1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your BAFOVY 3 Phase 380V Pressure Control Switch. This device is designed to automate the starting and stopping of a water pump, ensuring consistent pressure within your system. Please read this manual thoroughly before installation and use.
2. Safety Information
WARNING: This device operates with 380V, 3-phase electrical power. Improper installation or handling can result in serious injury or death. Always adhere to local electrical codes and safety regulations.
- Installation should only be performed by a qualified electrician.
- Always disconnect power to the pump and switch before performing any installation, maintenance, or troubleshooting.
- Ensure proper grounding of the electrical system.
- Do not operate the switch if it is damaged or appears to be malfunctioning.
- Keep children and unauthorized personnel away from the installation area.
3. Product Overview and Features
The BAFOVY 3 Phase 380V Pressure Control Switch is engineered for reliable and automatic control of water pump systems. Its robust design ensures stable pressure management and prevents common pump issues.

Figure 3.1: BAFOVY 3 Phase 380V Pressure Control Switch, top-front view. This image shows the overall design of the pressure control switch.
Key Features:
- Simple Control: Designed to maintain constant pressure during operation, effectively eliminating frequent on/off cycling and pressure fluctuations.
- Preventative Design: Helps to avoid pump malfunctions and ensures reliable water system operation.
- Durable Material: Constructed from strong, anti-corrosion materials for extended service life.
- Maximum Pressure: Capable of handling systems up to 80 psi.
- Automated Operation: Automatically manages pump starting and stopping to ensure consistent pressure and flow.
4. Specifications
Refer to the following specifications for detailed product information:
| Specification | Value |
|---|---|
| Operating Voltage | 380V (3 Phase) |
| Thread Size | 3/8 NPT |
| Minimum Pressure | 15 psi |
| Maximum Pressure | 80 psi |
| Working Pressure Range | 15-60 psi |
| Environmental Temperature | Up to 55 ℃ (131 ℉) |
| IP Grade | IP44 |
| Item Weight | 427 Grams |
| Power Source Type | AC/DC (3 Phase AC for 380V operation) |

Figure 4.1: Close-up of the 3/8 NPT brass pressure connection on the BAFOVY switch.
5. Setup and Installation
Proper installation is crucial for the safe and effective operation of the pressure control switch. Always ensure power is disconnected before beginning installation.
5.1 Mounting
- Select a secure, stable location for mounting the switch, away from excessive vibration or direct moisture.
- Ensure the mounting surface can support the weight of the switch and associated plumbing/wiring.
5.2 Plumbing Connection
- Connect the pressure control switch to your water system using the 3/8 NPT threaded port.
- Use appropriate thread sealant (e.g., PTFE tape) to ensure a leak-free connection.
- Tighten connections firmly but do not overtighten to avoid damaging the threads or housing.
5.3 Electrical Connection
This step must be performed by a qualified electrician.
- Ensure the main power supply to the pump system is completely disconnected and locked out.
- Open the electrical housing of the pressure switch.
- Connect the 3-phase, 380V power supply wires to the designated terminals within the switch. Refer to the internal wiring diagram if available.
- Ensure all connections are secure and properly insulated.
- Connect the ground wire to the designated ground terminal.
- Close the electrical housing securely to maintain its IP44 rating.

Figure 5.1: Underside view of the BAFOVY pressure control switch, showing electrical terminals and pressure port.
6. Operating Instructions
The BAFOVY Pressure Control Switch is designed for automatic operation. Once properly installed and powered, it will manage your pump system based on the set pressure range.
6.1 Automatic Operation
- When the system pressure drops below the lower set point (cut-in pressure), the switch will automatically activate the pump.
- When the system pressure reaches the upper set point (cut-out pressure), the switch will automatically deactivate the pump.
- The factory-set working pressure range is typically between 15-60 psi.
6.2 Pressure Adjustment (If Applicable)
Some models may feature an external adjustment screw for fine-tuning the pressure settings. If present, this screw is typically located on the top of the unit.

Figure 6.1: Top view of the BAFOVY pressure control switch, showing a potential pressure adjustment screw.
- Always disconnect power before attempting any adjustments.
- Carefully turn the adjustment screw (if present) to increase or decrease the cut-in and cut-out pressure settings.
- Make small adjustments and test the system to achieve the desired pressure range.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your pressure control switch.
- Monthly: Inspect all electrical connections for tightness and signs of corrosion. Check plumbing connections for leaks.
- Quarterly: Verify the operating pressure range. If the pump is cycling too frequently or not maintaining pressure, refer to the troubleshooting section.
- Annually: Perform a thorough inspection of the switch housing for any physical damage or wear. Ensure the area around the switch is clean and free from debris.
- Always disconnect power before performing any maintenance.
8. Troubleshooting
If you encounter issues with your pressure control switch, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power to the switch Faulty electrical connections Pressure above cut-in point Internal switch malfunction | Check main power supply and circuit breaker Inspect all wiring connections (power off) Verify system pressure Contact qualified technician |
| Pump does not stop | System leak Pressure below cut-out point Internal switch malfunction | Check for leaks in the plumbing system Verify system pressure and switch settings Contact qualified technician |
| Inconsistent pressure / Rapid cycling | Waterlogged pressure tank (if applicable) Small system leak Incorrect pressure differential setting Partially clogged pressure sensing line | Check and recharge pressure tank Inspect plumbing for minor leaks Adjust pressure differential (if adjustable) Clean or replace sensing line |
9. Warranty and Support
For warranty information or technical support, please contact BAFOVY customer service through the retailer where the product was purchased or visit the official BAFOVY website. Please have your model number (BAFOVYv2y1t5czem) and purchase date available when contacting support.