Jadeshay GYAR9-A-TY

Jadeshay GYAR9-A-TY 40A 30mA WiFi Automatic Reclosing Earth Leakage Circuit Breaker User Manual

Model: GYAR9-A-TY | Brand: Jadeshay

1. Introduction

This manual provides essential information for the safe and effective installation, setup, and operation of your Jadeshay GYAR9-A-TY 40A 30mA WiFi Automatic Reclosing Earth Leakage Circuit Breaker. Please read these instructions carefully before use and retain them for future reference.

Jadeshay GYAR9-A-TY Earth Leakage Circuit Breaker in various application settings like smart homes, factories, and shopping malls.

Figure 1: Product Application - The Jadeshay GYAR9-A-TY is designed for various applications including smart homes, factories, and commercial buildings to protect against electrical leakage faults.

2. Safety Information

WARNING: Electrical installation and maintenance should only be performed by qualified personnel. Failure to follow these instructions can result in electric shock, fire, or serious injury.

  • Always disconnect power at the main circuit breaker before installing or servicing the device.
  • Ensure the device is correctly rated for your electrical system (AC 230V, 40A, 30mA).
  • Do not operate the device if it appears damaged.
  • Ensure all connections are secure and properly insulated.
  • The device is designed for indoor use in dry environments.

3. Product Overview

The Jadeshay GYAR9-A-TY is an intelligent 2-pole automatic reclosing Earth Leakage Circuit Breaker (ELCB) with WiFi connectivity, designed to enhance electrical safety and convenience. It features a digital display and supports both manual and app-based control.

Key Features:

  • Intelligent Automatic Reclosing: Automatically restores power after an unexpected trip in AUTO mode.
  • TUYA App Control: Remote operation and monitoring via the TUYA application.
  • Digital Display: 3-digit LED display shows operational status, trip count, and reclosing countdown.
  • Two Switching Modes: Manual (MANU) and Automatic (AUTO) operation.
  • LOCK Mode: Prevents accidental closing for enhanced safety during maintenance.
  • DIN Rail Installation: Standard 35mm DIN rail mounting for easy integration.
  • PC Material & IP20 Protection: Durable construction for reliable performance.

Components:

Diagram showing the components of the Jadeshay GYAR9-A-TY circuit breaker, including leakage switch, safety lock, broken code display, LED digital display, working mode selection, product number, indicator window, and operating handle.

Figure 2: Product Components - This diagram labels the key parts of the circuit breaker, including the leakage switch, safety lock, digital display, and operating handle.

  • Leakage Switch: Detects earth leakage currents.
  • Safety Lock: Prevents unintended operation.
  • Broken Code Display: Shows error codes or operational status.
  • LED Digital Display: Provides real-time information.
  • Working Mode Selection (MANU/AUTO): Switch between manual and automatic reclosing modes.
  • Operating Handle: For manual switching of the circuit breaker.
  • Indicator Window: Shows closing status (green for normal, red for fault).

4. Specifications

Product size information and technical specifications for the Jadeshay GYAR9-A-TY circuit breaker, showing dimensions and electrical parameters.

Figure 3: Product Size and Technical Specifications - This image provides detailed dimensions and electrical characteristics of the device.

ParameterValue
Model NumberGYAR9-A-TY (QJLLAVTTO-0529GJAYS99503-02)
Rated Current40 Ampere
Rated Residual Current30 mA
Working VoltageAC 230V
Working Frequency50/60Hz
Type of Circuit BreakerGFCI (AC-Type Earth Leakage)
Mounting TypeDIN-rail mounting
Protection LevelIP20
Product Dimensions11.5 x 12 x 8 cm
Item Weight304 Grams
Electrical Life10,000 times
Power Consumption≤ 1.5VA (static), ≤25VA (dynamic)

5. Installation

The Jadeshay GYAR9-A-TY is designed for standard 35mm DIN rail mounting. Ensure proper electrical safety procedures are followed during installation.

Wiring Diagram:

Product wiring diagram for the Jadeshay GYAR9-A-TY circuit breaker, showing connections for Line (L), Neutral (N), and loads, along with optional external opening and closing buttons.

Figure 4: Product Wiring Diagram - This diagram illustrates the correct electrical connections for the circuit breaker, including Line (L), Neutral (N), and load connections. It also shows connections for optional external control buttons.

