1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your Ecoey Hardwired Smoke Detector, Model FJ162A. Please read this manual thoroughly before installation and retain it for future reference. This device is designed to detect smoke and alert occupants to potential fire hazards.
2. Important Safety Information
WARNING: This smoke detector is designed for residential use. It is not intended for use in non-residential buildings or for special purposes. Proper installation and regular maintenance are crucial for its effective operation.
- Do not paint the smoke detector. Paint can clog the sensing chamber and prevent the alarm from operating correctly.
- Test the smoke detector weekly to ensure proper function.
- Replace the 9V backup battery at least once a year, or immediately when the low battery warning sounds.
- This device must be installed by a qualified electrician in accordance with all local electrical codes.
- Do not disconnect the AC power or remove the battery unless performing maintenance or replacement.
- In case of an alarm, evacuate the premises immediately and call emergency services.
3. Package Contents
Verify that all items are present in your package:
- Ecoey Hardwired Smoke Detector (FJ162A)
- Hardwire connector
- 9V Backup Battery
- Mounting Plate
- Screws and Wall Anchors
- User Manual

Image: Contents of the Ecoey FJ162A smoke detector package, including the detector unit, mounting plate, wiring harness, 9V battery, and instruction manual.
4. Product Overview
4.1 Key Features
- 10-Year Sensor Life: Equipped with a photoelectric sensor designed for a decade of reliable smoke detection.
- Hardwired with 9V Backup Battery: Ensures continuous operation even during power outages.
- Interconnectable: Up to 12 Ecoey smoke alarms (and 6 combo smoke/CO detectors) can be interconnected, so when one alarm sounds, all connected units will activate.
- Fast Detection: Unique flared smoke inlet design allows for quicker smoke entry and detection.
- Flame-Retardant Material: Constructed with a 2mm shell resistant to high temperatures (up to 230°F).
- Test/Silence Button: Enlarged and easily accessible for weekly testing and silencing nuisance alarms.
- Junction Box Compatibility: 144mm (5.7") mounting plate fits most standard electrician boxes.
4.2 Components
The Ecoey FJ162A smoke detector consists of the main unit, a mounting plate, and a wiring harness.

Image: Front view of the Ecoey FJ162A smoke detector, highlighting its hardwired interconnected feature and model number.

Image: Close-up of the Ecoey smoke detector on a wall, indicating its 10-year sensor life with a green LED light.
5. Installation
IMPORTANT: Before installation, ensure the power to the circuit where the smoke detector will be installed is turned OFF at the main fuse or circuit breaker panel.
5.1 Choosing a Location
- Install smoke detectors on every level of your home, including basements and attics.
- Place detectors inside and outside sleeping areas.
- Avoid installing near windows, doors, or areas with high airflow, which can interfere with smoke detection.
- Keep detectors away from cooking appliances, heating vents, and bathrooms with showers to prevent nuisance alarms.

Image: Depicts various suitable locations for smoke detector installation, including living rooms, offices, bedrooms, and kitchens.
5.2 Wiring Instructions
- Turn off the AC power at the circuit breaker.
- Connect the wiring harness to your household wiring:
- Black wire: Connect to the hot (live) wire from the AC power supply.
- White wire: Connect to the neutral wire from the AC power supply.
- Red wire: Connect to the interconnect wire for multi-unit synchronization. If not interconnecting, cap this wire with a wire nut.
- Ensure all connections are secure using wire nuts.

Image: Underside view of the smoke detector revealing the hardwired connections (black, white, red wires) and the compartment for the 9V backup battery.
5.3 Mounting the Detector
- Attach the mounting plate to the electrical box using the provided screws. The 144mm (5.7") diameter plate is designed for most standard junction boxes.
- Insert the 9V backup battery into the battery compartment of the smoke detector. Ensure correct polarity.
- Connect the wiring harness from the ceiling to the back of the smoke detector unit.
- Align the smoke detector with the mounting plate and rotate it clockwise until it locks securely into place.

Image: Diagram showing the dimensions of the smoke detector and its mounting plate, illustrating compatibility with various junction box types.

Image: A series of images demonstrating the installation process, including a person connecting wires, testing a single unit, and testing multiple interconnected units.

