TILSWALL W301

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

Tilswall Infrared Thermometer User Manual

Model: W301

1. Introduction

Thank you for choosing the Tilswall Infrared Thermometer, Model W301. This non-contact thermometer is designed for safe and accurate temperature measurement across a wide range of applications, from cooking and BBQ to industrial and automotive uses. It features a high-precision sensor, adjustable emissivity, and a clear LCD display for easy readings. Please read this manual thoroughly before use to ensure proper operation and safety.

Tilswall Infrared Thermometer with two AAA batteries

Figure 1: Tilswall Infrared Thermometer and included batteries.

2. Safety Information

WARNING: This device is not intended for measuring human body temperature. It is designed for industrial, culinary, and general surface temperature measurements only.

Always observe the following safety precautions when using your infrared thermometer:

  • Do not point the laser directly at eyes or indirectly off reflective surfaces. Laser radiation can cause eye damage.
  • Do not use the device near explosive gas, steam, or dust.
  • Do not immerse the unit in water or expose it to excessive moisture.
  • Keep the device out of reach of children.
  • If the device is damaged, do not operate it. Contact customer support.
Image showing the thermometer pointed at a person's forehead with a red circle and cross over it, indicating it's not for human use.

Figure 2: Important warning - Not for human temperature measurement.

3. Product Components

The Tilswall Infrared Thermometer package includes:

  • Tilswall Infrared Thermometer (x1)
  • AAA Batteries (x2)
  • User Manual (x1)
Contents of the Tilswall Infrared Thermometer package, including the thermometer, two AAA batteries, and the user manual.

Figure 3: Package contents.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment on the handle of the thermometer.
  2. Open the battery compartment cover.
  3. Insert the two AAA batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

5. Operating Instructions

5.1 Taking a Measurement

  1. Press the trigger to turn on the unit. The LCD display will illuminate.
  2. Aim the laser pointer at the center of the target surface you wish to measure.
  3. Pull and hold the trigger. The temperature reading will be displayed on the LCD.
  4. Release the trigger to hold the reading on the display. The device will automatically turn off after 30 seconds of inactivity to conserve battery life.
Hand holding the thermometer, pressing the trigger and aiming the laser at a surface, with an inset showing the LCD display with temperature reading.

Figure 4: Press and Aim for measurement.

5.2 Switching Temperature Units (℃/℉)

To switch between Celsius (℃) and Fahrenheit (℉), press the unit switch button (usually labeled ℃/℉ or indicated by an icon) on the device. The display will update accordingly.

Two images side-by-side showing the thermometer's display, one in Celsius and the other in Fahrenheit, illustrating the unit switching feature.

Figure 5: Celsius/Fahrenheit unit selection.

5.3 Adjustable Emissivity (ε)

Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. For accurate readings, adjust the emissivity setting on your thermometer to match the material being measured. The adjustable emissivity range is 0.1 to 0.99.

  1. Determine the emissivity of the object from the table below or a similar reference.
  2. Press and hold the "MODE" button for 2 seconds to enter emissivity adjustment mode.
  3. Use the "▲" (up) or "▼" (down) buttons to increase or decrease the emissivity value.
Diagram showing three steps for adjusting emissivity: 1. Determine emissivity from a table, 2. Press MODE button for 2 seconds, 3. Use up/down arrows to adjust value. An example table of common material emissivities is included.

Figure 6: Steps for adjusting emissivity and an example emissivity table.

Common Emissivity Values:

MaterialEmissivity (ε)
Water0.93
Ice0.98
Painted Surfaces0.90 - 0.98
Wood0.90
Concrete0.95
Rubber0.95
Asphalt0.95
Human Skin0.98
Polished Aluminum0.05
Oxidized Aluminum0.20 - 0.40
Polished Copper0.03
Oxidized Copper0.78
Stainless Steel0.10 - 0.80
Four images showing different materials (ice, pool water, cooking pots, pottery) with their corresponding emissivity values, demonstrating the concept of emissivity.

Figure 7: Examples of emissivity for various surfaces.

5.4 Distance-to-Spot Ratio (D:S)

The W301 has a D:S ratio of 12:1. This means that at a distance of 12 units from the target, the measurement spot diameter will be 1 unit. For example, if you are 12 inches away from the target, the measurement area will be a 1-inch circle. To ensure accurate readings, make sure the target area is larger than the spot size.

Diagram illustrating the 12:1 distance-to-spot ratio of the infrared thermometer, showing how the measurement spot size increases with distance from the target.

Figure 8: Distance-to-Spot Ratio (D:S).

5.5 Applications

The Tilswall Infrared Thermometer is suitable for a wide range of non-contact temperature measurement tasks:

  • Cooking and BBQ: Quickly check the temperature of grills, ovens, and food surfaces (e.g., pizza stones, frying oil).
  • Home Maintenance: Identify insulation issues, check HVAC vents, or monitor appliance temperatures.
  • Automotive: Measure engine components, tires, or brake temperatures.
  • Industrial: Monitor machinery, electrical panels, or manufacturing processes.
Collage of images showing the infrared thermometer being used in various applications: grilling, checking car engine temperature, measuring molten metal in a foundry, and checking pool water temperature.

Figure 9: Various applications of the infrared thermometer.

6. Maintenance

6.1 Cleaning

To clean the device, gently wipe it with a damp cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the lens is clean and free of debris for accurate readings.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the AAA batteries as described in the Setup section (4.1 Battery Installation).

7. Troubleshooting

  • No Display/Unit Not Turning On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate Readings:
    • Ensure the lens is clean.
    • Verify the emissivity setting matches the material being measured.
    • Ensure the target is within the effective distance-to-spot ratio.
    • Avoid measuring highly reflective surfaces directly; use matte tape if possible.
  • Laser Not Visible: Check if the laser function is enabled (if applicable, refer to device buttons). Ensure the environment is not too bright.

8. Specifications

FeatureSpecification
Model NumberW301
Temperature Range-50°C to 600°C (-58°F to 1112°F)
Accuracy±1.5% or ±1.5°C
Response Time0.5 seconds
Distance-to-Spot Ratio (D:S)12:1
EmissivityAdjustable (0.1 to 0.99)
Power Supply2 x AAA Batteries (included)
Auto-Off30 seconds
Display TypeLED
MaterialABS
Dimensions (L x W x H)9 x 5 x 17 cm
Weight250 grams

9. Warranty and Support

Tilswall products are manufactured to high-quality standards. For warranty information, technical support, or any questions regarding your Tilswall Infrared Thermometer, please contact our customer service team. Details can typically be found on the product packaging or the official Tilswall website.