  • Connect the Line (L) and Neutral (N) input wires to the top terminals as indicated.
  • Connect the load wires to the bottom terminals.
  • For automatic reclosing, an external button is not required.
  • For manual control of opening and closing, an external button is required. Use a normally open self-reset button. Other button types are not applicable.
Close-up view of the screw terminals on the Jadeshay GYAR9-A-TY circuit breaker, highlighting the connection points for electrical wiring.

Figure 5: Terminal Connections - A detailed view of the screw terminals for secure wiring.

6. Setup

Network Distribution Mode (WiFi Connection):

  1. Ensure the device is powered on.
  2. Pull out the "LOCK" latch on the device.
  3. Within 5 seconds, toggle the AUTO-MANU switch back and forth twice to activate network distribution mode.
  4. Once network distribution is activated, the red indicator light on the earth leakage circuit breaker will flash.
  5. After successful WiFi connection, the green indicator light will flash.
  6. After network distribution, set the device to AUTO mode and replace the "LOCK" latch. The device can then be used normally.

TUYA App Connection:

Download the TUYA Smart app from your mobile device's app store. Follow the in-app instructions to add and configure your Jadeshay GYAR9-A-TY device. The app allows for remote control and monitoring.

Jadeshay intelligent circuit breaker with a smartphone displaying the Tuya app interface for remote control.

Figure 6: TUYA App Integration - The device can be controlled and monitored remotely via the TUYA Smart app on your smartphone.

7. Operating Instructions

Intelligent Automatic Reclosing:

  • AUTO Mode: In this mode, if the circuit breaker trips unexpectedly, it will automatically attempt to reclose (reclosing and cycle mode). This mode supports remote operation via the app and does not require manual closing, improving efficiency.
  • MANU Mode: In this mode, if the circuit breaker trips unexpectedly, only manual opening and closing are possible. Remote control is not available. The circuit breaker needs to be manually restored after a fault.

TUYA App Control:

The TUYA app allows remote opening and closing of the circuit breaker. In case of a fault, three modes are available:

  • Normal Operation: Standard remote control.
  • Reclosing Mode (3 times): The device attempts to reclose up to 3 times. The time range for reclosing can be set in the app. After three unsuccessful reclosing attempts, automatic closing will cease, requiring manual intervention.
  • Cycle Mode (10 times): The device attempts to reclose 10 times, with each attempt lasting 10 seconds (adjustable from 5 to 200 seconds). After 10 unsuccessful attempts, only manual closing is possible.
Diagram illustrating the self-locking mode and app remote control options for the Jadeshay circuit breaker, showing normal, reclosing, and cycling modes with adjustable time settings.

Figure 7: Self-Locking Mode and App Control - This image details the various reclosing and cycle modes configurable via the app, along with the waveform definitions for AC and A type devices.

LOCK Mode:

After pressing the LOCK mode button, all closing movements are locked. This feature protects the power supply and prevents accidental contact, ensuring safety during maintenance or when the circuit needs to remain open.

8. Maintenance

Monthly Test:

It is recommended to press the "Test Monthly" button on the device at least once a month to ensure the earth leakage protection function is operating correctly. If the device does not trip when the test button is pressed, it may indicate a fault and should be inspected by a qualified electrician.

9. Troubleshooting

The LED digital display provides a 3-digit break code, indicating the number of openings and the countdown to reclosing/recovery. Refer to the app or product documentation for specific error code interpretations.

Common Issues:

  • Device not connecting to WiFi: Ensure the device is in network distribution mode (red indicator flashing) and your WiFi network is 2.4GHz. Check router settings and signal strength.
  • Device not reclosing automatically: Verify the device is set to AUTO mode. Check the app settings for reclosing and cycle modes. If multiple reclosing attempts fail, a persistent fault may be present.
  • Device trips frequently: This indicates a persistent electrical fault (e.g., earth leakage, overload). Consult a qualified electrician to diagnose and resolve the underlying issue in your electrical system.
  • Display shows an error code: Note the code and consult the TUYA app or Jadeshay support for specific troubleshooting steps.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact Jadeshay customer service through the retailer where the product was purchased or visit the official Jadeshay website. Keep your purchase receipt as proof of purchase.