Temtop PMD371 & Airing2000 Bundle

Temtop PMD371 & Airing2000 Professional Air Quality Monitoring Bundle User Manual

Model: PMD371 & Airing2000 | Brand: Temtop

1. Introduction

This user manual provides detailed instructions for the operation and maintenance of the Temtop PMD371 and Airing2000 Professional Air Quality Monitoring Bundle. This bundle offers a comprehensive solution for precise particle and air quality monitoring in various environments, including laboratories, cleanrooms, and field applications. The PMD371 is designed for detailed particle detection and environmental monitoring, while the Airing2000 extends capabilities with advanced particulate and formaldehyde detection. Please read this manual thoroughly before using the devices to ensure proper function and safety.

2. Safety Information

3. Package Contents

Verify that all items are present in the package:

4. Product Overview

Temtop PMD371 and Airing2000 devices side-by-side

Image: The Temtop PMD371 (right) and Airing2000 (left) air quality monitors, showcasing their distinct designs and displays.

Temtop PMD371 Particle Counter front view

Image: Front view of the Temtop PMD371 Particle Counter, highlighting its display and control buttons.

Temtop Airing2000 Particulate Monitor front view

Image: Front view of the Temtop Airing2000 Particulate Monitor, showing its ergonomic design and display.

4.1 Temtop PMD371 Particle Counter

The PMD371 is a precision instrument designed for multi-size particle detection and environmental monitoring. It features a robust all-metal construction for durability and reliable data collection.

Temtop PMD371 showing all-metal construction

Image: The Temtop PMD371 highlighting its durable all-metal casing, ensuring robust performance.

Temtop PMD371 dimensions and weight

Image: The Temtop PMD371 illustrating its compact size (170 x 110 x 48 mm) and lightweight design (1.76 lbs), emphasizing its portability.

4.2 Temtop Airing2000 Particulate Monitor

The Airing2000 is designed for comprehensive field monitoring, providing accurate measurements of PM2.5, PM10, TSP, temperature, humidity, and formaldehyde.

Temtop Airing2000 with features listed

Image: The Temtop Airing2000 showcasing its enterprise-grade precision, industrial-grade pumping sensor, comprehensive monitoring, instant data access, user-friendly operation, and portable design.

Temtop Airing2000 comprehensive monitoring capabilities

Image: The Temtop Airing2000 demonstrating its comprehensive monitoring capabilities, including particulate concentration (PM2.5, PM10, TSP), particle count (0.3µm, 0.5µm, 1.0µm), and environmental conditions (temperature, humidity).

Temtop Airing2000 internal pump-suction sensor

Image: A detailed view of the Temtop Airing2000's internal pump-suction sensor, highlighting its advanced optics and wide particle size detection capabilities.

5. Setup

5.1 Initial Charging

Before first use, fully charge both the PMD371 and Airing2000 devices. Connect the provided USB charging cables to the respective devices and plug them into the power adapters. A full charge typically takes 3-4 hours. The battery indicator on the screen will show charging status.

5.2 Powering On/Off

5.3 Basic Settings

Upon first power-on, you may need to set the date, time, and preferred units. Navigate through the menu using the arrow buttons and confirm selections with the OK button.

6. Operating Instructions

6.1 Taking Measurements with PMD371

  1. Placement: Position the PMD371 in the area you wish to monitor. Ensure the air inlet is unobstructed.
  2. Start Measurement: Press the START/STOP button to begin continuous monitoring. The screen will display real-time particle counts and environmental data.
  3. Interpreting Readings:
    • Particle Counts: Displays the number of particles per liter for various sizes (0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm).
    • PM2.5/PM10: Shows the concentration of particulate matter in micrograms per cubic meter (µg/m³).
    • Temperature/Humidity: Displays ambient temperature and relative humidity.
  4. Stop Measurement: Press the START/STOP button again to pause or stop monitoring.
  5. Data Logging: The device automatically logs data. You can access historical data through the menu.
Temtop PMD371 display showing particle count data

Image: The Temtop PMD371's screen displaying detailed particle count data for various sizes (0.3µm, 0.5µm, 0.7µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm) and PM2.5/PM10 concentrations.

