Temtop T1-SE

Temtop Indoor Thermometer Hygrometer T1-SE User Manual

Precision Digital Temperature and Humidity Monitor

1. Introduction

The Temtop T1-SE is a precision digital indoor thermometer and hygrometer designed to monitor temperature and humidity levels in various indoor environments. This device provides real-time data, comfort level indicators, and includes date and time functions, making it a versatile tool for maintaining optimal indoor conditions.

Temtop T1-SE Indoor Thermometer Hygrometer displaying temperature, humidity, comfort level, and time.

Figure 1: Temtop T1-SE device displaying current temperature, humidity, comfort level, and time.

2. Safety Information

  • Keep the device away from water and excessive moisture to prevent damage.
  • Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
  • Do not attempt to disassemble or repair the device yourself. Refer to qualified personnel for service.
  • Keep out of reach of children.
  • Dispose of batteries according to local regulations.

3. Product Overview

3.1 Package Contents

The package includes the following items:

  • Temtop T1-SE Indoor Thermometer Hygrometer
  • User Manual
  • 3M Adhesive Sticker with Metal Plate
  • Charging Cable (for models with rechargeable battery, though this model uses a coin battery)

3.2 Device Features

The Temtop T1-SE offers several key features for comprehensive indoor climate monitoring:

  • Temperature and Humidity Monitoring: Provides accurate readings with 10-second updates.
  • Comfort Indicator: Color-coded alerts (Red for Dry, Green for Comfort, Blue for Wet) for quick environmental assessment.
  • Large Display: Extra-large 3.7-inch display with bold, glare-resistant digits for easy readability.
  • Multiple Mounting Options: Features a strong built-in magnet, 3M adhesive sticker, and a foldable stand.
  • Date and Time Display: Includes a 12/24-hour clock and date (month, day, year).
  • Temperature Unit Switch: Easily switch between Celsius (°C) and Fahrenheit (°F).
Temtop T1-SE device showing temperature, humidity, comfort levels, and date/time on a large display.

Figure 2: Overview of the Temtop T1-SE's display and core functions.

4. Setup

4.1 Battery Activation

The Temtop T1-SE is powered by a CR2032 coin battery (included). To activate the device:

  1. Locate the battery compartment on the back of the device.
  2. Open the battery compartment cover.
  3. Gently pull and remove the transparent insulating tab from the battery slot. This tab prevents battery drain during storage.
  4. Close the battery compartment cover securely. The device screen will illuminate automatically.

Video 1: Demonstrates the battery activation process for the Temtop T1-SE.

4.2 Placement Options

The T1-SE offers flexible placement to suit your needs:

  • Magnetic Mounting: Utilize the strong built-in magnet to attach the device to metal surfaces like refrigerators.
  • Adhesive Mounting: Use the provided 3M adhesive sticker with a metal plate to mount the device on walls or other non-metal surfaces.
  • Freestanding: Deploy the collapsible multi-angle support stand for desktop or shelf placement.
Temtop T1-SE mounted on a refrigerator using its magnet.

Figure 3: Temtop T1-SE mounted on a metal surface using its magnetic back.

Temtop T1-SE standing on a desk using its collapsible stand.

Figure 4: Temtop T1-SE utilizing its collapsible stand for desktop use.

5. Operating Instructions

5.1 Display Overview

The large LCD screen displays the following information:

  • Current Temperature (°C/°F)
  • Current Humidity (%)
  • Comfort Level Indicator (DRY, COMFORT, WET)
  • Time (AM/PM, 12/24H format)
  • Date (Month/Day/Year)
Temtop T1-SE display showing temperature, humidity, comfort indicator, and date/time.

Figure 5: Detailed view of the T1-SE's digital display.

5.2 Setting Time and Date

To set the time and date:

  1. Press and hold the SET button (located on the back) for 3 seconds. The hour digits will start flashing.
  2. Use the + or - buttons to adjust the hour. Press and hold for faster adjustment.
  3. Press SET again to confirm the hour and move to minute setting. Repeat the adjustment process.
  4. Continue pressing SET to cycle through and adjust Year, Month, and Day.
  5. After setting the Day, press SET one last time to exit the setting mode.

Video 2: Demonstrates the battery activation process for the Temtop T1-SE.