Image: Illustrates rotating the detector counterclockwise to mount, pressing the test button, and showing interconnected units beeping together.
5.4 Interconnection (Optional)
If you are installing multiple Ecoey hardwired smoke detectors, connect the red interconnect wires between all units. When one interconnected unit detects smoke, all units will sound an alarm. A maximum of 12 smoke alarms and 6 combo smoke/CO detectors can be interconnected.

Image: An architectural diagram showing multiple smoke detectors interconnected throughout a multi-story home, providing whole-home coverage.
6. Operating Instructions
6.1 Power-Up
After installation and restoring AC power, the green LED indicator on the detector should illuminate, indicating it is receiving power. The unit will perform a self-test.

Image: Illustrates the smoke detector functioning with both AC power and its 9V backup battery, ensuring operation during power outages.
6.2 Testing the Detector
Test your smoke detector weekly to ensure it is functioning correctly.
- Press and hold the large "TEST" button on the front of the detector for approximately 5 seconds.
- The alarm will sound a loud, pulsating signal. If interconnected, all units will sound.
- Release the button. The alarm should stop.
- If the alarm does not sound, refer to the Troubleshooting section.
6.3 Silencing Nuisance Alarms
If a non-emergency alarm occurs (e.g., from cooking smoke), press the "TEST/SILENCE" button for approximately 5 seconds to temporarily silence the alarm. The detector will enter a temporary silence mode for a period (typically 10 minutes), after which it will reset. If smoke is still present, the alarm will reactivate.

Image: A couple cooking in a kitchen with an Ecoey smoke detector mounted on the wall, illustrating its ability to reduce annoying false alarms.
6.4 Low Battery Warning
When the 9V backup battery is low, the detector will chirp approximately once every 30-60 seconds. This indicates that the battery needs to be replaced immediately. You can press the "TEST/SILENCE" button to enter a 10-hour "Do Not Disturb" mode for the low battery warning, allowing you to replace the battery at a more convenient time.

Image: Shows a person sleeping peacefully while a smoke detector on the wall indicates a low battery warning, which can be muted for 10 hours.
7. Maintenance
7.1 Battery Replacement
The 9V backup battery should be replaced at least once a year, or immediately when the low battery warning chirp sounds.
- Turn off the AC power to the smoke detector at the circuit breaker.
- Rotate the detector counter-clockwise to detach it from the mounting plate.
- Open the battery compartment and remove the old 9V battery.
- Insert a new 9V battery, ensuring correct polarity.
- Close the battery compartment.
- Reattach the detector to the mounting plate by rotating it clockwise until it locks.
- Restore AC power and test the detector.
7.2 Cleaning Your Smoke Detector
Clean your smoke detector at least once a month to remove dust and debris that could interfere with its operation.
- Gently vacuum the exterior of the detector using a soft brush attachment.
- Do not use cleaning solvents or wet cloths, as these can damage the unit.
- Do not paint the detector.

Image: Close-up view of the smoke detector's perforated casing, designed to block the entry of insects and dust while allowing smoke to enter.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Alarm sounds intermittently or chirps every 30-60 seconds. | Low 9V backup battery. | Replace the 9V backup battery immediately. You can use the "Do Not Disturb" mode for 10 hours by pressing the test button. |
| Alarm sounds without visible smoke or fire. | Nuisance alarm (e.g., cooking smoke, steam), dust/debris in sensor, high humidity. | Press the "TEST/SILENCE" button to silence. Ventilate the area. Clean the detector as per Maintenance section. Relocate if consistently triggered by non-fire sources. |
| Alarm does not sound during test. | No AC power, dead 9V backup battery, faulty unit. | Check circuit breaker. Replace 9V battery. Ensure wiring is correct. If issues persist, the unit may be faulty and require replacement. |
| Green LED is off. | No AC power. | Check circuit breaker and wiring connections. |
9. Specifications
- Model: FJ162A
- Power Source: Hardwired (AC 120V) with 9V DC backup battery
- Sensor Type: Photoelectric
- Alarm Loudness: 85 dB at 10 feet
- Operating Temperature: 40°F (4.4°C) to 100°F (37.8°C)
- Operating Humidity: 10-95% RH non-condensing
- Dimensions: 5.7" (Diameter) x 1.5" (Depth)
- Interconnection: Up to 12 Ecoey smoke alarms + 6 combo smoke/CO detectors
- Material: ABS (Flame-retardant)
10. Warranty and Support
The Ecoey Hardwired Smoke Detector Model FJ162A comes with a three-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, accidents, unauthorized modifications, or improper installation.