Introduction
This manual provides essential information for the safe and effective use of your COOSPIDER UVC Light Lamp. Please read all instructions carefully before operation to ensure proper usage and to prevent potential hazards.
Important Safety Information
WARNING: UVC Radiation Hazard
- Direct Exposure: Direct exposure to UVC light is harmful to skin and eyes. Never look directly at the operating lamp.
- Humans, Pets, and Plants: Ensure no humans, pets, or plants are present in the area when the lamp is operating. Clear the space completely before activation.
- Operation Time: Recommended usage is 30 minutes per session. Do not exceed recommended exposure times without proper ventilation.
- Ventilation: After each use, the treated space must be ventilated for at least 30 minutes by opening windows or using a fan. Do not re-enter the area until ventilation is complete.
- Installation: Install the lamp in a location where accidental exposure is prevented and where it cannot be easily accessed by children or pets.
Package Contents
Verify that all items listed below are included in your package:
- 1 x UVC Light Bulb (185nm with 253.7nm)
- 1 x Bulb Base (G5)
- 1 x 5-foot Power Cord with Plug
- 2 x Screws
- 1 x Connector (for linking two bulbs, if applicable)

Specifications
| Feature | Detail |
|---|---|
| Brand | COOSPIDER |
| Model Number | CTUV-6 |
| Light Type | Mercury Vapor (UVC) |
| Wavelengths | 185nm with 253.7nm |
| Wattage | 6 watts |
| Bulb Base | G5 |
| Power Cord Length | 5 feet (150cm) |
| Voltage | 110 Volts |
| Material | Glass |
| Service Life | Up to 8000 hours |
| EPA EST NO. | 96998-CHN-1 |
Setup Instructions
Follow these steps to set up your UVC Light Lamp:
- Unpack: Carefully remove all components from the packaging. Inspect for any damage.
- Mounting: Choose a suitable, secure location for the lamp. Ensure the chosen spot is away from areas where direct exposure to UVC light could occur during operation. Use the provided screws or double-sided tape to mount the bulb base firmly.
- Insert Bulb: Gently insert the UVC light bulb into the G5 bulb base. Ensure it is seated correctly and securely.
- Connect Power: Plug the 5-foot power cord into the bulb base, then into a standard 110V electrical outlet.
- Optional Connection: If you are linking multiple bulbs, use the provided connector to join them before connecting the power cord to the first bulb base.

Operating Instructions
Follow these steps for safe operation of your UVC Light Lamp:
- Clear Area: Before turning on the lamp, ensure that the area to be treated is completely clear of all humans, pets, and plants. Verify that no one can accidentally enter the space during operation.
- Activate: Turn on the lamp using the switch located on the power cord. The lamp will emit UVC light.
- Run Time: Allow the lamp to operate for approximately 30 minutes per session. Do not leave the lamp unattended while in operation.
- Deactivate: After the desired operation time, turn off the lamp using the switch and unplug it from the electrical outlet.
- Ventilate: Immediately after turning off the lamp, ventilate the treated space for at least 30 minutes by opening windows or using a fan. Do not re-enter the area until ventilation is complete.

Maintenance
Proper maintenance ensures the longevity and effectiveness of your UVC Light Lamp:
- Cleaning: Periodically wipe the bulb with a dry, soft cloth to remove dust or debris. Do not use liquid cleaners or abrasive materials. Always ensure the lamp is unplugged and cool before cleaning.
- Bulb Replacement: The bulb has an estimated service life of up to 8000 hours. Replace the bulb when its effectiveness diminishes or it ceases to function. Ensure the replacement bulb matches the original specifications (G5 base, 6W, 185nm with 253.7nm).
- Storage: When not in use for extended periods, store the lamp in a cool, dry place, away from direct sunlight and moisture. Keep it out of reach of children and pets.
Troubleshooting
If you encounter issues with your UVC Light Lamp, refer to the following common problems and solutions:
Lamp Does Not Turn On:
- Power Connection: Check if the power cord is securely plugged into both the bulb base and a functional electrical outlet.
- Outlet Functionality: Test the electrical outlet with another device to ensure it is providing power.
- Bulb Seating: Ensure the bulb is correctly and fully seated in the G5 base.
- Bulb Life: If the bulb has been used for an extended period (over 8000 hours), it may have reached the end of its service life and require replacement.
Reduced Effectiveness:
- Bulb Cleanliness: Dust or debris accumulated on the bulb surface can reduce its UVC output. Clean the bulb as per the maintenance instructions.
- Bulb Age: The intensity of UVC bulbs naturally diminishes over time. If the bulb is nearing the end of its estimated service life, consider replacing it for optimal performance.
Warranty and Support
For any issues, questions, or warranty claims regarding your COOSPIDER UVC Light Lamp, please refer to the contact information provided on the product packaging. The manufacturer, Aopu Lighting Co. Ltd, is committed to customer satisfaction and aims to respond to inquiries within 48 hours.
COOSPIDER focuses on providing specialized solutions and prioritizes customer support. If you encounter any problems or require assistance, please reach out to the support channels indicated on the product packaging or visit the official COOSPIDER store for further information.
For more information, you can visit the COOSPIDER Store.