1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your TRUPOW 1HP Submersible Water Pump, Model TP-0818A. Please read these instructions carefully before use and retain them for future reference.

TRUPOW 1HP Submersible Water Pump with 25ft. Hose Kit

Image 1.1: TRUPOW 1HP Submersible Water Pump with included hose and adapters.

Key Features:

  • High Efficiency: 1HP motor moves up to 3980 gallons per hour (GPH) with a maximum vertical lift of 28 feet.
  • Durable Construction: Full thermoplastic housing and solid copper motor windings ensure longevity and reliable performance.
  • Overheat Protection: Automatic disconnection feature protects the motor from overheating.
  • Removable Bottom Screen: Easy-to-clean inlet strainer prevents coarse dirt from entering the pump, maintaining optimal operation.
  • Low Suction Capability: Can remove water down to 8mm (approximately 0.3 inches).
  • Portable Design: Compact and lightweight with a built-in handle and 16.4ft power cable for easy transport and installation.
  • Versatile Connections: Includes 1" NPT discharge size, a 3/4" garden hose adapter, and a 25ft water hose.

2. Safety Information

Always observe basic safety precautions to reduce the risk of fire, electric shock, and personal injury.

  • Electrical Safety: Ensure the power supply matches the pump's specifications (110-120V/60Hz). Do not operate the pump with a damaged cord or plug. Do not pull the pump by its power cord.
  • Water Temperature: Do not pump liquids hotter than 95°F (35°C).
  • Submersion: This pump is designed for submersible use only. Ensure it is fully submerged during operation to prevent dry running and motor damage.
  • Debris: Avoid pumping highly corrosive, flammable, or explosive liquids. The pump is designed for clean water with particles up to 4mm in diameter.
  • Children and Pets: Keep children and pets away from the operating pump and any water being drained.
  • Maintenance: Always disconnect the pump from the power supply before performing any maintenance or cleaning.
IPX8 Water-Resistance Level and Max Fluid Temperature 95°F

Image 2.1: The pump features IPX8 water resistance and is suitable for fluids up to 95°F.

3. Package Contents

Verify that all items are present and undamaged upon opening the package:

  • 1x TRUPOW Submersible Water Pump (Model TP-0818A)
  • 1x 25ft Hose Kit
  • 2x Hose Adapters (1" NPT and 3/4" Garden Hose)
  • 1x Instruction Manual
Multiple hose adapters and 25ft hose

Image 3.1: The pump comes with various hose adapters and a 25ft hose for versatile connections.

4. Setup Instructions

Follow these steps to prepare your pump for operation:

  1. Choose Appropriate Adapter: Select the correct hose adapter (1" NPT or 3/4" garden hose) for your water pipe or hose. Securely attach it to the pump's discharge port.
  2. Connect Hose: Attach the 25ft hose (or your own compatible hose) to the adapter. Ensure a tight connection to prevent leaks.
  3. Position the Pump: Place the pump in the area to be drained. Ensure the pump is on a stable, level surface.
  4. Submerge the Pump: Immerse the pump in the water at an angle to allow any trapped air to escape. The minimum water level for self-priming is 65mm (approximately 2.5 inches). Ensure the pump is fully submerged before plugging it in.
Three steps for pump setup: choose adapter, immerse pump, plug in

Image 4.1: Visual guide for connecting the adapter, immersing the pump, and initiating operation.

5. Operating Instructions

The TRUPOW Submersible Water Pump operates via manual plug-in/out control.

  1. Initiate Pumping: Once the pump is correctly set up and fully submerged, plug the power cord into a grounded electrical outlet. The pump will begin operating immediately.
  2. Monitor Water Level: This pump does not have an automatic float switch. It is crucial to monitor the water level to prevent dry running, which can damage the motor. The pump can remove water down to 8mm (approximately 0.3 inches).
  3. Stop Pumping: When the desired water level is reached or the pump is no longer needed, unplug the power cord from the electrical outlet to stop operation.
  4. Removing the Pump: When lifting the pump, always use the integrated handle. Do not pull the pump by its power cable.
TRUPOW pump removing water down to 1/3 inch

Image 5.1: The pump's capability to reduce water levels to a minimum residual depth.

6. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your pump.

  • Disconnect Power: Always unplug the pump from the power source before any cleaning or maintenance.
  • Clean Bottom Screen: The pump is equipped with a removable inlet strainer (bottom screen) that prevents coarse dirt from entering. Periodically remove and clean this screen to prevent clogs and maintain efficient water flow.
  • Inspect for Damage: Regularly inspect the power cord, housing, and connections for any signs of wear or damage. Do not use the pump if any damage is found.
  • Storage: When not in use, clean the pump thoroughly, drain any remaining water, and store it in a dry, frost-free location.
Removable suction base and powerful 360 degree bottom suction

Image 6.1: The removable suction base allows for easy cleaning of the inlet strainer.

7. Troubleshooting

If you encounter issues with your pump, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Pump does not startNo power supply; Overheat protection activated; Impeller jammed.Check power connection; Allow pump to cool down; Disconnect power and clear any debris from the impeller.
Pump runs but no water is dischargedHose kinked or blocked; Inlet strainer clogged; Air trapped in pump; Water level too low.Check and clear hose; Clean inlet strainer; Immerse pump at an angle to release air; Ensure water level is above 65mm.
Reduced pumping performanceInlet strainer partially clogged; Hose diameter too small or too long; Excessive vertical lift.Clean inlet strainer; Use a larger diameter or shorter hose; Reduce vertical lift if possible.
Pump stops during operationOverheat protection activated; Power interruption; Water level too low.Allow pump to cool; Check power supply; Ensure pump remains submerged.

8. Specifications

FeatureSpecification
ModelTP-0818A
Power Supply110-120V/60Hz
Horsepower1HP
Max. Delivery Rate3980 GPH
Max. Delivery Height28 FT
Min. Self-Priming Level65mm (approx. 2.5 inches)
Min. Suction Level8mm (approx. 0.3 inches)
Power Cord Length16.4 FT
Max. Particle Diameter4mm
Protection TypeIPX8
Max. Fluid Temperature95°F (35°C)
Item Weight11.75 pounds
MaterialPolypropylene, Polyvinyl Chloride
Compact size and detailed specifications of the TRUPOW pump

Image 8.1: Visual representation of the pump's compact dimensions and key technical specifications.

9. Warranty and Support

TRUPOW stands behind the quality of its products. This pump is 100% manufacturer tested to ensure a long-lasting lifespan.

For any reason you are not satisfied or require assistance, please feel free to contact us. We are committed to replying and solving your problems within 24 hours.

Contact Support:

Please refer to your purchase platform or the contact information provided at the time of purchase for the most direct support channels.

© 2025 TRUPOW. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.