1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the CISA 604 Series Door Closer. Designed for effective and reliable door closure, this model is suitable for doors weighing up to 85 kg and up to 1100 mm wide. Please read these instructions carefully before installation and use to ensure proper function and safety.

Image 1.1: The CISA 604 Series Door Closer in dark brown finish, showing the main body and articulated arm.
2. Safety Information
- Ensure all installation steps are followed precisely to prevent injury or damage to the door closer or door.
- Do not attempt to modify the door closer. Unauthorized modifications can compromise safety and performance.
- Keep hands and fingers clear of moving parts during operation and adjustment.
- This product is designed for doors up to 85 kg and 1100 mm wide. Using it on heavier or wider doors may result in malfunction or damage.
- Always use appropriate tools and personal protective equipment during installation.
3. Package Contents
Verify that all components are present before beginning installation:
- CISA 604 Series Door Closer Unit
- Articulated Arm Assembly
- Fixing Screws (various sizes for different mounting surfaces)
- Mounting Template
- Instruction Sheet (this document)
4. Setup (Installation)
The CISA 604 Series Door Closer can be surface-mounted on left or right-hand doors, for both pull-side and push-side applications. Refer to the included mounting template for precise hole drilling.
4.1. Pre-Installation Steps
- Determine the door's swing direction (left or right) and whether the closer will be mounted on the pull side (hinge side) or push side (opposite hinge side).
- Clean the mounting surface on the door and frame.
- Position the mounting template according to your chosen installation type and mark the drilling points accurately.
4.2. Mounting the Closer Body
- Drill pilot holes at the marked positions.
- Secure the main body of the door closer to the door frame or door using the provided fixing screws. Ensure it is level and firmly attached.
4.3. Installing the Arm Assembly
- Attach the main arm to the closer's spindle.
- Attach the forearm to the door frame or door, ensuring the correct angle as indicated in the template for optimal operation.
- Connect the main arm and forearm using the connecting screw.

Image 4.1: Detailed technical drawing of the CISA 604 Series Door Closer, illustrating dimensions and mounting hole positions for accurate installation.
5. Operating Instructions (Adjustments)
The CISA 604 Series Door Closer features independent adjustments for closing speed and final strike, allowing precise control over door movement.
5.1. Adjusting Closing Speed
The closing speed is regulated by a valve located on the side of the closer body. This valve controls the speed of the door from its fully open position until approximately 15 degrees from the closed position.
- To increase closing speed, turn the adjustment screw clockwise (usually marked 'S' or '1').
- To decrease closing speed, turn the adjustment screw counter-clockwise.
5.2. Adjusting Final Strike (Latching Speed)
The final strike, or latching speed, controls the door's speed for the last 15 degrees of closure, ensuring it latches securely without slamming. This is regulated by a separate valve.
- To increase latching speed, turn the adjustment screw clockwise (usually marked 'L' or '2').
- To decrease latching speed, turn the adjustment screw counter-clockwise.
Make small adjustments and test the door's closing action after each adjustment. Avoid over-tightening the screws.

Image 5.1: Diagram showing the two adjustment sectors: the green sector for overall closing speed (up to 80 degrees) and the red sector for final strike speed (the last 15 degrees).
6. Maintenance
The CISA 604 Series Door Closer is designed for minimal maintenance. However, periodic checks can ensure its longevity and optimal performance.
- Annual Inspection: Check all mounting screws for tightness. Re-tighten if necessary.
- Arm Assembly: Inspect the articulated arm for any signs of wear or damage. Ensure all pivot points move freely.
- Cleaning: Wipe the closer body with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners.
- Functionality Test: Periodically test the door's closing and latching speed to ensure it operates as desired. Readjust if needed.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Door closes too fast/slow | Closing speed or latching speed adjustment incorrect. | Adjust the appropriate speed valve (refer to Section 5). |
| Door does not latch properly | Latching speed too slow or arm assembly misaligned. | Increase latching speed. Check arm alignment and ensure all screws are tight. |
| Door closer leaks oil | Internal seal damage or extreme temperature fluctuations. | Contact customer support for assistance. Do not attempt to repair. |
| Door closer makes excessive noise | Loose mounting screws or worn arm components. | Check and tighten all mounting screws. Inspect arm assembly for wear. |
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | 60460 |
| Force Adjustment | EN 2-4 (Adjustable) |
| Max Door Weight | 85 kg |
| Max Door Width | 1100 mm |
| Installation Type | Surface-mounted |
| Material | Metal |
| Color | Dark Brown |
| Product Dimensions | 7.09"L x 1.57"W x 2.36"H (180 x 40 x 60 mm) |
| Item Weight | 1.54 kg (3.39 pounds) |
| Standard Met | EN 2-4 |
9. Warranty and Support
CISA products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official CISA website. For technical support, replacement parts, or further assistance, please contact your local CISA distributor or customer service.
For more information, visit the official CISA website.