NCVI AM8161

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

NCVI Heated Wearable Breast Pump AM8161 User Manual

Model: AM8161

Introduction

Thank you for choosing the NCVI Heated Wearable Breast Pump. This manual provides essential information for the safe and effective use of your new breast pump. Please read all instructions carefully before first use and retain for future reference.

The NCVI AM8161 is designed for hands-free expression, featuring 360° surround heating, hospital-grade suction up to 300mmHg, a long-lasting 2000mAh battery, and multiple modes and levels for a customizable pumping experience. Its slim, leakproof design ensures discretion and convenience.

What's in the Box

Your NCVI Heated Wearable Breast Pump package includes the following components:

  • NCVI Heated Wearable Breast Pump Motor Unit
  • Milk Collector Cup
  • Flange (28mm pre-installed)
  • Flange Inserts (19mm, 21mm, 24mm)
  • Diaphragm
  • Duckbill Valve
  • USB Charging Cable
  • Nipple Measurement Tool
  • Disposable Nursing Pads
  • Breast Milk Storage Bags
NCVI Heated Wearable Breast Pump and accessories

Image: NCVI Heated Wearable Breast Pump with included accessories, including flange inserts, milk storage bags, and a nipple measurement tool.

Setup

1. Flange Sizing

Using the provided nipple measurement tool, determine your correct flange size for optimal comfort and milk expression. The pump includes 19mm, 21mm, 24mm, and 28mm flange options.

NCVI breast pump with various flange sizes

Image: A visual representation of the NCVI breast pump with different flange sizes (19mm, 21mm, 24mm, 28mm) to ensure a perfect fit.

2. Assembly

Ensure all parts are clean and dry before assembly. Follow these steps:

  1. Attach the duckbill valve to the flange, pressing firmly until secure.
  2. Fit the diaphragm onto the flange, ensuring a tight seal.
  3. Connect the assembled flange and diaphragm to the milk collector cup.
  4. Attach the motor unit securely on top of the assembled milk collector and flange.

Video: This video demonstrates the assembly process of the NCVI Heated Wearable Breast Pump, showing how to connect the diaphragm, valve, flange, milk collector, and motor unit.

Operating Instructions

1. Power On/Off

Press and hold the power button (located at the top center of the motor unit) to turn the pump on or off. A green light will indicate the pump is active. The pump will automatically shut down after 10 minutes of inactivity.

2. Switching Modes

The NCVI AM8161 offers 4 distinct modes: Multitronic, Massage, Suck Simulate, and Express. Short press the 'M' button to cycle through these modes. Each mode is indicated by a different light pattern on the motor unit.

  • Multitronic Mode: Variable frequency for increased milk output, ideal for over-suppliers.
  • Massage Mode: Gentle stimulation to initiate milk flow and let-down.
  • Suck Simulate Mode: Mimics a baby's natural sucking rhythm for continuous milk flow.
  • Express Mode: Deep, slow suction to effectively empty the breast.

3. Adjusting Suction Levels

Use the '+' and '-' buttons to adjust the suction intensity within each mode. There are 9 adjustable levels, allowing you to find your most comfortable and effective setting.

4. Heating Function

The pump features a 360° surround heating function. Long press the 'M' button to activate or deactivate heating. The heating warms the breast evenly to 98–108°F in approximately 30 seconds, promoting milk flow and comfort. It automatically shuts off after 10 minutes.

Video: This video highlights the heating function of the NCVI Heated Wearable Breast Pump, demonstrating how gentle warmth can enhance milk output and overall comfort during pumping sessions.

Cleaning & Maintenance

Proper cleaning and maintenance are crucial for hygiene and pump longevity. Always clean parts immediately after each use.

1. Disassembly

Carefully detach the motor unit from the milk collector. Then, separate the flange, diaphragm, duckbill valve, and milk collector cup. The milk collector cup features a double-seal design that can be opened for thorough cleaning.

2. Cleaning

Rinse all washable parts (excluding the motor unit) with clean water. Wash with warm, soapy water and rinse thoroughly. All parts are BPA-free and food-grade silicone.

3. Sanitizing

Sterilize washable components by boiling or steaming for no more than 5 minutes. Ensure all components are completely dry before reassembling to prevent damage to the main unit and maintain suction power.

Video: This video illustrates the disassembly, cleaning, and sanitizing process for the NCVI Heated Wearable Breast Pump, emphasizing the ease of cleaning its few parts.

Charging

The pump is equipped with a 2000mAh rechargeable battery. Use the provided magnetic USB charging cable to charge the unit. A full charge provides up to 180 minutes of use, or approximately 8 pumping sessions. The indicator light will turn solid green when fully charged. Please power off the pump while charging.

NCVI breast pump charging and battery life

Image: The NCVI breast pump highlighting its 2000mAh battery, 180 minutes of use, and magnetic charging feature.

Troubleshooting

If you encounter issues with your NCVI breast pump, consider the following:

  • No Suction/Weak Suction: Ensure all parts are correctly assembled and securely sealed. Check that the duckbill valve is clean and not damaged. Ensure the diaphragm is properly seated.
  • No Power: Verify the pump is fully charged. Connect the magnetic USB cable and check for the charging indicator light.
  • Leaks: Confirm the flange and milk collector are correctly assembled and tightly sealed. Ensure the double-seal flange is properly positioned.
  • Discomfort during Pumping: Re-evaluate your flange size using the nipple measurement tool. Adjust suction levels to a comfortable setting. Utilize the heating function for added comfort and milk flow.

Specifications

FeatureSpecification
Model NumberAM8161
Suction RangeUp to -300mmHg (Hospital-Grade)
Battery Capacity2000mAh
Battery LifeUp to 180 minutes (approx. 8 sessions)
Modes4 (Multitronic, Massage, Suck Simulate, Express)
Suction Levels9
Heating Temperature98–108°F
MaterialPolypropylene, Silicone (BPA-Free)
Special FeaturesAdjustable Suction, Hands-Free Usage, Painless, Rechargeable, Wearable, 360° Heating, Leakproof Design

Warranty and Support

For warranty information, product support, or to purchase replacement parts, please visit the official NCVI website or contact customer service through your retailer. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.