1. Introduction
This manual provides comprehensive instructions for the safe and effective use of your KAIWEETS KM601s Digital Multimeter and KET20 Silicone Multimeter Test Leads. The KM601s is a high-precision, 10000-count True RMS digital multimeter designed for a wide range of electrical measurements. Coupled with the durable and highly conductive KET20 test leads, this set offers reliable performance for both professional and DIY applications.
The KM601s features both a SMART mode for automatic measurement detection and a manual mode for specific parameter testing. Its rechargeable battery and robust design ensure convenience and longevity. The KET20 test leads are engineered for high safety and precision, featuring gold-plated probes and temperature-resistant silicone material.

Figure 1.1: KAIWEETS KM601s Digital Multimeter with KET20 Test Leads and accessories.
This image displays the complete product package, including the KM601s multimeter, its carrying case, the KET20 silicone test leads, and a charging cable. The multimeter features a large color display and clearly labeled function buttons.
2. Setup and Initial Use
2.1. Unpacking and Inspection
Carefully unpack all components and inspect them for any signs of damage. The package should contain:
- KAIWEETS KM601s Digital Multimeter
- KET20 Silicone Multimeter Test Leads (Red and Black)
- Carrying Case
- USB Charging Cable
- User Manual (this document)
2.2. Charging the Multimeter
The KM601s is equipped with a built-in 1200 mAh rechargeable lithium battery. Before first use, or when the low battery indicator appears, charge the device using the provided USB cable.
- Connect the small end of the USB charging cable to the charging port on the multimeter.
- Connect the standard USB end to a compatible USB power adapter (not included) or a computer USB port.
- The display will indicate charging status. Ensure the device is fully charged for optimal performance.

Figure 2.1: Charging the KAIWEETS KM601s Digital Multimeter.
This image shows the KAIWEETS KM601s multimeter connected to a power source via its USB charging cable, indicating the device's rechargeable battery feature.
2.3. Connecting Test Leads
The KET20 test leads are essential for making measurements. Always ensure they are securely connected to the correct input jacks on the multimeter.
- Connect the black test lead to the COM (Common) input jack.
- Connect the red test lead to the appropriate input jack based on the measurement type:
- For Voltage, Resistance, Continuity, Capacitance, Frequency, Diode, Temperature, NCV, Live Wire measurements: Connect to the VΩHz%mA input jack.
- For Current (mA/A) measurements: Connect to the 10A/250V or 600mA/250V input jack, depending on the expected current range. Refer to the multimeter's display for guidance.

Figure 2.2: KAIWEETS KM601s Multimeter with KET20 Test Leads connected.
This image illustrates the KAIWEETS KM601s multimeter with the red and black KET20 test leads properly inserted into their respective input jacks, ready for operation.
3. Operating Instructions
The KM601s offers both a convenient SMART mode and a comprehensive manual mode for various measurements.
3.1. Powering On/Off
Press the power button to turn the multimeter on. The device will automatically enter SMART mode. To turn off, press and hold the power button.
3.2. SMART Mode Operation
In SMART mode, the multimeter automatically identifies and measures AC/DC voltage, resistance, and continuity. This mode simplifies basic measurements by eliminating the need for manual range selection.
- Turn on the multimeter. It will default to SMART mode.
- Connect the test leads to the circuit or component you wish to measure.
- The multimeter will automatically detect the type of measurement and display the reading.

Figure 3.1: KAIWEETS KM601s in Smart & Manual Mode.
This image highlights the "SMART" and "AUTO FUNC" features on the KM601s display, illustrating its capability to automatically detect measurement types like voltage, resistance, and continuity.
3.3. Manual Mode Operation
For specific measurements or advanced functions, switch to manual mode by pressing the "FUNC" or "RANGE" button. Repeatedly pressing these buttons will cycle through available functions within a category.
The KM601s can accurately measure the following parameters in manual mode:
- AC/DC Voltage (V): Measures alternating and direct current voltage.
- Resistance (Ω): Measures electrical resistance.
- Continuity (Ω with buzzer): Checks for a complete circuit path.
- Current (A, mA): Measures alternating and direct current.
- Capacitance (F): Measures electrical capacitance.
- Frequency (Hz): Measures the frequency of an AC signal.
- Diodes (→|): Tests the functionality of diodes.
- Duty Cycle (%): Measures the ratio of pulse duration to period.
- Temperature (°C/°F): Measures ambient or contact temperature using a thermocouple (if included).
- NCV (Non-Contact Voltage): Detects AC voltage without direct contact.
- Live Wire Detection: Identifies live electrical wires.

