CVFBETVFE-48MP4KHDMITYPE-CB

User Manual for Generic 3.5X-180X Trinocular Stereo Microscope

Model: CVFBETVFE-48MP4KHDMITYPE-CB

Introduction

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your Generic 3.5X-180X Trinocular Stereo Microscope. Designed for precision observation and imaging, this microscope is equipped with a high-resolution 48MP 4K HDMI Type-C B camera, making it ideal for PCB repair, industrial inspection, and educational purposes. Please read this manual thoroughly before using the microscope to ensure proper functionality and longevity.

Safety Information

  • Always handle the microscope with care to prevent damage to optical and mechanical components.
  • Ensure the microscope is placed on a stable, level surface to prevent tipping.
  • Disconnect the power supply before cleaning or performing any maintenance.
  • Do not expose the microscope to direct sunlight, high temperatures, or excessive humidity.
  • Avoid touching optical surfaces with bare hands. Use a lens cleaning cloth.

Package Contents

Verify that all components listed below are present in your package:

  • Trinocular Stereo Microscope Head
  • Sliding Double Boom Arm Stand with Base
  • WF10X/20 Eyepieces (Pair)
  • WF20X/10 Eyepieces (Pair)
  • 0.7X-4.5X Objective Lens (Integrated)
  • 48MP 4K HDMI Type-C B Video Camera
  • 144 LED Ring Light with Power Adapter
  • 0.5X Adapter Objective
  • 0.7X Auxiliary Objective
  • 2.0X Auxiliary Objective
  • 0.35X Adapter Objective
  • 0.75X Auxiliary Objective
  • Protection Glass
  • Power Cable for Camera
  • HDMI Cable
  • USB Cable
  • Silicone Repair Mat
Complete set of Generic Trinocular Stereo Microscope components including microscope head, boom arm stand, eyepieces, camera, LED ring light, and various auxiliary lenses.

Figure 1: Overview of the microscope system and its included accessories.

Setup

1. Assembling the Boom Arm Stand

  1. Place the heavy base on a stable workbench.
  2. Insert the vertical pillar (380mm high, Ø32mm diameter) into the designated hole on the base and secure it firmly.
  3. Attach the horizontal moving arm (235mm travel) to the vertical pillar. Ensure it can slide smoothly and be locked into position.
  4. Mount the focusing holder (76mm diameter) onto the horizontal arm. This holder will secure the microscope head.

2. Mounting the Microscope Head

  1. Carefully insert the trinocular stereo microscope head into the focusing holder. The head mounting size is 3" (76mm) diameter.
  2. Secure the head using the set screw on the focusing holder, ensuring it is stable but not overtightened.
  3. Insert the WF10X/20 eyepieces into the two eyepiece tubes on the microscope head. For higher magnification, use the WF20X/10 eyepieces.

3. Connecting the Camera and Illumination

  1. Attach the 48MP 4K HDMI Type-C B video camera to the trinocular port (23mm photo port) on the microscope head. You may need the 1x adapter lens for proper focus.
  2. Connect the camera to a display (monitor/TV) via the HDMI cable for 4K output, or to a computer via the USB cable for image/video capture and software control.
  3. Mount the 144 LED ring light onto the objective lens housing. The accessory mounting size is 1-7/8" (48mm female thread) diameter.
  4. Connect the LED ring light to its power adapter and plug it into a power outlet (100-240V, 50-60HZ).

Operating Instructions

1. Powering On and Illumination

  1. Ensure all connections are secure.
  2. Turn on the power switch for the LED ring light.
  3. Adjust the brightness of the LED ring light using the variable intensity control knob. The brightness is 0-100% adjustable.
  4. If using the camera, power on the camera and the connected display.

2. Adjusting Magnification and Focus

  1. Place the specimen on the working stage beneath the objective lens.
  2. Adjust the height of the microscope head using the focusing holder's coarse adjustment knob until the specimen is roughly in focus.
  3. Use the zoom knob on the microscope head to change the magnification (7X to 45X continuous zoom with standard objective).
  4. For finer focus, use the fine adjustment knob on the focusing holder.
  5. To change the overall magnification range, attach the auxiliary objective lenses (e.g., 0.5x for 3.5X-45X, 2.0x for 7X-90X). Ensure the microscope is refocused after changing auxiliary lenses.

3. Adjusting Interpupillary Distance and Diopter

  1. While looking through the eyepieces, adjust the interpupillary distance by moving the eyepiece tubes closer or further apart until you see a single, clear circular field of view. The adjustable range is 2-1/8" to 3" (54-76mm).
  2. If one eye appears out of focus, adjust the diopter ring on the left eyepiece until both eyes are in sharp focus.