6.2 Taking Measurements with Airing2000

  1. Placement: Hold the Airing2000 or place it in the desired monitoring location. Ensure the air inlet is clear.
  2. Start Measurement: The device typically starts measuring automatically upon power-on. Observe the real-time readings on the display.
  3. Interpreting Readings:
    • PM2.5/PM10/TSP: Displays concentrations of various particulate matters.
    • HCHO: Shows formaldehyde concentration.
    • Temperature/Humidity: Displays ambient temperature and relative humidity.
  4. Data Management: Use the navigation buttons to review historical data or adjust settings.

6.3 Data Transfer and Analysis

Both devices support data export. Connect the devices to a computer using the provided USB cables. The devices will appear as a removable storage device, allowing you to access logged data files (e.g., CSV format) for further analysis using spreadsheet software.

7. Maintenance

7.1 Cleaning

7.2 Storage

7.3 Calibration

The devices are factory calibrated. For professional applications requiring high accuracy, periodic re-calibration by authorized service centers is recommended. Refer to Temtop's official website or contact customer support for calibration services.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Low battery; device malfunction.Charge the device fully. If problem persists, contact support.
Inaccurate readings.Sensor obstruction; environmental interference; need for calibration.Ensure air inlets are clear. Move away from strong air currents or dust sources. Consider professional calibration.
Screen is blank or frozen.Software error; low battery.Recharge the device. Perform a hard reset (refer to specific device manual for button combination, usually holding power for 10+ seconds).
Cannot connect to computer.Faulty USB cable; driver issue; device not in data transfer mode.Try a different USB cable or port. Ensure the device is powered on and in data transfer mode if applicable.

9. Specifications

9.1 Temtop PMD371 Particle Counter

9.2 Temtop Airing2000 Particulate Monitor

10. Warranty and Support

10.1 Warranty Information

Temtop products typically come with a standard manufacturer's warranty covering defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official Temtop website for specific warranty terms and conditions. Keep your purchase receipt as proof of purchase.

10.2 Customer Support

For technical assistance, troubleshooting, or service inquiries, please contact Temtop customer support:

When contacting support, please have your product model number (PMD371 & Airing2000) and purchase date ready.

Related Documents - PMD371 & Airing2000 Bundle

Preview Temtop LKC-1000 Series Air Quality Monitor User Manual
User manual for the Temtop LKC-1000 Series Air Quality Monitor, detailing its functions, specifications, operation, and maintenance.
Preview Temtop P100/M100 Air Station User Manual: Comprehensive Air Quality Monitoring
User manual for the Temtop P100 and M100 Air Stations. Learn about monitoring PM2.5, PM10, CO2, temperature, and humidity with detailed explanations, specifications, and operational guides.
Preview Temtop PMD 371 Particle Counter User Manual
Comprehensive user manual for the Temtop PMD 371 particle counter. This guide covers device operation, settings, calibration, maintenance, troubleshooting, specifications, and warranty information for accurate air quality monitoring.
Preview Temtop PMS 21 Remote Particle Counter User Manual
User manual for the Temtop PMS 21 Remote Particle Counter, detailing its features, operation, settings, protocols, maintenance, specifications, and warranty information.
Preview Temtop M2000 2nd Generation Multi-functional Air Quality Detector User Manual
User manual for the Temtop M2000 2nd Generation, a multi-functional air quality detector that measures PM2.5, PM10, CO2, and HCHO. Provides detailed information on operation, specifications, and troubleshooting.
Preview Temtop P600 Laser Particle Detector: User Manual & Specifications
Comprehensive guide to the Temtop P600 laser particle detector, covering product overview, specifications, operation, health parameters, warranty, and contact information. Accurately monitor PM2.5 and PM10 air quality.