1. Introduction
This manual provides detailed instructions for the safe and effective use of the FeelTech ZT-DQ01 Handheld Digital LCR Meter. Please read this manual thoroughly before operation.
The ZT-DQ01 is a high-precision handheld digital bridge LCR meter designed for measuring capacitance, resistance, and inductance. It features a 2.8-inch full-view angle color screen and supports true four-wire measurement.

Image 1: FeelTech ZT-DQ01 LCR Meter and included accessories.
2. Key Features
- Handheld digital high-precision bridge tester for LCR measurement.
- Measures resistance, capacitance, and inductance with true four-wire L/C/R/Z value display.
- Equipped with a 2.8-inch full-view angle color screen.
- Automatic identification of resistors, capacitors, and inductors.
- Features an adjustable auto power-off function for energy saving; compact and portable design.

Image 2: Overview of the ZT-DQ01's main features, including true four-wire measurement and L/C/R/Z value display.
3. Setup and Initial Use
3.1 Unpacking
Carefully unpack the ZT-DQ01 LCR Meter and all accessories. Verify that all components listed in the "What's in the Box" section are present:
- ZT-DQ01 LCR Meter
- Test leads
- USB Type-C charging cable
- Carrying pouch
3.2 Charging the Device
The ZT-DQ01 is powered by a 400mA lithium battery. Before first use, fully charge the device using the provided USB Type-C cable and a compatible USB power adapter (not included).

Image 3: The 2.8-inch color screen and Type-C charging port of the ZT-DQ01.
3.3 Connecting Test Leads
Connect the provided test leads to the appropriate input terminals on the LCR meter. Ensure a secure connection for accurate measurements. The meter supports true four-wire measurement for enhanced precision.

Image 4: The ZT-DQ01 LCR Meter connected to a component for testing, demonstrating automatic identification.
4. Operating Instructions
4.1 Power On/Off
Press and hold the power button (ⓘ) to turn the device on or off.
4.2 Basic Measurement
The ZT-DQ01 features automatic identification of resistors, capacitors, and inductors. Simply connect the component to the test leads, and the meter will automatically detect the component type and display the relevant parameters (L, C, R, Z, X, D, Q, θ, ESR).
4.3 Function Buttons
- FREQ: Adjusts the test frequency (100Hz, 120Hz, 1KHz, 10KHz, 100KHz).
- LEVEL: Sets the test level (0.1V, 0.3V, 0.6V).
- SPEED: Adjusts the measurement speed (Slow, Medium, Fast).
- X/D/Q/θ/ESR: Cycles through displayed sub-parameters.
- AUTO/S/P SETUP: Automatic series/parallel mode setup.
- LCRZ: Selects the main measurement parameter (Inductance, Capacitance, Resistance, Impedance).
- HOLD/REC: Holds the current measurement or enters record mode.
- REL TOL%: Relative measurement and tolerance percentage.
4.4 Discharging Capacitors
WARNING: Always discharge capacitors before testing to prevent damage to the meter or injury.

Image 5: Detailed view of the ZT-DQ01's control panel and display, illustrating various functions.
5. Maintenance
5.1 Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off before cleaning.
5.2 Storage
Store the LCR meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying pouch for protection.
5.3 Calibration
The ZT-DQ01 supports bridge calibration for short circuit and open circuit. Refer to the on-screen menu for calibration procedures to maintain measurement accuracy.
6. Troubleshooting
- No Power: Ensure the battery is charged. Connect the USB Type-C cable to charge.
- Inaccurate Readings:
- Check test lead connections.
- Perform bridge calibration (short circuit, open circuit).
- Ensure the component is properly discharged before testing.
- Verify correct test frequency and level settings.
- Display Issues: Adjust backlight brightness if the screen is too dim or bright.
7. Technical Specifications
| Parameter | Value/Range |
|---|---|
| Model Number | ZT-DQ01 |
| Display | 2.8-inch full view angle color screen |
| Measurement Parameters | L, C, R, Z, X, D, Q, θ, ESR |
| Resistance Range | 0Ω - 20MΩ |
| Capacitance Range | 0pF - 100mF |
| Inductance Range | 0nH - 100H |
| Test Frequencies | 100Hz, 120Hz, 1KHz, 10KHz, 100KHz |
| Test Levels | 0.1V, 0.3V, 0.6V |
| Accuracy | Up to 0.3% |
| Battery | 400mA Lithium Battery |
| Charging Interface | USB Type-C |
| Dimensions | 146 x 30 x 18 mm |
| Weight | 1 Kilogram (approx. 2.2 lbs) |
| Certifications | CE, RoHS |

Image 6: Detailed technical specifications table for the ZT-DQ01 LCR Meter.
8. Applications
The FeelTech ZT-DQ01 LCR Meter is suitable for a wide range of applications, including:
- Equipment Maintenance
- Scientific Research and Education
- Production Testing
- Electronic Engineering Development

Image 7: Illustrates various applications of the ZT-DQ01 LCR Meter in different fields.
9. Warranty and Support
This product comes with a standard manufacturer's warranty. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Please refer to your purchase documentation for specific warranty terms and contact information.
EU Spare Part Availability Duration: 1 Year.