Introduction
This manual provides detailed instructions for the safe and effective use of your HURRISE 4-in-1 80K Cavitation Machine. This multifunctional device combines 80K cavitation, radiofrequency (RF) for face and body, and vacuum therapy to address various skin concerns. Please read this manual thoroughly before operation and keep it for future reference.
Safety Information
Important Safety Precautions:
- For external use only.
- Do not use on broken, irritated, or infected skin.
- Consult a physician before use if you have any medical conditions, including but not limited to heart disease, pacemakers, epilepsy, cancer, or are pregnant.
- Avoid using on sensitive areas such as eyes, thyroid gland, or lymph nodes.
- Always use the device with a suitable conductive gel, cream, or oil.
- Do not stay in the same area for too long during treatment to prevent skin irritation or burns.
- Keep out of reach of children.
- Ensure the device is unplugged when not in use or during cleaning.
- Do not immerse the device or its components in water.
Product Components
The HURRISE 4-in-1 Cavitation Machine includes the following components:
- 1 x Main Device
- 1 x 80K Cavitation Handle
- 1 x 3-Polar RF Handle (for face)
- 1 x 4-Polar RF Handle (for body)
- 1 x Vacuum RF Handle
- 1 x Power Adapter
- 1 x User Manual
- 1 x External Filter (improved)

Figure 1: Main device and various treatment handles. The image shows the main unit with connections for the 80K cavitation handpiece, vacuum and heat probes, 3-polar RF handle, and 4-polar RF handle, each designed for specific functions like skin tightening and fat reduction.

Figure 2: Multifunction Beauty Instrument with labeled heads. This image displays the main unit and its four distinct heads: the tripolar head, the 4-pole head, the 80K cavitation head, and the vacuum handle, illustrating the comprehensive nature of the device.
Setup
- Unpack: Carefully remove all components from the packaging.
- Inspect: Check all parts for any signs of damage.
- Connect Handles: Attach the desired treatment handles to their corresponding ports on the main device. Ensure they are securely fastened.
- Connect Power: Plug the power adapter into the main device, then plug the adapter into a suitable power outlet.
- External Filter: For the vacuum handle, ensure the external filter is properly attached to prolong device life.

Figure 3: Rear view of the device showing connection ports. This image highlights the various ports on the back of the main unit where the power cable and different treatment handles are connected, ensuring a secure setup.
Operating Instructions
Before starting any treatment, ensure your skin is clean and apply a generous amount of conductive gel, cream, or oil to the treatment area. The device features a sensitive touch screen for easy operation and function selection.
General Usage Steps:
- Clean the skin thoroughly.
- Apply a small amount of conductive gel to the treatment area.
- Turn on the device using the power button.
- Select the desired function and adjust settings (time, energy level) on the touch screen.
- Gently slide the chosen handle over the skin in circular or linear motions, following recommended treatment patterns.
- Follow the recommended treatment time (15-20 minutes per session, 3 times per week).
- After treatment, turn off the device, clean off any remaining gel, and moisturize the skin.

Figure 4: User interface for 80K Cavitation. This image illustrates the device's touch screen, showing controls for setting treatment time (0-60 minutes) and energy levels (1-10 levels), along with return and start/pause buttons.
Specific Handle Functions:
1. 80K Cavitation Handle
This handle uses 80KHz ultrasonic waves to target localized fat deposits. It vibrates 80,000 times per second, generating heat and micro-bubbles that break down fat cells. Use on areas like the abdomen, thighs, and arms.

Figure 5: Application of the 80K Cavitation handle. The image shows the 80K cavitation handle being gently moved across the abdominal area, demonstrating its use for targeted fat reduction.

Figure 6: 80K Cavitation handle in use. This image depicts the 80K cavitation handle being applied to a person's thigh, illustrating the technique for body contouring.
2. 3-Polar RF Handle (for Face)
The 3-polar RF handle uses radiofrequency energy to stimulate collagen production, helping to tighten and lift facial skin. Suitable for areas such as the forehead, eye contours, cheeks, mouth, double chin, and neck.

Figure 7: Facial application of the 3-Polar RF handle. This image shows the 3-polar RF handle being used on a person's face, demonstrating its application for facial lifting and skin firming.

Figure 8: 3D RF Radiofrequency for facial treatment. This image illustrates the use of the RF handle for facial lifting and skin firming, highlighting common application areas on the face.
3. 4-Polar RF Handle (for Body)
The 4-polar RF handle is designed for larger body areas, providing deeper penetration of radiofrequency energy to firm and restore skin elasticity. Use on areas such as the abdomen, waist, hips, and legs.

Figure 9: Body application of the 4-Polar RF handle. The image shows the 4-polar RF handle being applied to a person's arm, demonstrating its use for firming and improving skin elasticity on body areas.
4. Vacuum RF Handle
This handle combines vacuum suction with RF energy to massage the skin, improve circulation, and help with body contouring and cellulite reduction. It can also be used for cupping therapy.

Figure 10: Vacuum RF handle for body contouring. This image illustrates the vacuum RF handle in use for skin firming and 3D RF vacuum therapy, showing its application on various body parts.
Maintenance
- Cleaning: After each use, wipe the treatment handles and the main device with a soft, damp cloth. Do not use abrasive cleaners or immerse in water.
- Storage: Store the device and its accessories in a cool, dry place, away from direct sunlight and moisture.
- Filter Maintenance: Regularly check and clean the external filter for the vacuum handle to ensure optimal performance and device longevity. Replace if necessary.
- Cable Care: Avoid bending or twisting the power cord and handle cables excessively to prevent damage.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Power cord not properly connected; Power outlet malfunction. | Ensure power cord is securely plugged into the device and outlet. Try a different outlet. |
| No sensation or weak sensation during treatment. | Insufficient conductive gel; Low energy setting; Handle not making full contact with skin. | Apply more conductive gel. Increase energy level gradually. Ensure full contact of the handle with the skin. |
| Skin redness or discomfort. | Energy setting too high; Staying in one area for too long; Insufficient gel. | Reduce energy setting. Keep the handle moving constantly. Apply more gel. If discomfort persists, discontinue use. |
| Vacuum function is weak. | External filter is clogged; Handle not sealed properly on skin. | Clean or replace the external filter. Ensure the vacuum handle forms a tight seal with the skin. |
Specifications
- Brand: HURRISE
- Model Name: 4-in-1 Cavitation
- ASIN: B0FH4XPZFB
- Manufacturer Reference: 32423423
- Material: Acrylonitrile Butadiene Styrene (ABS)
- Color: White
- Package Dimensions: 36.1 x 27.4 x 19.2 cm
- Item Weight: 3.48 kg
- Country of Origin: China
- Included Components: 1 main device, 4 probes (handles), 1 manual
Warranty and Support
For warranty information and customer support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase for any warranty claims.
Manufacturer: HURRISE
For further assistance, please visit the HURRISE Store on Amazon.