1. Introduction and Product Overview

This manual provides essential information for the safe and efficient operation of your Temank PowMr 10000W Split-Phase Solar Inverter, Model POW-SunSmart 10KP-F. This advanced solar energy storage inverter integrates solar energy storage, utility charging, and AC sine wave output capabilities. It features dual MPPT controllers for high efficiency and supports various battery types, including LiFePO4, Lead-Acid, and batteryless operation.

Key features include:

PowMr 10000W Split-Phase Solar Inverter
Figure 1: Front view of the PowMr 10000W Split-Phase Solar Inverter.

The inverter is designed for various off-grid backup and self-use applications, suitable for homes, cabins, RVs, trailers, and boats.

2. Safety Information

Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

PowMr Inverter 360 Degree Protection Features
Figure 2: The inverter includes multiple protection features such as short circuit, over-current, over/under voltage, overload, backfill, and over-temperature protection.

3. Product Components and What's in the Box

The PowMr 10000W Split-Phase Solar Inverter is a robust unit designed for reliable performance. Below is an overview of its main components and the contents of the packaging.

PowMr Inverter Production Overview Diagram
Figure 3: Production Overview showing the LCD screen, LED indicators, touchable keys, ON/OFF rocker switch, PV input, BAT input, Dry contact, CAN/RS485-2 port, RS485-1 port, USB-B port, Grounding Screw, AC OUT, AC IN, AC INPUT breaker, and Parallel Communication Port.

Package Contents:

4. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your solar inverter. Follow these steps carefully.

4.1 Mounting the Inverter

Mount the inverter on a sturdy, non-flammable surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for airflow.

PowMr Inverter mounted on a wall
Figure 4: The inverter should be securely mounted on a vertical surface, ensuring proper ventilation.

4.2 Wiring Connections

Before making any electrical connections, ensure all circuit breakers are in the OFF position. Observe correct polarity for all connections.

4.2.1 Battery Connections

Connect the positive and negative terminals of your 48V battery bank to the corresponding battery input terminals on the inverter. Use appropriate gauge wiring and ensure secure connections. The inverter supports various battery types, including LiFePO4 and Lead-Acid batteries.

Video 1: This video demonstrates the wiring process for the POW-SunSmart 10K inverter, including battery connections. Ensure all circuit breakers are in the OFF position before wiring.
Battery connection points on inverter
Figure 5: Close-up of the battery connection terminals on the inverter, showing positive and negative inputs.

4.2.2 PV Input Connections

The inverter features dual MPPT inputs. Connect your solar panel arrays to the PV1 and PV2 input terminals. Each input supports up to 5500W, with a maximum PV input voltage of 500Vdc and current of 22A. Ensure PV starting voltage is greater than 150V.

Dual MPPT PV Input Diagram
Figure 6: Diagram illustrating the dual MPPT PV inputs, allowing connection of solar panels with different specifications and quantities for optimized energy harvesting.
Video 2: This video provides a wiring guide for the POW-SunSmart 10K inverter, including detailed steps for connecting PV inputs to the distribution box.

4.2.3 AC Input and Output Connections

Connect the utility grid or generator to the AC input terminals. The inverter supports 120/240Vac split-phase/single-phase output. Connect your loads to the AC output terminals. Ensure all AC wiring adheres to local electrical codes and safety standards.

Split-Phase Connection Diagram
Figure 7: A detailed diagram showing the split-phase connection for the inverter, including PV input, AC input (mains/generator), battery, and AC output to loads. Note the specific wiring for L1, L2, N, and PE (ground).
Video 3: This video explains three different wiring methods for the POW-SunSmart 10K solar inverter, focusing on AC output configurations for various load requirements.

4.2.4 Grounding

Proper grounding is essential for safety. Connect the inverter's grounding terminal to a reliable earth ground. Refer to local electrical codes for grounding requirements.

4.2.5 Parallel Communication (Optional)

For parallel operation of multiple inverters (up to 6 units), connect the parallel communication cables between the inverters. This allows for capacity expansion up to 60kW.

Parallel Connection Diagram for Multiple Inverters
Figure 8: Diagram illustrating parallel connection configurations for two, three, and six inverters to achieve higher power output and different phase systems.
Video 4: This video provides a detailed guide for parallel operation of three POW-SunSmart 10KP inverters, covering wiring and configuration steps.

5. Operating Instructions

Once the inverter is installed and wired correctly, you can proceed with its operation.

5.1 Initial Power-Up

After all connections are secure and verified, turn on the battery circuit breaker, then the PV input breakers, and finally the AC input breaker. The inverter's LCD display will light up, indicating its operational status.

