1. Introduction

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your DERMALOGIC Metro Head Spa Bed. Please read this manual thoroughly before use and retain it for future reference.

The DERMALOGIC Metro Head Spa Bed is a professional-grade unit designed for head spa treatments, featuring a U-shape water massage shampoo backwash unit with temperature and circulation control, advanced head therapy functions, and a comfortable massage bed.

2. Safety Information

Important Safety Precautions:

  • This product is intended for professional spa and salon use only.
  • Do not disassemble the unit if you are not a qualified professional.
  • Ensure the water basin is adequately filled before activating the water circulation function to prevent damage.
  • Verify that the power outlet and wiring are sufficient for the unit's maximum power of 2800W.
  • Always unplug the unit before cleaning or maintenance.
  • Keep children and pets away from the unit during operation.
  • Avoid spilling liquids on the control panel.

3. Product Components

The DERMALOGIC Metro Head Spa Bed includes the following main components:

  • U-Shape Water Massage Shampoo Backwash Unit with Cover Pillow
  • Massage Bed (PU Leather)
  • Control Panel for Time, Temperature, Water Circulation, Water Intensity, and LED Light
  • Technician Stool (adjustable height)
  • Water Circulation System (pump, hoses)
  • UPC certified Faucet and Shower Head
DERMALOGIC Metro Head Spa Bed, Khaki

Figure 1: Overview of the DERMALOGIC Metro Head Spa Bed in Khaki. Shows the massage bed, U-shape shampoo basin, control panel, and foot bath unit.

4. Setup and Installation

Please follow these steps carefully for proper assembly and installation. It is recommended to have two people for assembly.

4.1 Unpacking and Component Check

  1. Carefully unpack all components from the packaging.
  2. Verify that all parts listed in the packing list are present and undamaged.

Video 1: Professional Head Spa Equipment Installation Video. This video demonstrates the step-by-step assembly process for the head spa bed.

Video 2: KENZO Economy Head Spa w/ Rolling Stool. This video provides a visual guide to the assembly of a similar head spa unit, focusing on the main components and their connections.

4.2 Assembling the Bed Frame

  1. Assemble the bed frame components using the provided screws and screwdriver. Ensure all connections are secure.
  2. Attach the side panels to the bed frame.
  3. Install the base plate into the designated slots within the bed frame.
Assembled bed frame with shampoo basin

Figure 2: The assembled bed frame with the shampoo basin attached.

4.3 Installing the Shampoo Basin and Water System

  1. Carefully place the U-shape shampoo basin onto the designated area of the bed frame.
  2. Secure the basin using the four screw holes provided.
  3. Connect the water circulation pipes:
    • Connect the water circulation outlet pipe from the head basin to the red port of the water pump unit.
    • Connect the water circulation inlet pipe from the head basin to the blue port of the water pump unit.
    • Ensure all connections are tight to prevent leaks.
  4. Install the headrest and water circulation arch onto the basin, securing it with the screw fixing port.
  5. Place the mattress and cover pillow onto the bed frame.
Close-up of the U-shape shampoo basin with faucet and headrest

Figure 3: Detailed view of the U-shape shampoo basin, showing the faucet, shower head, and adjustable headrest.

5. Operating Instructions

5.1 Filling the Water Tank

  1. Ensure the water tank is filled with 1.5-2 liters of water. The water tank must be filled with 20 liters of water before it can be powered on.
  2. Use the water level indicator on the side of the unit to monitor the water level.

5.2 Control Panel Functions

Control panel of the DERMALOGIC Metro Head Spa Bed

Figure 4: The digital control panel for the head spa bed, showing controls for time, temperature, water circulation, water intensity, LED light, and power.

  • Time Control: Adjust the duration of the spa treatment.
  • Temperature Control: Set the desired water temperature. The display shows real-time temperature.
  • Water Circulation: Activates the water flow through the U-shape basin. Ensure adequate water is in the basin before activation.
  • Water Intensity: Adjusts the pressure of the water massage.
  • LED Light: Turns on/off the integrated LED lighting for ambiance.
  • Power Switch: Main power control for the unit.

5.3 Performing a Head Spa Treatment

  1. Ensure the client is comfortably positioned on the massage bed with their head in the U-shape basin.
  2. Fill the basin with water to the appropriate level.
  3. Turn on the water circulation using the control panel. Adjust intensity as desired.
  4. Set the water temperature to the client's preference (e.g., around 40°C if preheating is required).
  5. Utilize the shower head for rinsing hair.
  6. Activate the LED light function for enhanced relaxation.

Video 3: Head Spa Bed Massage Table with Footbath Japanese. This video demonstrates the usage of the head spa bed, including water circulation and shampooing.

6. Maintenance

Regular cleaning and maintenance are crucial for the longevity and hygiene of your spa bed.

6.1 After Each Use

  1. Remove Sprayer Head: Detach the sprayer head from the sprayer hose.
  2. Position Sprayer Hose: Insert the sprayer hose directly into the water circulation hole.
  3. Flush the System: Turn on the faucet to maximum water pressure. Allow water to flow through the system for 30-60 seconds.

Video 4: How to Clean Head Spa Water Circulation System. This video demonstrates the daily cleaning procedure for the water circulation system.

6.2 Weekly Cleaning Routine

  1. Prepare the Solution:
    • Plug the drain of the shampoo bowl.
    • Add 2 cups of water to the bowl.
    • Mix in 2 oz. of descaling powder.
  2. Run the Circulation:
    • Turn on the water circulation system.
    • Adjust water temperature to 46°C (114.8°F).
    • Let it run for 10 minutes.
  3. Drain the Bowl: Turn off the water circulation system and drain the dirty water.
  4. Flush the System Again: Repeat steps 1-4 of the "After Each Use" process to flush the system thoroughly.

7. Troubleshooting

ProblemPossible CauseSolution
No water circulationInsufficient water in the tank/basin; Power not connected; Pump malfunction.Ensure water levels are adequate; Check power connection; Contact support if pump is faulty.
Water not heatingHeating element malfunction; Temperature setting too low.Adjust temperature setting; Ensure water circulation is active before heating; Contact support.
Leaks from connectionsLoose pipe connections.Tighten all water pipe connections securely.
Unit not powering onPower cord unplugged; Faulty power outlet; Main power switch off.Check power cord and outlet; Ensure main power switch is on.

8. Specifications

  • Model: Metro Head Spa Bed
  • Brand: DERMALOGIC
  • Material: PU Leather, ABS basin
  • Dimensions (L x W x H): 78.8" x 26.8" x 27"
  • Item Weight: 260 pounds
  • Power: Max 2800W (verify electrical supply)
  • Features: 22 U-shape outlet holes, time/temperature control, advanced head therapy (steamer/medication function), UPC certified faucet/shower head.
  • Included Accessories: 1 Matching Technician Stool (adjustable height 16"-20"), 1 Bowl Cover Cushion Pillow.
Dimensional drawing of the DERMALOGIC Metro Head Spa Bed

Figure 5: Detailed dimensions of the head spa bed, including side and plane size profiles.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact DERMALOGIC customer service. Refer to your purchase documentation for specific warranty terms and contact details.

Customer Support: For assistance, please refer to the contact information provided at the point of purchase or visit the official DERMALOGIC website.

© 2025 DERMALOGIC. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.