Cisa 60460

CISA 604 Series Door Closer Instruction Manual

Model: 60460

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the CISA 604 Series Door Closer. Designed for effective and reliable door closure, this model is suitable for doors weighing up to 85 kg and up to 1100 mm wide. Please read these instructions carefully before installation and use to ensure proper function and safety.

CISA 604 Series Door Closer, dark brown finish

Image 1.1: The CISA 604 Series Door Closer in dark brown finish, showing the main body and articulated arm.

2. Safety Information

  • Ensure all installation steps are followed precisely to prevent injury or damage to the door closer or door.
  • Do not attempt to modify the door closer. Unauthorized modifications can compromise safety and performance.
  • Keep hands and fingers clear of moving parts during operation and adjustment.
  • This product is designed for doors up to 85 kg and 1100 mm wide. Using it on heavier or wider doors may result in malfunction or damage.
  • Always use appropriate tools and personal protective equipment during installation.

3. Package Contents

Verify that all components are present before beginning installation:

  • CISA 604 Series Door Closer Unit
  • Articulated Arm Assembly
  • Fixing Screws (various sizes for different mounting surfaces)
  • Mounting Template
  • Instruction Sheet (this document)

4. Setup (Installation)

The CISA 604 Series Door Closer can be surface-mounted on left or right-hand doors, for both pull-side and push-side applications. Refer to the included mounting template for precise hole drilling.

4.1. Pre-Installation Steps

  1. Determine the door's swing direction (left or right) and whether the closer will be mounted on the pull side (hinge side) or push side (opposite hinge side).
  2. Clean the mounting surface on the door and frame.
  3. Position the mounting template according to your chosen installation type and mark the drilling points accurately.

4.2. Mounting the Closer Body

  1. Drill pilot holes at the marked positions.
  2. Secure the main body of the door closer to the door frame or door using the provided fixing screws. Ensure it is level and firmly attached.

4.3. Installing the Arm Assembly

  1. Attach the main arm to the closer's spindle.
  2. Attach the forearm to the door frame or door, ensuring the correct angle as indicated in the template for optimal operation.
  3. Connect the main arm and forearm using the connecting screw.
Diagram showing CISA 604 Series Door Closer dimensions and mounting points

Image 4.1: Detailed technical drawing of the CISA 604 Series Door Closer, illustrating dimensions and mounting hole positions for accurate installation.

5. Operating Instructions (Adjustments)

The CISA 604 Series Door Closer features independent adjustments for closing speed and final strike, allowing precise control over door movement.

5.1. Adjusting Closing Speed

The closing speed is regulated by a valve located on the side of the closer body. This valve controls the speed of the door from its fully open position until approximately 15 degrees from the closed position.

  • To increase closing speed, turn the adjustment screw clockwise (usually marked 'S' or '1').
  • To decrease closing speed, turn the adjustment screw counter-clockwise.

5.2. Adjusting Final Strike (Latching Speed)

The final strike, or latching speed, controls the door's speed for the last 15 degrees of closure, ensuring it latches securely without slamming. This is regulated by a separate valve.

  • To increase latching speed, turn the adjustment screw clockwise (usually marked 'L' or '2').
  • To decrease latching speed, turn the adjustment screw counter-clockwise.

Make small adjustments and test the door's closing action after each adjustment. Avoid over-tightening the screws.

Diagram illustrating closing speed and final strike adjustment sectors

Image 5.1: Diagram showing the two adjustment sectors: the green sector for overall closing speed (up to 80 degrees) and the red sector for final strike speed (the last 15 degrees).

6. Maintenance

The CISA 604 Series Door Closer is designed for minimal maintenance. However, periodic checks can ensure its longevity and optimal performance.

  • Annual Inspection: Check all mounting screws for tightness. Re-tighten if necessary.
  • Arm Assembly: Inspect the articulated arm for any signs of wear or damage. Ensure all pivot points move freely.
  • Cleaning: Wipe the closer body with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners.
  • Functionality Test: Periodically test the door's closing and latching speed to ensure it operates as desired. Readjust if needed.

7. Troubleshooting

ProblemPossible CauseSolution
Door closes too fast/slowClosing speed or latching speed adjustment incorrect.Adjust the appropriate speed valve (refer to Section 5).
Door does not latch properlyLatching speed too slow or arm assembly misaligned.Increase latching speed. Check arm alignment and ensure all screws are tight.
Door closer leaks oilInternal seal damage or extreme temperature fluctuations.Contact customer support for assistance. Do not attempt to repair.
Door closer makes excessive noiseLoose mounting screws or worn arm components.Check and tighten all mounting screws. Inspect arm assembly for wear.

8. Specifications

FeatureSpecification
Model Number60460
Force AdjustmentEN 2-4 (Adjustable)
Max Door Weight85 kg
Max Door Width1100 mm
Installation TypeSurface-mounted
MaterialMetal
ColorDark Brown
Product Dimensions7.09"L x 1.57"W x 2.36"H (180 x 40 x 60 mm)
Item Weight1.54 kg (3.39 pounds)
Standard MetEN 2-4

9. Warranty and Support

CISA products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official CISA website. For technical support, replacement parts, or further assistance, please contact your local CISA distributor or customer service.

For more information, visit the official CISA website.

Related Documents - 60460

Preview CISA Electric Strikes Cover Installation Guide
Instruction sheet for CISA electric strikes covers (Art. 06A98120.XX), detailing installation configurations and mounting procedures for various door edge types. Includes guidance on selecting appropriate plates and screws.
Preview CISA 06A98910 Adapter for Fast Access Devices Retrofit - Installation Guide
This document provides installation instructions for the CISA 06A98910 Adapter for Fast Access Devices Retrofit. It covers assembly, cutting specifications, and final checks for various door configurations.
Preview CISA ALPHA PUSH RIM Series Panic Exit Device - Installation Guide
Comprehensive installation guide for the CISA ALPHA PUSH RIM Series Panic Exit Device, covering template placement, hand changes, mechanism assembly, bar installation, cover fitting, striker mounting, accessory installation, and final checks. Includes technical specifications and conformity certificates.
Preview CISA Round Cylinder Outside Access Device Installation Instructions (Art. 06A98900)
Official installation instructions for the CISA Round Cylinder Outside Access Device (Art. 06A98900) by Allegion. Includes assembly steps, part configurations, and technical details for installers.
Preview CISA Hold Open Device Installation and Configuration Guide
This document provides installation and configuration instructions for the CISA Hold Open Device (Part Number 07A65.5X.0.XX). It covers modular cover removal, setting the hand for push rim versions, and enabling the hold open mode. Includes part numbers and configuration details.
Preview CISA ALPHA TOUCH RIM Panic Exit Device Installation Guide & Specifications
Comprehensive installation guide, technical specifications, and compliance information for the CISA ALPHA TOUCH RIM series panic exit devices (models 5M801, 5M811, 5M816). Includes diagrams and part numbers.