1. Introduction
This manual provides comprehensive instructions for the HZVEKCRI RS485 Infrared Ray Temperature Measuring Sensor Probe Module. It covers the product's features, technical specifications, installation procedures, operational guidelines, maintenance tips, and troubleshooting information. Please read this manual thoroughly before using the device to ensure proper operation and safety.

Figure 1: HZVEKCRI RS485 Infrared Temperature Sensor Probe Module. This image displays the HZVEKCRI RS485 infrared temperature sensor probe module, featuring a cylindrical metal body with hexagonal nuts for mounting, a blue cap on the sensing end, and a cable extending from the other end.
2. Key Features
- Non-contact infrared temperature measurement.
- Industrial standard interface (RS485).
- Temperature range: 0°C to 200°C (up to 300°C maximum).
- High precision sensing core for reliable measurements.
- Durable design for industrial environments.
3. Technical Specifications
3.1. General Specifications
| Parameter | Value |
|---|---|
| Brand | HZVEKCRI |
| Model | HZVEKCRI RS485 |
| Item Weight | 1.76 ounces |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
| Assembly Required | No |
| Number of Pieces | 1 |
3.2. Performance Specifications
| Technical Parameter | Parameter Value |
|---|---|
| Temperature Measuring Range | 0°C ~ +200°C (maximum 300°C) |
| Temperature Measurement Accuracy | 1 or 1% (maximum 3°C) |
| Repetitive Measurement Accuracy | 0.5 or 0.5% (take the maximum value of 2°C) |
| Optical Resolution | 1.6:1 |
| Spectral Region | 8-14um |
| Response Time | 100ms |
| Emissivity | 0.96 |
| Output Mode | RS485/4-20mA/DC0-5V/DC0-10V |
| Power Supply | DC12~24V 1A |
| Outline Dimension | Φ24mm × 80mm |
3.3. Product Model Selection
The sensor is available in various output modes. The specific model determines the output type and supply voltage range.
| Product Model | Output Mode and Supply Voltage Range |
|---|---|
| SM8700B | RS485 bus |
| SM8700M | 4-20mA |
| SM8700V5 | DC0-5V |
| SM8700V10 | DC0-10V |
4. Setup and Installation
This section outlines the steps for properly setting up and installing your HZVEKCRI RS485 Infrared Temperature Sensor.
4.1. Safety Precautions
- Ensure the power supply is disconnected before installation or wiring.
- Verify that the power supply voltage matches the sensor's requirements (DC12-24V).
- Avoid exposing the sensor to extreme physical shock or corrosive environments.
- Do not attempt to disassemble the sensor, as this may void the warranty and cause damage.
4.2. Mounting the Sensor
- Select a suitable location for mounting the sensor, ensuring a clear line of sight to the target object for temperature measurement.
- Use the hexagonal nuts on the sensor body to securely fasten it to a mounting bracket or panel. Ensure the sensor is stable and does not vibrate.
- Position the sensor so that its optical lens is unobstructed and pointed directly at the area where temperature needs to be measured.
4.3. Wiring Instructions (RS485 Model)
For the RS485 output model (SM8700B), connect the sensor to your control system as follows:
- Power Supply: Connect the positive (+) terminal of the DC12-24V power supply to the sensor's power input, and the negative (-) terminal to the sensor's ground.
- RS485 A: Connect the RS485 A line from the sensor to the A terminal of your RS485 communication interface (e.g., PLC, DCS).
- RS485 B: Connect the RS485 B line from the sensor to the B terminal of your RS485 communication interface.
- Ensure proper polarity for all connections to prevent damage to the sensor or connected equipment.
Note: For 4-20mA, DC0-5V, or DC0-10V models, refer to the specific wiring diagrams provided with those variants.
5. Operation
Once the sensor is properly installed and wired, follow these steps for operation:
- Power On: Apply power to the sensor (DC12-24V). The sensor will typically begin taking measurements immediately.
- Data Acquisition (RS485): For the RS485 model, configure your PLC, DCS, or other control system to communicate with the sensor using the RS485 protocol. Refer to your system's documentation for specific communication settings (e.g., baud rate, data bits, stop bits, parity). The sensor will transmit temperature data via the RS485 bus.
- Monitoring: Monitor the temperature readings on your connected display or control interface. The sensor provides continuous, non-contact temperature measurements.
- Emissivity Setting: The sensor has a fixed emissivity of 0.96. For accurate measurements on surfaces with different emissivities, external compensation or calibration may be required in your control system.
6. Maintenance
Regular maintenance ensures the longevity and accuracy of your infrared temperature sensor.
- Cleaning the Lens: Periodically inspect the sensor's optical lens for dust, dirt, or debris. Gently clean the lens with a soft, lint-free cloth and a mild lens cleaning solution. Avoid abrasive materials or harsh chemicals.
- Cable Inspection: Check the sensor cable for any signs of damage, fraying, or wear. Replace damaged cables immediately to prevent electrical issues or signal loss.
- Mounting Security: Ensure the sensor remains securely mounted. Tighten any loose nuts or bolts as needed.
- Environmental Conditions: Operate the sensor within its specified environmental limits. Protect it from excessive moisture, dust, and extreme temperatures beyond its operating range.
7. Troubleshooting
This section provides solutions to common issues you might encounter with your sensor.
| Problem | Possible Cause | Solution |
|---|---|---|
| No temperature reading or incorrect data. |
|
|
| Inaccurate temperature readings. |
|
|
| Intermittent communication. |
|
|
8. Warranty Information
Specific warranty details for the HZVEKCRI RS485 Infrared Ray Temperature Measuring Sensor Probe Module are not provided in this document. Please refer to the product packaging or contact your point of purchase for warranty terms and conditions.
9. Customer Support
For technical assistance, troubleshooting beyond this manual, or inquiries regarding your HZVEKCRI product, please contact the manufacturer or your authorized distributor. Contact information may be available on the product packaging or the manufacturer's official website.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.