Video 5: This video demonstrates BMS communication protocol settings for the inverter and battery, including initial power-up and display verification.

5.2 LCD Display and Settings

The LCD display provides real-time monitoring of photovoltaic system operating data. Use the touchable keys to navigate through menus and configure settings.

LCD HD Display Screen showing real-time data
Figure 9: The LCD HD display screen provides real-time monitoring of photovoltaic system operating data, including battery voltage, output voltage, and power flow.

5.3 Charging Modes

The inverter offers four charging modes:

5.4 Time-Slot Charging/Discharging Function

The POW-SunSmart series is equipped with a time-slot charging and discharging function, allowing users to set different charging and discharging periods according to local peak and valley tariffs. This optimizes utility power and PV energy usage, potentially saving electricity costs.

Time-Slot Charging and Discharging Function Diagram
Figure 10: Diagram explaining the time-slot charging and discharging function, which allows users to optimize energy usage based on electricity tariffs.

5.5 Power Saving Mode

Enable power saving mode to conserve energy. When the load power drops below 50W, the inverter will switch off after a 5-minute delay. It will automatically restart when the load exceeds 50W.

Power Saving Mode Feature
Figure 11: Illustration of the power saving mode, which automatically turns off the inverter for low loads and restarts for higher loads.

5.6 Monitoring and Control via App

The inverter supports CAN, USB, and RS485 communication. Optional WiFi/GPRS data acquisition modules (purchased separately) allow for remote monitoring and control via the SMARTESS App, available on the App Store and Google Play.

SMARTESS App Monitoring and Control
Figure 12: The SMARTESS App allows users to monitor and control the solar inverter system remotely, providing real-time data and settings adjustments.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

Inverter Cooling Fans and Detachable Screen
Figure 13: The inverter features a detachable insect-proof screen for easy cleaning and intelligent cooling fans to prevent overheating.

7. Troubleshooting

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For complex problems, contact customer support.

8. Technical Specifications

FeatureSpecification
Rated Output Power10000W (continuous), 20000W (surge)
Rated Output Voltage120/240Vac (split phase/single phase)
Battery Voltage48Vdc (40-60Vdc range)
Max. PV Input Power11KW (5500W * 2)
Max. PV Input Voltage500Vdc
Max. PV Input Current22A
MPPT Voltage Range125-425Vdc
Max. MPPT Charging Current200A (2 * 100A)
AC Input Voltage Range90-140Vac per phase
Switch Time10ms
CommunicationCAN, USB, RS485
Item Weight59.5 pounds
Package Dimensions31 x 23 x 10 inches

9. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your product or visit the official Temank website. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, you may contact the seller Y-SOLAR directly via Amazon's messaging system or refer to the contact information provided in your product packaging.

Related Documents - POW-SunSmart 10KP-F

Preview Temank PVSC-70A/30A Solar Charge Controller User Manual
User manual for Temank PVSC-70A and PVSC-30A PWM solar charge controllers, covering features, system connection, operation, specifications, and troubleshooting for solar power systems.
Preview PowMr POW-SunSmart Series User Manual: 8K, 10K, 8KP, 10KP Hybrid Solar Inverters
Comprehensive user manual for PowMr POW-SunSmart 8K, 10K, 8KP, and 10KP all-in-one solar charge inverters. Covers installation, connection, operation, safety, maintenance, and parallel configurations for hybrid solar energy systems.
Preview PowMr POW-SunSmart 8K/10K Hybrid Solar Inverter User Manual
Comprehensive user manual for the PowMr POW-SunSmart 8K and 10K hybrid solar inverters. Covers installation, operation, safety, and maintenance for efficient solar energy management.
Preview PowMr POW-SunSmart Series User Manual: 8K, 10K, 8KP, 10KP Hybrid Solar Inverters
Comprehensive user manual for PowMr POW-SunSmart series hybrid solar charge inverters (8K, 10K, 8KP, 10KP). Covers installation, operation, safety, troubleshooting, and maintenance for efficient solar energy management in industrial and residential applications.
Preview PowMr POW-SunSmart 8K/10K User Manual
User manual for the PowMr POW-SunSmart 8K, POW-SunSmart 10K, POW-SunSmart 8KP, and POW-SunSmart 10KP all-in-one solar charge inverters. This guide provides essential safety instructions, product details, installation procedures, operation guidelines, and troubleshooting information.
Preview PowMr POW-SunSmart L3 & PL3 Series Hybrid Solar Inverter User Manual
Comprehensive user manual for PowMr POW-SunSmart L3 and PL3 Series hybrid solar inverters. Covers installation, connection, operation, safety, troubleshooting, and technical specifications for efficient solar energy management.