This manual provides essential information for the safe and efficient installation, operation, and maintenance of your HG Power FG-HVLSFAN150 150mm Extractor Fan. Please read thoroughly before use and retain for future reference.

Safety Information

Always observe the following safety precautions to prevent injury or damage:

  • Disconnect Power: Always ensure the power supply is disconnected before performing any installation, maintenance, or cleaning procedures.
  • Qualified Installation: Installation should be performed by a qualified electrician or competent person in accordance with local electrical codes and regulations.
  • Proper Grounding: Ensure the fan is properly grounded to prevent electrical shock.
  • Avoid Obstructions: Do not block the air intake or exhaust vents.
  • Indoor Use Only: This fan is designed for indoor use in specified environments.
  • Keep Dry: Do not expose the fan to water or excessive moisture during operation.

Product Features

The HG Power FG-HVLSFAN150 Extractor Fan offers the following key features:

  • High Performance Ventilation: Equipped with a durable copper motor for quiet and efficient air extraction, effectively eliminating odors and moisture.
  • Durable Construction: Made from high-quality metal (stainless steel) for longevity and resistance to deformation.
  • Integrated Check Valve: Features a backdraft damper that automatically opens and closes with airflow, preventing the entry of insects, dust, and rodents.
  • Versatile Application: Suitable for continuous or regular ventilation in various indoor spaces such as bathrooms, kitchens, offices, workshops, garages, attics, and basements.
  • Easy Maintenance: Designed with a removable structure to facilitate regular cleaning of dust and oil residue, extending the fan's service life.
Diagram showing air intake and outlet of the HG Power Extractor Fan, highlighting 7 stainless steel blades, uniform air supply, pure copper motor, and low noise operation.

Figure 1: Airflow diagram and key components of the HG Power Extractor Fan.

Specifications

Product parameter diagram showing voltage, frequency, diameter, hole size, power, air flow, speed, noise, material, and panel size of the HG Power Extractor Fan.

Figure 2: Technical specifications and dimensions.

SpecificationValue
Model NumberFG-HVLSFAN150
Diameter150 mm (6 inches)
Power38 W
Voltage220-240 V
Frequency50 Hz
Air Flow Capacity525 m³/h
Speed2800 RPM
Noise Level55 Decibels
MaterialMetal (Stainless Steel blades)
Product Dimensions (D x W x H)13.7D x 19W x 19H cm
Wall Opening Size (Recommended)153-160 mm
Special Features2.5m power cable, EU plug, Rocker switch, Check valves

Installation Instructions

Follow these steps for proper installation of your extractor fan:

Diagram showing the working and closed states of the backdraft damper. A note advises vertical installation for best results and avoiding ceiling mounting.

Figure 3: Backdraft Damper operation and installation orientation. For optimal performance, install the fan vertically. Ceiling mounting is not recommended as it may affect the backdraft damper's function.

Four-step installation guide for the HG Power Extractor Fan. Step 1: Drill a hole (153-160mm). Step 2: Insert fan, ensuring check valve is vertical. Step 3: Mark and install screws. Step 4: Connect power.

Figure 4: Step-by-step installation guide.

  1. Prepare the Opening: Drill a hole in the wall with a recommended size of 153-160 mm. Ensure the chosen location allows for proper ventilation and access for maintenance.
  2. Insert the Fan: Carefully insert the extractor fan into the prepared opening. Ensure the check valve (backdraft damper) remains in a vertical orientation for proper function.
  3. Secure the Fan: Mark the bolt hole positions on the wall. Drill pilot holes if necessary, then install the screws to securely fasten the exhaust fan to the wall.
  4. Connect Power: Once the fan is securely mounted, connect the power supply using the provided EU plug. Ensure the connection is firm and safe.

Note: For best results and proper function of the backdraft damper, vertical wall installation is recommended. Ceiling mounting may require dismantling the check valve, which could affect its ability to prevent backdrafts, insects, and dust.

Operating Instructions

The HG Power FG-HVLSFAN150 Extractor Fan is designed for straightforward operation:

  • Power On/Off: Connect the fan to a suitable power outlet. Use the integrated rocker switch on the power cable to turn the fan ON or OFF.
  • Airflow: When the fan is operating, it will draw air from the indoor space and expel it outdoors. The backdraft damper will automatically open to allow airflow and close when the fan is off to prevent unwanted ingress.

Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your extractor fan:

  • Disconnect Power: Always disconnect the fan from the power supply before any cleaning or maintenance.
  • Regular Cleaning: It is recommended to clean dust and oil residue from inside the fan and its blades regularly. The removable design facilitates this process.
  • Exterior Cleaning: Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Check for Obstructions: Periodically check the intake and exhaust vents for any blockages that might impede airflow.

Troubleshooting

If you encounter issues with your HG Power Extractor Fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn onNo power supply; Rocker switch is off; Loose connection.Check if the fan is plugged in; Ensure the rocker switch is in the 'ON' position; Verify power outlet functionality; Check for secure electrical connections.
Reduced airflow or poor extractionFan blades or vents are dirty/obstructed; Backdraft damper is stuck.Disconnect power and clean fan blades and vents; Ensure the backdraft damper moves freely.
Excessive noise during operationLoose mounting screws; Debris in fan; Damaged blades.Ensure all mounting screws are tightened; Disconnect power and inspect for debris, remove if found; If blades are damaged, contact support.
Backdraft damper not closing properlyDebris obstructing damper; Incorrect installation orientation (e.g., ceiling mount without modification).Disconnect power and clear any debris from the damper; Ensure the fan is installed vertically as recommended.

Warranty and Support

For warranty information or technical support, please refer to the documentation provided at the point of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.

© 2024 HG Power. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.