1. Introduction

The Leakbee YC302 Carbon Monoxide (CO) Detector is designed to monitor carbon monoxide levels and provide audible and visual alerts in the event of dangerous concentrations. Carbon monoxide is a colorless, odorless, and tasteless gas that can be fatal when inhaled. This manual provides essential information for the proper installation, operation, and maintenance of your CO detector to ensure its effective performance and your safety.

2. Safety Information

Read all instructions carefully before installation and operation. Keep this manual for future reference. This device is intended for detecting carbon monoxide gas from various sources such as furnaces, water heaters, gas stoves, and vehicle exhaust. It is not designed to detect smoke, fire, or other gases.

2.1 Potential Sources of Carbon Monoxide

Carbon monoxide can be produced by any fuel-burning appliance or engine. Common sources include:

  • Cars left running in attached garages
  • Portable generators
  • Operating grills indoors or in garages
  • Improperly installed kitchen ranges or vents
  • Gas or wood-burning fireplaces
  • Water heater vent pipes
  • Portable kerosene or gas heaters
  • Cracked or loose furnace exchangers
Infographic listing potential sources of carbon monoxide (CO), including cars left running in attached garages, portable generators, operating grills indoors/in garages, improperly installed kitchen ranges/vents, gas or wood burning fireplaces, water heater vent pipes, portable kerosene or gas heaters, and cracked or loose furnace exchangers.

Figure 1: Potential Sources of Carbon Monoxide

2.2 Important Warnings

  • Do not paint the detector. Paint can clog the vents and interfere with sensor operation.
  • Do not block the air vents on the detector.
  • This detector requires a continuous power supply (110V-220V AC) to operate. It does not have a battery backup.
  • Regularly test the detector as described in the Maintenance section.

3. Product Overview

The Leakbee YC302 is a compact, plug-in carbon monoxide detector featuring a digital LED display and an audible alarm. Its design allows for easy integration into various environments.

Front and side view of the Leakbee YC302 Carbon Monoxide Detector with dimensions (3.74 inches x 3.74 inches x 1.57 inches). Labels for Test Area, Display, Test/Mute Button, Folding Prongs, and Air Vents are visible.

Figure 2: Detector Components and Dimensions

Front view of the Leakbee YC302 Carbon Monoxide Detector alongside icons representing its features: Digital display, Easy to Install, >=85dB Voice Alarm, Audible and Visual Alarm, CO Range 0-1000 PPM, Test/Mute Button.

Figure 3: Key Features

3.1 Key Features

  • Digital LED Display: Shows real-time carbon monoxide concentration in parts per million (PPM).
  • Audible Alarm: Emits an 85-decibel warning sound when CO levels reach dangerous thresholds.
  • Visual Alarm: Indicator lights (POWER, FAULT, ALARM) provide status at a glance.
  • Test/Mute Button: Allows for manual testing of the alarm and silencing false alarms.
  • Plug-in Design: Directly plugs into a standard 120V outlet for continuous monitoring.

4. Installation

The Leakbee YC302 Carbon Monoxide Detector is designed for simple plug-in installation.

4.1 Placement Guidelines

For optimal detection and safety, consider the following placement guidelines:

  • Install at least one CO detector on each level of your home, especially near sleeping areas.
  • Place detectors in rooms with fuel-burning appliances (e.g., kitchen, furnace room).
  • Avoid placing the detector in direct sunlight, near heating/cooling vents, or in areas with high humidity.
  • Ensure the detector is not obstructed by furniture, curtains, or other objects.
  • The plug-in design allows for flexible placement in any standard 120V outlet. The folding prongs allow for the detector to be oriented to avoid blocking the second outlet.
The Leakbee YC302 Carbon Monoxide Detector plugged into a wall outlet, demonstrating its compact design that leaves the second outlet free. An arrow indicates the folding prongs.

Figure 4: Plug-in Installation Example

Diagram illustrating recommended placement of Carbon Monoxide (CO) alarms, Natural and Propane Gas alarms, and Fire Extinguishers within a multi-story home, including bedrooms, bathrooms, living room, kitchen, garage, and basement.

Figure 5: Home Safety Product Placement Guide

4.2 Initial Power-Up

  1. Plug the detector into a standard 120V AC electrical outlet.
  2. Upon initial power-up, the detector will perform a self-test. The digital display will cycle through segments, and the alarm may sound briefly. This indicates proper functioning.
  3. Once the self-test is complete, the green POWER indicator light will illuminate, and the display will typically show "0 PPM" under normal, CO-free conditions.

5. Operating Instructions

5.1 Normal Operation

During normal operation, the green POWER indicator light will be steadily lit. The digital display will show "0 PPM" if no carbon monoxide is detected. The detector continuously monitors the air for CO.