Figure 3.2: KAIWEETS KM601s Digital Multimeter showing various measurement icons.
This image illustrates the wide range of measurement capabilities of the KM601s, including AC/DC Voltage, Resistance, Continuity, Diode, Capacitance, Frequency, Temperature, NCV/Live Wire, and AC/DC Current.
3.4. Special Functions
- HOLD: Press the "HOLD" button to freeze the current reading on the display. Press again to release.
- MIN/MAX/AVG: Press the "MAX/MIN" button to record minimum, maximum, and average values during a measurement session. Cycle through these values by pressing the button repeatedly.
- REL (Relative Measurement): Used to zero out the display for relative measurements.
- Auto Power-Off: The multimeter will automatically power off after a period of inactivity to conserve battery life. This feature can typically be disabled or adjusted in settings (refer to the full product manual for details).
- Analog Bar Display: Provides a visual representation of the measured value, similar to an analog meter.
- Color HD Screen: The large color LCD screen provides clear and easy-to-read measurements.

Figure 3.3: KAIWEETS KM601s with Color HD Screen.
This image showcases the vibrant and clear color HD screen of the KM601s multimeter, designed for easy readability of measurement data.
4. Maintenance and Care
4.1. Cleaning
To ensure the longevity and accuracy of your multimeter and test leads, follow these cleaning guidelines:
- Wipe the exterior of the multimeter with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the test leads are clean and free of debris, especially the probe tips and banana plugs.
- Do not immerse the multimeter in water or any liquids.
4.2. Battery Maintenance
The KM601s uses a rechargeable lithium battery. To maximize battery life:
- Recharge the battery when the low battery indicator appears.
- Avoid completely draining the battery frequently.
- If storing the multimeter for an extended period, charge it to approximately 50% capacity and recharge every few months.
4.3. Storage
When not in use, store the multimeter and test leads in the provided carrying case. Store in a cool, dry place, away from direct sunlight and extreme temperatures.
5. Troubleshooting
If you encounter issues with your KAIWEETS KM601s Digital Multimeter, consider the following common troubleshooting steps:
- No Display/Does Not Turn On:
- Ensure the battery is charged. Connect the multimeter to a USB power source and allow it to charge.
- Check if the power button is pressed and held sufficiently.
- Incorrect Readings:
- Verify that the test leads are securely connected to the correct input jacks for the desired measurement.
- Ensure the multimeter is in the correct mode (SMART or appropriate manual mode) for the measurement.
- Check the test leads for any damage or breaks.
- Ensure the component or circuit being tested is functioning correctly.
- "OL" or Overload Indication:
- This indicates that the measured value exceeds the multimeter's range for the current setting. Switch to a higher range if in manual mode, or ensure the measurement is within the device's specifications.
- No Continuity Beep:
- Ensure the multimeter is set to continuity mode.
- Check if the circuit is truly continuous.
For persistent issues or advanced troubleshooting, please refer to the detailed product manual that came with your device or contact KAIWEETS customer support.
6. Specifications
Key specifications for the KAIWEETS KM601s Digital Multimeter and KET20 Silicone Multimeter Test Leads:
| Feature | Specification |
|---|---|
| Display | Color LCD, 10000 Counts, True RMS |
| Measurement Modes | SMART Mode (Auto Voltage, Resistance, Continuity), Manual Mode |
| Measurable Parameters | AC/DC Voltage, Resistance, Continuity, Current (AC/DC), Capacitance, Frequency, Diodes, Duty Cycle, Temperature, NCV, Live Wire |
| Battery | Built-in 1200 mAh Rechargeable Lithium Battery |
| Safety Rating (Multimeter) | CAT III 1000V, CAT IV 600V |
| Test Lead Safety Rating | CAT III 1000V, CAT IV 600V, 20A |
| Test Lead Material | Temperature-Resistant Soft Silicone |
| Test Lead Probe Tip | 2mm Ultra-Fine Gold-Plated Probe |
| Test Lead Length | 48 inches (approx. 120 cm) |
| ASIN | B0F8C31ZHG |
| First Available Date | March 11, 2025 |

Figure 6.1: KET20 Test Leads highlighting safety ratings and design features.
This image details the specifications of the KET20 test leads, including their 0.7mm tip, silicone material, 4mm banana plug, and 120cm length, along with their CAT IV 600V and CAT III 1000V safety ratings.

Figure 6.2: KET20 Test Leads showcasing durability and material properties.
This image emphasizes the durability and material benefits of the KET20 test leads, such as their flexible silicone, high-purity copper wire, and gold-plated probes, designed for high safety and performance.
7. Warranty and Support
KAIWEETS is committed to providing high-quality products. For specific warranty information regarding your KM601s Digital Multimeter and KET20 Test Leads, please refer to the warranty card included with your product or visit the official KAIWEETS website.
For technical support, product inquiries, or assistance with troubleshooting, please contact KAIWEETS customer service. You can often find support contact details on the manufacturer's website or through the retailer where you purchased the product.
You can also visit the KAIWEETS Brand Store on Amazon for more information and support resources: KAIWEETS Store