5.3 Switching Temperature Units (°C/°F)

To switch between Celsius and Fahrenheit:

  • Briefly press the + button (located on the back) to toggle between °C and °F.
Temtop T1-SE display showing temperature in Fahrenheit and Celsius.

Figure 6: Illustration of switching between Celsius and Fahrenheit temperature units.

5.4 Comfort Level Indicators

The device features a color-coded bar to indicate the comfort level based on humidity:

  • RED (DRY): Humidity below 40% RH.
  • GREEN (COMFORT): Humidity between 40% and 69% RH.
  • BLUE (WET): Humidity between 70% and 95% RH.
Temtop T1-SE display showing color-coded comfort zones for humidity: Dry (Red), Comfort (Green), Wet (Blue).

Figure 7: Explanation of the color-coded comfort level indicators on the display.

6. Maintenance

  • Clean the device regularly with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Ensure the air vents on the device are not obstructed to allow for accurate readings.
  • If the display becomes dim or unresponsive, replace the CR2032 coin battery.

7. Troubleshooting

ProblemPossible CauseSolution
No display or dim displayBattery not activated or low battery.Ensure the insulating tab is fully removed. Replace the CR2032 battery if necessary.
Inaccurate readingsDevice placed near heat/cold sources or in direct airflow. Vents obstructed.Relocate the device to a stable environment away from extreme conditions. Ensure vents are clear.
Cannot set time/dateButtons not pressed correctly or device unresponsive.Press and hold the SET button firmly for 3 seconds. If unresponsive, try removing and reinserting the battery.

8. Specifications

SpecificationValue
Model NumberUS-T1SE
Temperature Measuring Range14°F - 122°F (-10°C - 50°C)
Temperature Accuracy±1.8°F (±1°C)
Humidity Measuring Range10% - 95% RH
Humidity Accuracy±5% RH (for 40-80% RH)
Update RateEvery 10 seconds
Display Size3.7 inches
Power Source1 x CR2032 Nonstandard Battery (included)
Product Dimensions2.76 x 2.76 x 0.55 inches (70 x 70 x 14 mm)
Item Weight2.08 ounces (57g)

9. Warranty and Support

Temtop products typically come with a one-year detector warranty. For specific warranty details, product support, or technical assistance, please refer to the contact information provided in your product packaging or visit the official Temtop website. Temtop is manufactured by Elitech.

For additional resources and information, you may visit the Temtop Store on Amazon.

Related Documents - T1-SE

Preview Temtop M10/M10i Air Quality Monitor: PM2.5, HCHO, TVOC, AQI
Detailed overview of the Temtop M10 and M10i desktop air quality monitors. Features include 4-in-1 sensing (PM2.5, HCHO, TVOC, AQI), advanced sensors, easy operation, and wireless connectivity for M10i. View technical specifications and applications.
Preview Temtop S1+ Air Quality Monitor User Manual
Comprehensive user manual for the Temtop S1+ Air Quality Monitor, detailing features, specifications, operation, and troubleshooting for monitoring PM2.5 and AQI.
Preview Temtop S1 Air Quality Monitor User Manual - PM2.5 & AQI Detector
Comprehensive user manual for the Temtop S1 Air Quality Monitor. Learn about PM2.5, AQI, temperature, and humidity readings, device specifications, operation, troubleshooting, and warranty information.
Preview Temtop S1+ Air Quality Monitor User Manual
Learn about the Temtop S1+ Air Quality Monitor, a device for tracking indoor PM2.5, temperature, and humidity. This manual covers features, specifications, operation, and troubleshooting for a healthier environment.
Preview Temtop C1 Series Air Quality Monitor: User Manual & Specifications
This user manual provides detailed information on the Temtop C1 Series Air Quality Monitor, covering its features, specifications, operation, calibration, troubleshooting, and warranty. It helps users understand and effectively use the device to monitor indoor air quality, including CO2, temperature, and humidity levels.
Preview Temtop M2000 Air Quality Detector User Manual - Elitech Technology
User manual for the Temtop M2000 Hand-Held Air Quality Detector by Elitech Technology. Learn about its features, operation, specifications, and health standards for monitoring PM2.5, PM10, CO2, and HCHO.