5.2 Test Function

To test the detector, press and hold the Test/Mute Button (located on the side or front, as shown in Figure 2) for approximately 3 seconds. The alarm will sound, and the display will show a test value (e.g., "8888" or a high PPM reading). Release the button to stop the test. This confirms the alarm and display are functioning correctly.

5.3 Alarm Conditions and Responses

The detector is programmed to alarm at specific CO concentration levels and durations:

  • CO Concentration ≥ 80 PPM: The corresponding concentration will be displayed on the digital screen.
  • CO Concentration ≥ 150 PPM: A loud audible alarm (85 dB) will sound, and the red ALARM indicator light will flash.
The Leakbee YC302 Carbon Monoxide Detector displaying a CO concentration of '100 PPM' with smoke visible, indicating an active detection. Text below describes alarm outputs based on gas concentration: CO Concentration >=80ppm displays, CO Concentration >=150ppm triggers sound and light alarm.

Figure 6: CO Detection and Alarm Thresholds

The effects of carbon monoxide exposure vary with concentration and duration:

  • 100 PPM: Slight headache within 2 to 3 hours.
  • 200 PPM: Slight headache within 2 to 3 hours, loss of judgment.
  • 400 PPM: Frontal headache within 1 to 2 hours.
  • 800 PPM: Dizziness, nausea, cramps in 45 minutes; death within 2 to 3 hours.
The Leakbee YC302 Carbon Monoxide Detector displaying '8888' (test mode) with text describing the effects of various CO concentrations on human health: 100PPM (slight headache), 200PPM (slight headache, loss of judgment), 400PPM (frontal headache), 800PPM (dizziness, nausea, cramps, death).

Figure 7: Effects of CO Concentration on Health

5.4 What to Do When the Alarm Sounds

  1. Immediately move to fresh air outdoors or open all doors and windows to ventilate the area.
  2. Do a head count to check that all persons are accounted for.
  3. Do not re-enter the premises until the CO alarm has stopped and the area has been thoroughly ventilated.
  4. Call the fire department or a qualified technician to investigate the source of the carbon monoxide.
  5. If the alarm sounds again, repeat steps 1-4.

5.5 Mute Function

In the event of a nuisance alarm (e.g., from temporary, low-level CO exposure during cooking), you can press the Test/Mute Button to temporarily silence the audible alarm for a short period. The detector will continue to monitor CO levels. If CO levels remain high, the alarm will reactivate.

6. Maintenance

Regular maintenance ensures the continued reliability of your CO detector.

  • Weekly Test: Press the Test/Mute button weekly to ensure the alarm and display are functioning.
  • Monthly Cleaning: Gently vacuum or wipe the exterior of the detector, especially around the air vents, to remove dust and debris. Do not use cleaning sprays or solvents.
  • Avoid Obstructions: Ensure that nothing is blocking the air vents of the detector.

7. Troubleshooting

If your detector is not operating as expected, refer to the following common issues:

ProblemPossible CauseSolution
No display, no lightsNo powerCheck if the outlet has power. Try plugging into a different working outlet.
Display shows "ERR"Sensor fault or malfunctionUnplug the detector for 30 seconds and plug it back in. If "ERR" persists, the unit may be faulty and needs replacement.
Alarm sounds without visible CO sourceLow-level CO, dust, or humidity interferenceVentilate the area. Press the Mute button. Clean the detector. If alarms persist, investigate potential hidden CO sources.
Green POWER light off, other lights onUnit faultUnplug and replug. If the issue continues, the unit may be faulty.
Front view of the Leakbee YC302 Carbon Monoxide Detector with its digital display showing 'ERR', indicating an error or fault condition.

Figure 8: "ERR" Display Indicating a Fault

8. Specifications

FeatureSpecification
Model NumberYC302
BrandLeakbee
Power Source110V~220V AC
Alarm TypeVisual & Audible Alarm
Audible Alarm Level≥ 85 dB
CO Detection Range0-1000 PPM
Operating Humidity≤ 80%, non-condensing
MaterialPlastic
Product Dimensions (D x W x H)9.5D x 9.5W x 4H Centimetres (approx. 3.74 x 3.74 x 1.57 inches)
ColourWhite
UPC717331791124
Country of OriginChina

9. Warranty and Support

9.1 Manufacturer Warranty

This Leakbee YC302 Carbon Monoxide Detector comes with a 2-Year Manufacturer Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

9.2 Customer Support

For any questions, technical assistance, or warranty claims, please contact Leakbee customer support:

  • Email: support@yeezou.com
  • Manufacturer: Shenzhen Yeezou Technology Co., Ltd
  • Address: 15 Shunfeng Road, Baoan District, Shenzhen, 518000, China

© 2026 Leakbee. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.