cold Start Function

The cold start function allows you to power on the UPS and connected devices using only battery power, even when there is no mains power available. To activate, ensure the UPS is off, then press and hold the power button for approximately 5-7 seconds until the UPS starts and provides power from its batteries.

7. Maintenance

Proper maintenance ensures the longevity and reliability of your UPS.

  • Battery Care: To maximize battery life, keep the UPS connected to mains power to ensure batteries remain charged. If the UPS is stored for an extended period, recharge it every three months for at least 8 hours.
  • Battery Replacement: Batteries have a limited lifespan. When the battery capacity significantly decreases, it may need replacement. Contact qualified service personnel for battery replacement.
  • Cleaning: Periodically clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and obstructions.
  • Storage: Store the UPS in a cool, dry place with adequate ventilation. Ensure batteries are fully charged before storage.

8. Troubleshooting

This section addresses common issues you might encounter with your UPS.

ProblemPossible CauseSolution
UPS does not turn onNo mains power; Low battery; Power button not pressed correctlyCheck power cord connection; Allow UPS to charge; Press and hold power button for 3 seconds.
UPS beeps continuouslyOverload; Low battery; Fault conditionReduce connected load; Allow UPS to charge; Refer to LCD error codes or contact support.
Short backup timeOverload; Batteries not fully charged; Batteries reaching end of lifeReduce connected load; Ensure UPS is fully charged; Consider battery replacement.
UPS does not provide power to devicesUPS is off; Output sockets not enabled; Fault conditionTurn on UPS; Check if devices are properly plugged in; Contact support if fault persists.

9. Specifications

Detailed technical specifications for the Green Cell UPS 1000VA 700W PowerProof (Model UPSLP700).

FeatureSpecification
BrandGreen Cell
ModelUPSLP700
Product Dimensions20.5 x 34 x 14.6 cm
Item Weight9.16 Kilograms
Output Power (Watts)700 Watts
Voltage230 Volts
Batteries2 x 12V (included)
Battery Cell CompositionLead Acid
Number of Items1

10. Warranty and Support

Green Cell products are designed for reliability and performance. This product comes with a standard manufacturer's warranty against defects in materials and workmanship.

  • Warranty Information: For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Green Cell website.
  • Technical Support: If you encounter any issues or have questions regarding the operation or maintenance of your Green Cell UPS, please contact Green Cell customer support. Contact details can typically be found on the official Green Cell website or in the product packaging.
  • Online Resources: Visit the Green Cell website for FAQs, updated manuals, and additional support resources.

© 2026 Green Cell. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.