4. Using the 48MP 4K HDMI Type-C B Camera

  1. Once connected to an HDMI display, the camera will output a live 4K video feed.
  2. Use the buttons on the camera unit or a connected USB mouse (if supported by the camera model) to navigate the on-screen display (OSD) menu.
  3. From the OSD, you can adjust settings such as exposure, white balance, color, and capture images or record videos.
  4. When connected via USB to a computer, use compatible microscopy software to view the live feed, capture images (Picture Pixel: 9280X5220 48M Pixel), and record videos (Video Frame rate: 4K(4:3)@24fps/2K@30fps/1080P@60fps).
  5. The camera features auto color setting and auto/one-button white balance for optimal image quality.

Maintenance

1. Cleaning Optical Components

  • Use a soft brush or compressed air to remove dust from lenses and eyepieces.
  • For smudges or fingerprints, use a specialized lens cleaning solution and a clean, soft lens cleaning cloth. Apply solution to the cloth, not directly to the lens.
  • Clean eyepieces and objectives gently in a circular motion from the center outwards.

2. General Care

  • Keep the microscope covered with a dust cover when not in use.
  • Store the microscope in a dry, cool place, away from direct sunlight and corrosive chemicals.
  • Regularly check and tighten any loose screws on the stand and microscope body.
  • Avoid disassembling the microscope head or objective lenses, as this can affect optical alignment.

Troubleshooting

ProblemPossible CauseSolution
No image visible through eyepieces.Eyepiece caps on, objective not aligned, focus too far off, illumination off.Remove caps, rotate objective turret until it clicks into place, adjust focus, turn on LED ring light.
Image is blurry or out of focus.Incorrect focus adjustment, dirty lenses, incorrect working distance.Adjust coarse and fine focus knobs. Clean lenses. Ensure specimen is within working distance (e.g., 100mm for 7X-45X).
Camera image is black or distorted.Camera not powered, HDMI/USB cable loose, incorrect camera settings (exposure/white balance).Check camera power, re-seat cables, adjust camera settings via OSD or software.
LED ring light not turning on.Power adapter not connected, faulty adapter, LED bulb failure.Check power connection, try a different outlet, contact support if light remains off.
Cannot achieve desired magnification range.Incorrect auxiliary objective used or not installed.Ensure the correct auxiliary objective (e.g., 0.5x, 2.0x) is properly screwed onto the main objective.

Specifications

Microscope System

  • Head: 45-degree inclined 360-degree swiveling trinocular simul-focal
  • Eyepiece: 30mm super widefield high-eyepoint WF10X/20, WF20X/10
  • Objective: 0.7-4.5X (integrated zoom)
  • Zoom Ratio: 6.5:1
  • Trinocular Port: 23mm photo port
  • Interpupillary Distance: 2-1/8" to 3" (54-76mm)
  • Field of View: 1-1/4" (33mm)
  • Working Distance:
    • 7X-45X (Standard): 100mm
    • With 0.5x Auxiliary Lens: 3.5X-45X (165mm)
    • With 2.0x Auxiliary Lens: 7X-90X (40mm)
  • Head Mounting Size: 3" (76mm) diameter
  • Accessory Mounting Size: 1-7/8" (48mm female thread) diameter

Boom Arm Stand

  • Vertical Pillar Height: 380mm
  • Vertical Pillar Diameter: Ø32mm
  • Horizontal Moving Range: 235mm
  • Base Size: 210x260x40mm
  • Focusing Holder: Steel Gears, Standard Size (76mm diameter)

144 LED Ring Light

  • LED Count: 144 bright white LED bulbs
  • Life Expectancy: 100,000 hours
  • Illumination: Intense and focused shadow-free
  • Brightness Control: 0-100% Adjustable, variable intensity
  • Power Input: 100-240V, 50-60HZ
  • Suit for Lens Diameter: 30mm-160mm

48MP 4K HDMI Type-C B Camera

  • Picture Pixel: 9280X5220 (48M Pixel)
  • Video Frame Rate: 4K(4:3)@24fps / 2K@30fps / 1080P@60fps
  • CMOS Sensor: 1/2.33 inch
  • CMOS Pixel Size: 1.33um x 1.33um
  • Color Setting: Auto
  • White Balance: Auto/one button

General Product Information

  • Model Number: CVFBETVFE-48MP4KHDMITYPE-CB
  • Item Weight: 11.02 pounds
  • Package Dimensions: 1.18 x 0.79 x 0.39 inches
  • Manufacturer: Generic
  • Country of Origin: China

Support

For any questions, technical assistance, or support regarding your microscope, please contact our customer service. We are committed to customer satisfaction and strive to answer your questions promptly within 24 hours.

Please refer to your purchase documentation or the seller's contact information for specific support channels.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.